Return to search

Avaliação das alterações dimensionais em modelos de gesso para protese total por meio de medição tridimensional em função de materiais e tecnicas de moldagem / Avaliation of dimensional changes in complete dentures stone cast by means of tri-dimensional measurements, in relation to materials and impression methods

Orientador: Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T11:55:19Z (GMT). No. of bitstreams: 1
Monteiro_WildesdaCosta_D.pdf: 6985087 bytes, checksum: dab5ef3ae95601eac48a0d542f0cf87f (MD5)
Previous issue date: 2005 / Resumo: O objetivo deste estudo foi analisar por meio de medições tridimensionais, as alterações dimensionais que ocorrem nos modelos de gesso utilizados na confecção de prótese total, em função de diferentes materiais para moldagem: silicone, alginato e godiva equalizada com alginato. Foram confeccionados 45 modelos de gesso tipo IV, (n=15) construídos a partir de moldes obtidos de um modelo padrão metálico de alumínio, onde foram colocados 7 parafusos com 3,5 mm de diâmetro, para estabelecer pontos referenciais das distâncias a serem mensuradas. Esses pontos referenciais permitiram criar segmentos para o cálculo do volume e da área gerados nas figuras representativas dos modelos de gesso, permitindo avaliar a estabilidade dimensional dos modelos em gesso por meio de medições tridimensionais. No CETEF os modelos de gesso foram submetidos às medições tridimensionais no aparelho Mitutoyo, modelo BLN 710, equipado com cabeça de medição Renishaw PH9 e apalpador TP200 com esfera de 1mm de diâmetro, para as seguintes etapas: 1- transferência das coordenadas tridimensionais para o programa Mechanical Desktop; realização dos desenhos bidimensionais; medição dos seguimentos que compõem cada figura desenhada de cada desenho; realização dos desenhos tridimensionais; cálculo do volume e da área projetada utilizando a malha de elementos finitos e confecção de uma planilha de cálculo para cada material de moldagem; tratamento estatístico dos dados e determinação matemática das variações e das coordenadas x, y e z dos comprimentos de cada um dos segmentos, dos perímetros e das áreas de cada figura dos quarenta e cinco modelos. 2- lançamento dos dados nas planilhas de cálculo; tratamento estatístico dos dados e determinação matemática das variações e das coordenadas x, y e z dos comprimentos de cada um dos segmentos, dos perímetros e das áreas de cada figura. 3- apresentação tridimensional das variações dimensionais encontradas nos modelos; transferência das variações das coordenadas do grupo de modelos de cada material, em relação ao modelo padrão, para o software de desenho 3D ¿ Mechanical Desktop; geração das figuras para visualização das variações e elaboração de relatório técnico. Os resultados foram submetidos à média matemática simples da dispersão ou variação dos dados, que é o grau no qual os dados numéricos da amostra tendem a dispersar-se em torno de um valor médio. Foi utilizado neste trabalho o cálculo do desvio padrão simples. Os moldes feitos com silicone por adição produziram modelos com menor variação dimensional (capacidade de repetitibilidade) quando comparados aos modelos obtidos com moldes de alginato e godiva equalizada com alginato. O alginato produziu modelos com grande fidelidade de cópias em função da matriz metálica / Abstract: The purpose of this study was to analyze, through three-dimensional measurements, the dimensional changes in casts of stone used to make complete dentures, in function of different materials for impression: addition reaction silicone, alginate and impression compound reline with alginate. The casts of stone type IV were made from molds obtained from a metallic standard die of aluminum. In this metallic die were put seven screws with 3,5mm diameter, to establish referential points of the measured distances. The referential points allowed creating segments
for the calculation of the area and volume in the representative drawings generated for the stone casts. The procedure allows evaluating the dimensional stability through three-dimensional measurements. In CETEF the stone die were measured with three-dimensional equipment Mitutoyo, model BLN 710, equipped with measurement head Renishaw PH9 and feeler TP200 with sphere of 1mm of diameter, for the stages: 1- Transfer of the three-dimensional coordinates for the program Mechanical Desktop; generation of the two-dimensional drawings; measurement of the segments that compose each drawing; generation of the three-dimensional drawings; projected area determination and volume calculation using the finite elements net; making of a calculation spread sheet for each impression material; statistical treatment of the data and mathematical determination of the variations in the x, y and z coordinates in the lengths of each segments, in the perimeters and in the areas of each drawing of the forty five casts. 2 - Insertion of the data in the calculation spread sheets; statistical treatment of the data and mathematical determination of the variations and in the x, y and z coordinates in the lengths of each one of the segments, in the perimeters and of the areas of each drawing. 3 - Three-dimensional presentation of the dimensional variations found in the models; transfer of the variations of the coordinates of the group of models of each material, for the software of 3D drawing ¿ Mechanical Desktop; generation of the drawings for visualization of the variations and elaboration of technical report. The results were submitted to the simple mathematics medium of the dispersion or variation of the data, that it is the degree, in which the numeric data of the sample tend to disperse around a medium value. It was used in this work the calculation of the simple standard deviation. The molds made with addition reaction silicone produced casts with smaller dimensional variation, when compared to the casts obtained with alginate or impression compound reline with alginate. The silicone presented larger capacity to repeat generated copies of the molds, from the standard die. The cast made with addition reaction silicone presented small variation among themselves when compared to the standard metallic die / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290120
Date16 May 2005
CreatorsMonteiro, Wildes da Costa
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Simonides, 1939-, Eduardo, Jose Virgilio de Paula, Seraidarian, Paulo Isaias, Mesquita, Marcelo Ferraz, Correr Sobrinho, Lourenço
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format84f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0028 seconds