Return to search

Reologia e escoamento turbulento de suspensãões de minerio de ferra

Orientador: Cesar Costapinto Santana / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T07:07:16Z (GMT). No. of bitstreams: 1
Coelho_GersonLuizVieira_M.pdf: 2086820 bytes, checksum: 1905ecd606990ea367593047e519a54f (MD5)
Previous issue date: 1982 / Resumo: Foram realizados neste trabalho estudos experimentais no escoamento de suspensões de finos de minério de ferro (Hematita) a várias concentrações e temperaturas, nos regimes laminar e turbulento. Para a obtenção dos dados experimentais no regime laminar foi utilizado um reômetro capilar de tubos descartáveis sendo determinado o comportamento reológico das suspensões de minério de ferro na faixa de concentração de 25%, a 75%, em peso e nas temperaturas de 20, 30 e 40°C. Na interpretação dos resultados experimentais foram associadas às suspensões os modelos reológicos de fluidos de Bingham e de fluido do tipo "Power Law", visando a caracterização das suspensões para a previsão das perdas por atrito no escoamento laminar e turbulento. Os dados experimentais no escoamento turbulento foram obtidos em urna instalação piloto com tubos de 2,71cm e 5,22cm de diâmetros, para suspensões com concentrações de 40%, 50% e 65% em peso. A partir das várias correlações existentes na literatura o fator de atrito no escoamento turbulento foi calculado e comparado com valores experimentais visando analisar a validade e adequação das mesmas, objetivando o cálculo de potência de bombeamento. / Abstract: Experimental studies on the laminar and turbulent tube flow of iron ore suspensions were carried out. A special rheometer operating with disposable tubes was utilised in determining the rheological parameters of the suspensions. The concentrations, by weight, ranged from 25% to 75% and the temperatures used were 20, 30 and 40 °C. The behavior or the suspensions were fitted by the rheological models of Bingham and Power Law, for the calculation of friction losses for either laminar and turbulent tube flow. Experimental data in the turbulent tube flow were carried out in pilot plant with tubes of 2,71 and 5,22cm inner diameter and concentrations by weight of 40%, 50% and 65%. Friction factors in the turbulent region was calculated with experimental ones obtained in this work in order to check the correlations recomended and also to calculate pumping power in slurries pipelines. / Mestrado / Mestre em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/267046
Date02 February 1982
CreatorsCoelho, Gerson Luiz Vieira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Santana, Cesar Costapinto, 1948-
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format96f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.002 seconds