Return to search

Degradação de fenol por processos eletroquimico foto-assistido em escala piloto / Degradation of fenol using photo-assisted electrochemical process in pilot scale

Orientador: Edson Tomaz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-15T13:26:06Z (GMT). No. of bitstreams: 1
Baroni_Paula_M.pdf: 2153923 bytes, checksum: 0d73b228cc0146200966eb10e60b81f4 (MD5)
Previous issue date: 2010 / Resumo: A degradação de poluentes por biodegradação é um dos processos mais econômicos para o tratamento de compostos orgânicos. Na presença de substâncias tóxicas e recalcitrantes, entretanto, o processo biológico não é capaz de promover a degradação ou pode despender um tempo considerável para que a concentração requerida de um poluente seja alcançada. Os processos eletroquímicos foto-assistidos são uma alternativa ao tratamento de poluentes persistentes, possibilitando inclusive sua completa mineralização, devido à formação de radicais com alto poder de oxidação. O resultado positivo deste processo em diversos estudos levou à realização este trabalho, que tem como objetivo verificar a degradação de fenol em uma escala piloto. Foram utilizados quatro reatores tubulares em série, com área superficial interna de 0,18 m2 cada, revestidos com TiO2/RuO2 (70 %/30 %), que é o catalisador e anodo do sistema. No interior do reator apresenta-se o catodo, uma rede cilíndrica de titânio expandido a uma distância de 3 mm do anodo. Concentricamente ao catodo há um tubo de quartzo, dentro do qual a lâmpada ultravioleta permanece protegida. Os ensaios foram realizados em um volume de 80 L de uma solução de fenol de 100 mg.L-1 e 0,08 mol.L-1 de eletrólito suporte (K2SO4), avaliando-se a degradação de fenol, de carbono orgânico total e a formação dos intermediários de oxidação hidroquinona e benzoquinona, tendo como variáveis independentes no planejamento experimental a densidade de corrente, a vazão e o pH inicial. A densidade de corrente foi a variável mais significativa, sendo que a maior densidade utilizada (95 mA.cm-2) promoveu a melhor degradação, reduzindo 73 % da carga orgânica total e 99 % de fenol. Entretanto, a menor densidade de corrente garantiu maior eficiência energética ao processo. O ensaio com melhor desempenho (40 mA.cm-2; pH = 4,21; vazão = 3650 L.h-1) degradou 61 % de carbono orgânico total e 99 % de fenol, consumindo 2072 kWh por quilograma de carbono orgânico degradado e 1047 kWh por quilograma de fenol degradado, evidenciando a necessidade de otimização do processo. Alguns ensaios utilizando cloreto de sódio como eletrólito para a geração de cloro ativo no meio reacional não mostraram vantagens em relação ao uso de sulfato de potássio (K2SO4) / Abstract: The biodegradation of pollutants is one of the most economical types of treatment of organic wastewater. In the presence of toxic and recalcitrant compounds, however, the biological processes don't promote degradation or may spend considerable time to reach the required concentration of a pollutant. The photo-assisted electrochemical processes are an alternative treatment for recalcitrant pollutants, enabling their complete mineralization, due to the formation of radicals with high oxidation power. This process showed positive outcome for phenol degradation in several studies on laboratory scale, so this work aims to verify its efficiency in a pilot scale. It was used four tubular reactors in series, with inner surface area of 0.18 m2 each one, coated with an oxide layer composed of TiO2 / RuO2 (70% / 30%), which are the system's catalyst and also anode. Inside the reactor is the cathode, a cylindrical screen of expanded titanium, in a distance of 3 mm from the anode. Concentrically to the cathode is a quartz tube, within which the ultraviolet lamp remains protected. The experiments were carried out in 80 L of a 100 mg.L-1 phenol solution and 0.08 mol.L-1 of supporting electrolyte (K2SO4). In the experimental design, the dependent variables were the degradation of phenol, total organic carbon and the formation of the intermediates, hydroquinone and benzoquinone. The effects of current density, flow rate and initial pH on the degradation rate were investigated. The current density was the most significant variable and the highest density used (95 mA.cm-2) provided better degradation, reducing 73% of total organic carbon and 99% of phenol. However, the lower current density brought greater energy efficiency to the process. The best performance (40 mA.cm-2, pH = 4.21, F = 3650 L.h-1) degraded 61% of total organic carbon and 99% of phenol, consuming 2072 kWh per kilogram of organic carbon degraded and 1047 kWh per kilogram of phenol degraded, indicating the need for process optimization. Some tests using sodium chloride as electrolyte for the generation of active chlorine in the reaction, showed no advantages over the use of potassium sulphate (K2SO4) / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/267116
Date15 August 2018
CreatorsBaroni, Paula
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tomaz, Edson, 1963-, Rodrigues, Christiane de Arruda, Guimarães, José Roberto
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format98 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds