Return to search

Efeito hemodinamico da sincronização eletrica biventricular prolongada no pos-operatorio de revascularização do miocardio / Hermodynamic effects of biventricular stimulation in patients at post-operative period of coronary arterybypass surgery

Orientador: Kleber Gomes Franchini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-06T19:09:29Z (GMT). No. of bitstreams: 1
Lima_JoseMarcoNogueira_D.pdf: 1108641 bytes, checksum: 52decb99b4c7eb40cf6e3df4bdda5d47 (MD5)
Previous issue date: 2006 / Resumo: O presente estudo tem como objetivo avaliar a influência da estimulação biventricular prolongada no pós-operatório de revascularização miocárdica em pacientes portadores de disfunção ventricular esquerda, FE = 40%, associada à duração do QRS menor ou igual a 130ms. Foram selecionados 21 pacientes dos quais 16 foram randomizados em dois grupos denominados: Grupo de estimulação biventricular (Grupo EBV) e Grupo Controle. Os dois grupos foram submetidos à monitorização contínua por um período de 12 horas com os seguintes parâmetros coletados: parâmetros hemodinâmicos sistêmicos (pressão arterial média, índice de resistência vascular sistêmica e temperatura), parâmetros hemodinâmicos cardíacos (débito cardíaco, índice cardíaco, índice do volume sistólico do ventrículo esquerdo e freqüência cardíaca) e parâmetros hemodinâmicos pulmonares (pressão em cunha de capilar pulmonar, pressão venosa central e índice de resistência vascular pulmonar). Para análise dos resultados foram empregados o teste t de Student, teste de Wilcoxon, teste exato de Fisher, teste de Wilks e MANOVA. A sincronização obtida através da estimulação biventricular sob captação atrial (sinusal) aumentou o índice cardíaco em conseqüência do aumento do volume sistólico. Observou-se também uma redução significativa da resistência vascular sistêmica em comparação com os pacientes não estimulados. Esses efeitos permaneceram nas 6 horas que se seguiram após a parada da estimulação no Grupo EBV. Não houve diferença estatisticamente significativa na pressão arterial média entre os grupos. O grupo estimulado apresentou uma menor pressão em cunha de capilar pulmonar do que o grupo controle durante o período da estimulação. Podemos concluir que a estimulação biventricular produziu nesses pacientes uma melhora do desempenho sistólico do ventrículo esquerdo por restaurar a coordenação da contratilidade cardíaca em conseqüência da sincronização independente da variável freqüência cardíaca e duração do QRS / Abstract: The present study aims to evaluate the influence of lengthened biventricular stimulation on the post-surgical period of myocardical revascularization in patients that carry left ventricular dysfunction, FE = 40%, associated to QRS endurance equal to or less than 130 ms. From a selection of 21 patients, 16 of which were randomized in 2 groups named: Biventricular Stimulation Group (EBV Group) and Control Group. Both groups have been submitted to a 12-hour continuous monitoring period, with the following parameters being collected: systemic hemodynamic parameters (mean arterial pressure, systemic vascular resistance index and temperature), cardiac hemodynamic parameters (cardiac output, cardiac index, left ventricle stroke volume index and heart rate) and pulmonary hemodynamic parameters (pulmonary artery wedge pressure, central venous pressure and pulmonary vascular resistance index). For the analysis of the results we have applied the Student's t test, Wilcoxon rank-sum test, Fisher's exact test, Wilks' test and MANOVA. The synchronization obtained through biventricular stimulation under atrial sense increased the cardiac index, as a consequence of the increased systolic volume. A significant reduction of systemic vascular resistance has also been observed, in comparison to that of the non-stimulated patients. These effects have endured for the 6-hour period that succeeded the interruption of the stimulation in the EBV Group. There was no statistically significant difference in the average blood pressure between the groups. The stimulated group presented a lower pulmonary artery wedge pressure than that of the control group over the stimulation period. We can concluded the biventricular stimulation has produce an improvement on the systolic performance as the left ventricular do the restoration of the ventricular contractibility as a consequence of a synchronization that the not depend the frequency and the QRS lasting / Doutorado / Medicina Experimental / Doutor em Fisiopatologia Medica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/310236
Date15 March 2006
CreatorsLima, Jose Marco Nogueira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Franchini, Kleber Gomes, 1961-, Junior, Rubens Fazan, Filho, Dalmo Correia, Bittencourt, Luiz Antonio Kannebley, Almeida, Eros Antonio de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Fisiopatologia Médica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format84f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds