Return to search

Valor do teste de dosagem do Dímero - D plasmático no diagnóstico do tromboembolismo venoso agudo / Value of measure plasmatic D Dimer test to diagnosis of the acute thrombolism venous

Introdução: A doença tromboembólica é um distúrbio complexo multicausal com sinais e sintomas inespecíficos, confundindo-se com outras enfermidades. Devido à sua gravidade buscam-se estratégias objetivando obter um diagnóstico precoce. O teste de dosagem do dímero - D plasmático parece ser uma alternativa para exclusão do diagnóstico de tromboembolismo venoso agudo. Objetivo: Avaliar o valor do teste de dosagem de dímero - D plasmático, utilizando o método Enzyme Linked Fluorescent Assay (ELFA), na rotina diagnóstica de tromboembolismo venoso agudo. Métodos: Em 89 pacientes com sinais e sintomas sugestivos de tromboembolismo pulmonar e/ou trombose venosa profunda foram realizadas dosagens do dímero - D pela técnica ELFA no equipamento VIDAS® - BioMérieux. Foram calculados os valores da sensibilidade, especificidade, valores preditivos positivo e negativo e acurácia do teste, bem como a curva ROC da amostra estudada. Todos os pacientes foram submetidos a exame por imagem para confirmação do evento tromboembólico agudo. Foi calculado o índice kappa para analisar o resultado do teste dímero - D versus resultados de exames por imagem. Resultados: Entre os 89 pacientes estudados (média de idade 54,3 anos; 51 mulheres), 36 (40,4%) apresentaram TEV e 53 não apresentaram trombose aguda (59,6%). Entre os pacientes sem trombose aguda 15 (28,3%) apresentaram resultado de dímero - D negativo. Todos pacientes com trombose apresentaram resultado de dímero - D positivo. O teste apresentou sensibilidade de 100%; especificidade de 28,3%; valor preditivo positivo de 48,6%; valor preditivo negativo de 100% e exatidão de 57,3%. A ASC para a amostra total estudada foi igual a 0,734, indicando que o teste é um bom preditor de trombose aguda. O valor do índice kappa para a amostra total foi igual a 0,24 (p<0,001), indicando uma concordância fraca entre dímero - D e diagnóstico confirmatório de trombose. Conclusão: A dosagem do dímero - D pelo método ELFA foi capaz de excluir o diagnóstico de tromboembolismo venoso agudo nessa amostra estudada. Os resultados obtidos nessa amostra estudada permitiram concluir que o uso do teste dímero - D em pacientes com suspeita de tromboembolismo venoso revelou alta sensibilidade no diagnóstico dessa enfermidade. / Introduction: The thromboembolic disease is a multicausal complex disturb with signals and symptoms that confusing itself with other diseases. Because its gravity strategies search objecting to get a faster diagnosis. The measure plasmatic D dimer test seems to be an alternative for exclusion of the diagnostic of acute venous thromboembolism. Objectives: To evaluate the value of the measure plasmatic D dimer test, using the method Enzyme Linked Fluorescent Assay (ELFA), in the diagnostic of acute venous thromboembolism. Methods: In 89 patients with signals and symptoms suggestive of pulmonary thromboembolism and/or deep vein thrombosis had been carried through measure D dimer by technique ELFA equipment VIDAS® - BioMérieux. The values of sensibility, accuracy specificity, predictive values positive and negative and of the test had been calculated, as well as curve ROC of the sample studied. All the patients had been submitted the image exams for the confirmation of the acute thromboembolism event. It was calculated kappa ratio to compare D dimer test results with image exams results. Results: Between 89 studied patients (mean of age 54.3 years; 51 women), 36 (40.4%) they had presented and 53 had not presented acute thrombosis (59.6%). It enters the patients without acute thromboembolism 15 (28.3%) had presented resulted negative of D dimer. All patients with thrombosis had presented resulted positive of D dimer. The test presented 100% sensibility; 28.3% of specificity; positive predictive value was 48.6%; 100% of negative predictive value and accuracy value was 57.3%. The area under the curve (AUC) to total sample studied was 0.734, it was showed that the test have a good prediction to acute thrombosis. The kappa ratio value was 0.24 (p<0.001) showing a bad concordat n to thrombosis diagnostic. Conclusion: The measure of D dimer by method ELFA was able to exclude the diagnostic of acute venous thromboembolism in this sample studied. The results obtained in this sample studied let to conclude that the D dimer test in patients with suspected of acute thromboembolism presented high sensibility to diagnostic of this disease.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-13022008-100326
Date29 October 2007
CreatorsLuciana Pereira de Almeida de Piano
ContributorsSilvia Helena Gelas Lage Pasqualucci, Roberto Abi Rached, Fernando Augusto Alves da Costa, Pedro Fernandes Lara, Neuza Helena Moreira Lopes, Célia Maria Cássaro Strunz
PublisherUniversidade de São Paulo, Cardiologia, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds