Orientadores: Gilberto De Martino Jannuzzi, Elizabeth Ferreira Cartaxo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-12T11:39:09Z (GMT). No. of bitstreams: 1
Silva_VladimirFreitasPaixaoe_M.pdf: 2710715 bytes, checksum: bbdac7d8cccb290379966ac18bb1f00d (MD5)
Previous issue date: 2008 / Resumo: Esta dissertação tem como objetivo avaliar os impactos da redução do consumo de energia elétrica em Manaus através de medidas de eficiência energética em climatização residencial. A escolha da correta orientação geográfica, a pintura das paredes e dos telhados com cores claras, a inclusão de isolamento térmico EPS (Isopor) no forro, a inclusão de isolamento reflexivo por baixo do telhado e a abertura de áticos, foram medidas de eficiência energética aplicadas na residência do estudo de caso para avaliar a redução das cargas térmicas dos seus respectivos recintos internos (quartos). Outra medida de eficiência energética utilizada foi a substituição de condicionadores de ar do tipo janela de baixa eficiência por equipamentos de alta eficiência. As estimativas das cargas térmicas resultantes das aplicações das medidas de eficiência energética foram obtidas por meio da utilização do software CARRIER E20-II, HAP, v4.33., cuja licença de uso é encontrada à venda no mercado nacional. Definidas as cargas térmicas dos quartos, foram especificados os condicionadores de ar do tipo janela que seriam usados na climatização desses ambientes. O emprego combinado dessas medidas de eficiência energética permitiu que fossem quantificadas as respectivas economias de consumos e de redução de demanda de energia elétrica e seus efetivos impactos sobre o Sistema Manaus. / Abstract: This thesis aims to assess the impacts of electricity consumption reduction in Manaus through energy efficiency measures applied in home climatization. The choice of correct geographical orientation, walls and roofs painting with clear colors, the inclusion of thermal insulation EPS (Styrofoam) in the lining, the inclusion of reflective insulation under the roof, attic opening and closing, are energy efficiency measures applied in the case study residence to reduce the thermal loads on their respectives rooms. Another efficiency measure used was the replacement of low efficiency window air-conditioners for high-efficiency ones. The resulting thermal loads from the application of these measures were obtained through the use of software CARRIER E20-II, HAP, v4.33., whose using license is found for sale on the domestic market. Defined the rooms thermal loads, the cooling capacities of the window air-conditioners were specified to be used in the cooling of these environments. The combined employment of these energy efficiency measures has allowed quantify their electric energy consumption economies and demand reductions and its impacts on the Manaus System. / Mestrado / Planejamento de Sistemas Energeticos / Mestre em Planejamento de Sistemas Energéticos
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/265049 |
Date | 11 March 2008 |
Creators | Silva, Vladimir Freitas Paixão e |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Cartaxo, Elizabeth Ferreira, Jannuzzi, Gilberto de Martino, 1955-, Silva, Vanessa Gomes da, Pereira, José Tomaz Vieira |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Planejamento de Sistemas Energéticos |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 130 p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0095 seconds