Avaliação de conforto térmico em ambientes naturalmente ventilados : um exemplo em restaurante universitário / Evaluation of thermal comfort in naturally ventilated environments : an example in university restaurant

Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T04:17:09Z (GMT). No. of bitstreams: 1
Coutinho_BrendaRodrigues_M.pdf: 4158549 bytes, checksum: 3a4377f2afd89c8a67f1e657243a94e6 (MD5)
Previous issue date: 2014 / Resumo: No Brasil, a avaliação do conforto térmico é uma área que tem sido cada vez mais abordada pelos pesquisadores. As condições de conforto são regulamentadas por normas técnicas nacionais e internacionais, as quais indicam os parâmetros para que os usuários estejam em condição de conforto em função dos valores-limite de temperatura do ar, umidade do ar e velocidade do ar. Estes padrões também estão relacionados ao tipo de atividade exercida e à vestimenta utilizada. Os índices PMV ¿ Predicted Mean Vote e PPD ¿ Predicted Percentage of Dissatisfied adotados pela norma ISO 7730 (2005), são utilizados como meio de avaliação para o conforto térmico para ambientes termicamente moderados. A versão da ASHRAE 55 do ano de 2010 se baseia nas mesmas condições determinadas pela ISO 7730, mas incorporou pesquisas relevantes como a de DeDear, Brager e Cooper (1997), como o modelo adaptativo, o qual relaciona as temperaturas internas de conforto ao clima externo para ambientes naturalmente ventilados. Ambas as normas citadas não utilizaram dados provenientes de medições em restaurantes onde há uma carência literária sobre o assunto. Além disso, trabalhos como o de Humphreys (1976), Voltani (2009) e Maiti (2014) mostraram discrepâncias entre os votos de sensação térmica real e prevista, A proposta deste trabalho é a realização de um estudo do conforto térmico em dois restaurantes da Unicamp, Restaurante Universitário (RU) e Restaurante da Saturnino (RS), em Campinas ¿ SP, fazendo uma comparação entre as sensações térmicas reais dos trabalhadores e usuários com o modelo PMV e o modelo adaptativo. Para a realização deste trabalho foi feita a escolha do lugar, contextualização do ambiente aonde se localizam os restaurantes, coletou-se as variáveis ambientais simultaneamente em todos os pontos em cada restaurante e estimou-se as variáveis pessoais no momento das medições de acordo com as normas ISO. Simultaneamente foram aplicados questionários sobre a sensação de conforto e preferências térmicas da população pesquisada. Após esta etapa, realizaram-se análises comparativas entre os resultados gerados pelo método PMV e adaptativo e os votos da sensação térmica real. Utilizou-se análise Probit para avaliar os dados obtidos estabelecendo uma correlação entre as normas e a sensação real. Neste trabalho foram coletadas mais de 1400 entrevistas e mais de 750 medições das variáveis ambientais. Foi feita uma comparação das porcentagens de satisfação e insatisfação dos entrevistados. Além disso, calcularam-se as temperaturas de neutralidade térmica. As conclusões mostraram que as faixas de conforto térmico e temperatura de neutralidade foram próximas as recomendadas pelas normas nos pontos dos usuários. Nos pontos dos funcionários houve divergência entre a temperatura de neutralidade da ISO 7730 (2005) obtida por questionário e a calculada por análise Probit, todavia a maior discrepância encontrada foi entre os resultados analisados segundo as normas ISO 7730 (2005) e ASHRAE 55 (2010). Outra conclusão foi que as temperaturas internas do RS foram superiores as do RU nos pontos dos usuários no verão e o modelo proposto pela ISO 7730 (2005) não foi adequado para avaliar os índices de conforto no RS, pois ultrapassava seu limite máximo de desconforto pelo calor / Abstract: In Brazil, the evaluation of thermal comfort is a subject that has been increasingly addressed by researchers. Comfort conditions are regulated by national and international technical standards, which indicate the parameters for users are in a comfort condition in the limit values of air temperature, air humidity and air velocity. These standards are also related to the kind of activity and used clothing. The PMV rates (Predicted Mean Vote) and PPD rates (Predicted Percentage of Dissatisfied) adopted by ISO 7730 in 2005, are used as a way to evaluate the thermal comfort for moderate thermal environments. The version of ASHRAE 55, in 2010, is based on the same conditions determined by ISO 7730, but incorporated some relevant research as the De Dear, Brager and Cooper's (1997) as adaptive model, which relates comfort internal temperatures with external climate for naturally ventilated environments. Both standards cited did not use data from restaurants measurements which there is a literature shortage about the subject. Moreover, works such as Humphreys (1976), Voltani (2009) and Maiti (2014) showed discrepancies between actual and expected thermal sensation votes. The purpose of this research is to conduct a thermal comfort study in the two Unicamp¿s restaurants, University Restaurant (RU) and the Saturnino Restaurant (RS), in Campinas - SP, making a comparison between the actual thermal sensations of workers and users with the PMV model and the adaptive model. In order to do this work, it was chosen the place, it was made the context analysis of the environment where restaurants are located, it was collected environmental variables simultaneously at all points in every restaurant and it was estimated personal variables at the time of the measurements according to the ISO standard. Simultaneously it was applied questionnaires about the comfort feeling and thermal preferences of the population surveyed. After this step, there were comparative analysis among the results generated by PMV and adaptive method and the actual thermal sensation votes. Probit analysis was used to evaluate the data obtained by establishing a correlation between the rules and the real feel. This research collected over 1400 questionnaires interviews and more than 750 measurements of environmental variables. A comparison of the percentages of satisfaction and dissatisfaction of respondents was made. Furthermore, were calculated the thermal neutrality temperatures. The findings showed that the ranges of thermal comfort and neutrality temperature were close to the recommended by the standards in user¿s points. In the employees points there was disagreement between the obtained ISO 7730 (2005)¿s neutrality temperature by questionnaire and the calculated by Probit analysis, nevertheless the biggest discrepancy was found between the results analyzed according to the ISO 7730 (2005) and ASHRAE 55 standards (2010). Another conclusion was that the internal temperatures of RS were higher than those in RU¿s users points in the summer and the ISO 7730 (2005)'s model was not adequate to evaluate the comfort level in RS, because exceeded its maximum heat discomfort / Mestrado / Arquitetura, Tecnologia e Cidade / Mestra em Arquitetura, Tecnologia e Cidade

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258060
Date08 August 2014
CreatorsCoutinho, Brenda Rodrigues, 1987-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Labaki, Lucila Chebel, 1943-, Bertoli, Stelamaris Rolla, Bueno-Bartholomei, Carolina Lotufo
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura, Tecnologia e Cidade
Source SetsIBICT Brazilian ETDs
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format145 p. : il., application/pdf