Return to search

Avaliação in vitro da resistência estrutural em dentes fragilizados utilizando reforços intra-radiculares

Made available in DSpace on 2015-01-26T13:21:31Z (GMT). No. of bitstreams: 0
Previous issue date: 2002-05-07Bitstream added on 2015-01-26T13:30:16Z : No. of bitstreams: 1
000153365.pdf: 4243096 bytes, checksum: 4ac8a630a1606f01e62807e3baafb495 (MD5) / Dentes com rizogênese incompleta quando sofrem trauma com conseqüente necrose pulpar permanecem com suas paredes dentinárias finas e fragilizadas, tornando-se mais suscetiveis a reincidências de fraturas. A proposta deste trabalho foi avaliar através do teste de compressão a resistência à fratura de dentes bovinos fragilizados que receberam reforços intra-radiculares com resina composta ou pino de fibra de zircônia. Para tanto, utilizou-se 56 dentes bovinos, os quais tiveram suas coroas seccionadas padronizando o tamanho das raízes em 30mm. Os dentes foram divididos em quatro grupos experimentais (14 dentes} e, com exceção do grupo 04 (Controle negativo), todos os canais radiculares foram preparados biomecanicamente até o instrumento de nº 80 e alargados com brocas Gates-Glidden nos 3, 4, 5 e 6 até 20mm de profundidade. A porção coronária foi alargada com broca diamantada tronco cônica nº 721 até a junção cemento-esmalte vestibular e, com broca diamantada tronco cônica nº 716, realizou-se a fragilização das paredes dentinárias do canal radicular a 20mm de profundidade, deixando aproximadamente 2mm de espessura em cada parede. Após, as raízes foram divididas em grupos: grupo 01-receberam reforço intra-radicular com resina composta, fotopolimerizada com o auxílio do sistema Luminex , seguida da obturação do canal; grupo 02-obturação do canal deixando os 10mm apicais com material obturador, e reforço intra-radicular com pino de fibra de zircõnia cimentado com cimento resinoso; o grupo 03-(Controle positivo) não recebeu reforço intra-radicular e foi obturado pela técnica da condensação lateral ativa; no grupo 04-(Controle negativo), os dentes não foram fragilizados. Os espécimes foram embutidos em blocos metálicos, os quais foram adaptados a um dispositivo cilíndrico, de modo que os espécimes foram fixados a 45°. Este dispositivo foi adaptado a um... / lmmature teeth when suffer trauma with consequent necrosis pulpar they stay with its dentinal walls thin and brittle, becoming more susceptible to the second injuries. The purpose of this work is to evaluate through the compression test, the resistance to fracture of teeth bovine brittleness that received reinforcements within the root canal with composite resin or pins of zircônia fiber. lt was used 56 bovine teeth, which had its crowns sectioned in the medium third standardizing the size of the specimens in 30mm of length. The teeth were divided in four experimental groups (14 teeth) and, except for the group 04 (negative control), all the root canal was instrumented to #80 and enlarged firstly with drills Gates-Glidden numbers 3, 4, 5 and 6 to 20mm of depth, after, lhe coronary portion was enlarged with the conical drill number 721 until the cementoenamel junction facial and, with lhe conical drill number 716, the brittleness of the dentinal walls of the root canal at 20mm of depth, leaving 2mm of thickness approximately in each wall. After, the specimens of the group 01 received reinforcement within the root canal with composite resin, that was cured by aid of the Luminex system and, after, they were obturated; in lhe group 02, the specimens were obturated. Just leaving the 10mm apical with material, and they received reinforcement within the root canal with zircônia fiber pins cemented with resinous cement; the group 03 (positive control) it didn't received reinforcement within the root canal and it was obturated by the technique of the active lateral condensation; in the group 04 (negative control), the teeth were not brittleness. After, all the specimens were embedded with acrylic resin chemically activated, in metallic blocks, which were adapted to a cylindrical device, so that the specimens were fractured by load in angle of 45°. This device was adapted to a lnstron machine, ...

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/114073
Date07 May 2002
CreatorsCarvalho, Cláudio Antonio Talge [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Valera, Marcia Carneiro [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format125 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0029 seconds