Acoustic travel-time measurement is a method for remote sensing of the atmosphere. The temperature-dependent sound speed as well as the flow field can be detected by measuring the travel time of a defined acoustic signal between a sound source and a receiver when the distance between them is known. In this study the properties of the flow field are reconstructed using reciprocal sound rays to separate the directionindependent sound speed from the effective sound velocity including the flow velocity component in direction of the sound path. The measurements are taken on a horizontal scale of about 2 m x 2 m. By measurements in interiors, where no flow of air exists, the temperature can be determined with an accuracy of 0.6°C and the flow component in direction of the sound path with an accuracy of 0.3 m/s. If flow of air exists the measurements gets complicated because the phase shifts, which have been detected by the receivers, cannot be corrected like it was possible without the influence of flow.