Background: Parameters of carotid atherosclerosis dynamic contrast-enhanced MRI (DCE-MRI) are associated with stroke risk indices, but studies have only evaluated symptomatic arteries. I hypothesized that DCE-MRI parameters are different between carotid atherosclerotic plaques at high and low risk for precipitating ischemic stroke. Methods: High and low risk carotid plaques undergoing nonmodel-based DCE-MRI (n=18) were compared using two independent schema: 1) clinical standard (high risk defined as ipsilateral stroke/TIA <1 week old or stenosis >70%); 2) MRI standard (high risk defined as presence of intraplaque hemorrhage [IPH]). Results: IPH-positive plaques (n=9) exhibited greater area under the curve, early and late enhancement rate, and peak enhancement than IPH-negative plaques (n=9) (p<0.05 for all). High (n=8) and low (n=7) risk plaques defined by clinical criteria were not differentiated by any DCE-MRI parameters. Conclusions: Nonmodel-based DCE-MRI discriminates high versus low risk carotid plaque based on the presence of IPH, but not by clinical criteria.
Identifer | oai:union.ndltd.org:TORONTO/oai:tspace.library.utoronto.ca:1807/31326 |
Date | 14 December 2011 |
Creators | MacLean, David Bailey |
Contributors | Mikulis, David J. |
Source Sets | University of Toronto |
Language | en_ca |
Detected Language | English |
Type | Thesis |