Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-03-07T15:58:58Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-05-15T12:54:23Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5) / Made available in DSpace on 2014-05-15T12:54:23Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5)
Previous issue date: 2013 / Neste trabalho, são apresentados a metodologia de projeto e resultados de testes experimentais de um estabilizador de sistema de potência (ESP), implementado em um sistema de geração em escala reduzida de 10 kVA, localizado no Laboratório de Controle e Sistema de Potência (LACSPOT) da Universidade Federal do Pará (UFPA). O projeto do ESP é baseado em uma estratégia de controle robusto com ênfase em incertezas paramétricas estruturadas, as quais são tratadas com ferramentas da teoria de análise intervalar. Estas incertezas são decorrentes de mudanças do ponto de operação do sistema, que provocam variações nos parâmetros de um modelo matemático linearizado referente ao comportamento dinâmico do sistema elétrico de potência no referido ponto de operação. Para o projeto do ESP robusto intervalar, são realizados uma serie de ensaios experimentais com o propósito de estimar os parâmetros de modelos linearizados da planta, representando satisfatoriamente a dinâmica dos modos poucos amortecidos do sistema de geração interligado. O método de identificação é baseado em técnica de identificação paramétrica, baseado em mínimos quadrados. A partir de um conjunto de dados de entrada e saída, para cada ponto de operação, um modelo linear, do tipo auto-regressivo com entrada exógenos (ARX), estimado para fim de uso do projeto do ESP.
Por fim, uma série de testes experimentais é realizada no sistema de geração interligado a rede elétrica local, com o propósito de verificar a efetividade da técnica de controle robusto intervalar proposta para a sintonia do ESP. A partir da análise da função custo do sinal de erro de desvio de potência elétrica na saída do gerador síncrono e a função custo do sinal de controle do ESP comprova-se experimentalmente o bom desempenho obtido pela técnica de controle proposta em comparação com uma técnica de controle clássica. / In this paper, are presented the design methodology and the experimental test results of a power system stabilizer (PSS), implemented in a small-scale generation system of 10 kVA, located in the Control and Power System Laboratory (LACSPOT) at the Para Federal University (UFPA). The PSS design is based on a robust control strategy with emphasis on the structured parametric uncertainties, which are treated with tools of the interval analysis theory. These uncertainties are arising from the system operation point, which cause variations in the parameters of a linearized mathematical model referent on the dynamic behavior of the power electric system in the operation point. For the interval robust PSS design, are performed experimental tests with the purpose of estimating the linearized plant models parameters, representing the low damped modes dynamic of the interconnected generation system. The identification method is based on parametric identification technique based on least squares. From a set of input and output data, for each operation point, a ARX linear model is estimated with the purposed of the PSS design. Finally, a set of experimental tests is performed in the interconnected generation system, with the purpose of analyze the effectiveness of the interval robust control technique proposed to the PSS design. From the analysis of the active power deviation signal cost function at the synchronous generator terminal and the PSS control signal cost function, proves experimentally the good performance achieved by robust control technique proposed in comparison with a classic control technique.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/4972 |
Date | 12 1900 |
Creators | COSTA, Cleyson Amorim |
Contributors | BARRA JUNIOR, Walter |
Publisher | Universidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0091 seconds