Return to search

Influencia dos materiais de moldagem e das tecnicas de transferencia em implantes, na precisão dimensional linear dos modelos de gesso

Orientadores: Saide Sarckis Domitti, Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T01:33:26Z (GMT). No. of bitstreams: 1
Goiato_MarceloCoelho_D.pdf: 3053026 bytes, checksum: c84578d7c293c442c5213a848804985b (MD5)
Previous issue date: 1997 / Resumo: O propósito deste estudo foi verificar a alteração dimensional linear em modelos de gesso à partir de reproduções de uma matriz metálica com 4 transferentes para implantes. Os modelos foram confeccionados utilizando-se três materiais de moldagem e três técnicas de moldagem de transferência. Os materiais de moldagem utilizados foram: silicona por adição(Express); silicona por condensação(Optosil-Xantopren) e poliéter (Impregum F). As técnicas de moldagem de transferência adotadas foram: transferente com "coping" metálico com resina "Duralay" esculpida em forma quadrada; técnica com o transferente e "coping" metálico unidos com resma "Duralay"; e técnica com transferentes cónicos. Após confeccionada a matriz metálica, representando uma maxila desdentada total, foram fixados quatro implantes em posições simétricas, sendo dois em cada semi-arco, utilizando quatro transferentes cilíndricos com faces oclusais lisas e polidas, e ponto central geométrico bem definido, os quais serviram para a realização das medidas originais entre os transferentes rosqueados na matriz metálica. Os ensaios foram realizados de acordo com a especificação na 19 da A.D.A.38 e Revisão da I.S.O. 4823/198439. Foram utilizadas 45 moldeiras individuais para a realização das moldagens. Para os ensaios de alteração dimensional linear foram confeccionados cinco moldes para cada material de moldagem com uma das técnicas de transferência. Os moldes foram removidos da matriz 3 minutos além do tempo recomendado pelos fabricantes e imediatamente preenchidos com gesso pedra mellhorado, sobre vibração. As leituras dos valores das alterações dimensionais lineares foram realizadas num microscópio comparador CARL ZEISS (Alemanha), nas medições com os transferentes cilíndricos na matriz metálica. Os resultados obtidos foram submetidos a analise de variância e ao teste de Tukey, indicaram que as três técnicas de moldagem de transferência não exerceram influência sobre a alteração dimensional, assim como não houve diferença estatisticamente significativa (p<0,05) na alteração dimensional dos modelos de gesso, obtidos em moldes de sílicona por adição (Express) e poliéter (Impregum F); já, a silicona por condensação (Optosil-Xantopren) mostrou contração estatisticamente significativa em algumas situações / Abstract: The object of the study was to verify the linear dimensional changing in reproductions of metallic matrix with 4 pins of transference to implants osseointegrated performed with three impressions materials and three techniques of impression transference. The impression materials were: silicone by addition (Express); silicone by condensation (Optosil-Xantopren) and one polyether (Impregum F). The techniques of impression transference used were : metalic coping pin with Duralay resin sculpted in square shape; pin transference technique and metallic coping joined with duralay resin; and pins tapered transference technique. After the metallic matrix was made, a complete toothless jaw, four implants were set in simetric positions, being two in each semi-arch. It was used four cylindric pins with its smooth oclusals fees polished, with geometrical central point well defined, which served as the accomplisliment of the original measures between the pins screwed on the metalhc matrix. The worked were acomplished according to the recommendation of the specification number 19 of. A.D.A38. and Review of LS.O. 4823/198439. It was used 45 custom trays, for the accomplishment of the impression. For the linear dimensional changing test were made five molds for each impression material with one of the pins transference technique. The molds were removed from the matrix 3 minutes after that recommended by the manufacturers and imediatelly filled with improved dental stone, with vibration. The reading of the linear dimensional changing was made in a comparer microscope LEITZ (Germany), in the same conditions described on the linear dimensional changing test. The results were applicaded Tukey test, indicated that the three techniques of impression transference didn't have any influence on the dimensional changing, however the results showed that there was no significant statistic difference (p>0,05) on the dimensional changing of the casts, obted in molds of silicone by addition (Express) and the polyether (Impregum F); except to the silicone by condensation (Optosil-Xantopren) in a few situations / Doutorado / Protese / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289946
Date10 December 1993
CreatorsGoiato, Marcelo Coelho
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Consani, Simonides, 1939-, Domitti, Saide Sarckis, 1932-2016
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format99 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0018 seconds