Return to search

Levantamento do espectro de nêutrons em torno do Ciclotron do IEN/CNEM - calibração de um dosímetro pessoal de nêutrons

Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-08-30T18:10:56Z
No. of bitstreams: 1
PATRICIA WIELAND M.pdf: 1806623 bytes, checksum: a594345ae62a5497ea23b2f6a4d9e38f (MD5) / Made available in DSpace on 2017-08-30T18:10:56Z (GMT). No. of bitstreams: 1
PATRICIA WIELAND M.pdf: 1806623 bytes, checksum: a594345ae62a5497ea23b2f6a4d9e38f (MD5)
Previous issue date: 1991 / A resposta dos dosímetros de nêutrons de albedo é bastante dependente da energia dos nêutrons incidentes e a sua calibração é feita em campo, nos locais onde os trabalhadores estão expostos. Este trabalho envolve o estudo, análise e aplicação de técnicas de medida de nêutrons, tanto para obtenção de informações sobre o espectro presente, quanto para a medida de dose equivalente em vários locais de trabalho no cíclotron do Instituto de Engenharia Nuclear. Com o objetivo principal da calibração efetiva do dosímetro de albedo usado no Brasil. As esferas de Bonner e a técnica de ativação de folhas foram utilizadas para o levantamento do espectro de nêutrons e a dose equivalente foi determinada com a monoesfera de albedo do Kernforschungzentrum Karlsruhe e com detectores proporcionais de BF3 e 3HE e detector de cintilação de 6LiL.
O dosímetro de albedo nacional foi calibrado através da técnica da monoesfera de albedo, que foi a que mais se adaptou às variações do campo de nêutrons do cíclotron. Seu desempenho foi comparado com o do dosímetro de albedo usado na Alemanha. Foram encontrados fatores de calibração para serem aplicados rotineiramente, ou seja, quando os trabalhadores estão protegidos pelas blindagens de concreto e para situações de acidentes radiológicos. Caso algum trabalhador seja irradiado dentro das cavernas do cíclotron. / The albedo neutron dosimeter is calibrated directly at the work place due to its high energy dependence. This thesis deals with the study, analysis and application of neutron measurement techniques in order to obtain information about the neutron spectrum and neutron dose equivalent at several representative working places of the cyclotron laboratory of the Nuclear Engineering Institute (IEN). These data are employed mainly in the calibration of the brazilian albedo neutron dosimeter. Bonner spheres and foil activation were used in neutron spectra measurements and the neutron dose equivalents
were measured with the single sphere albedo technique. BF3 and 3He proportional detectors and 6LiI scintillation detector were also used in these measurements. The single sphere technique turned out to be more appropriate for neutron dosimeter for calibrating the albedo dosimeter in the varying fields of the cyclotron. Calibration factors were found for routine applications, when the workers are protected by shielding
and for radiological accident applications, in the case that a worker is exposed inside the cyclotron room. In all situations the performance of the brazilian albedo dosimeter is compared with that of the german albedo dosimeter.

Identiferoai:union.ndltd.org:IBICT/oai:carpedien.ien.gov.br:ien/1885
Date January 1991
CreatorsWieland, Patricia, Instituto de Engenharia Nuclear
ContributorsLipszteln, Joyce Landmann, Barros, Solange M. C., Crispin, Vergínia Reis, Rosa, Luiz Antonio Ribeiro da, Lipsztein, Joyce Landmann
PublisherInstituto de Engenharia Nuclear, Programa de Pós-Graduação do Instituto de Física, IEN, Brasil, Universidade Federal do Rio de Janeiro
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional do IEN, instname:Instituto de Engenharia Nuclear, instacron:IEN
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds