Return to search

Avaliação e aperfeiçoamento de uma bomba de sangue centrífuga implantável ápice ventricular para assistência cardíaca / Evaluation and improvement of an apico-aortic centrifugal blood pump for cardiac assist

Orientadores: Carlos Kenichi Suzuki, Aron José Pazin de Andrade / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-21T07:29:25Z (GMT). No. of bitstreams: 1
Silva_BrunoUtiyamada_M.pdf: 3089036 bytes, checksum: 01d1bb268591e2388a9bb34046fbd188 (MD5)
Previous issue date: 2012 / Resumo: Neste trabalho, foi realizado um estudo experimental de uma Bomba de Sangue Ápice Ventricular (BSAV) para sua análise como um dispositivo de assistência ventricular. Este estudo faz parte do desenvolvimento desta bomba e serviu como fundamentação na evolução do projeto. A BSAV é uma bomba de sangue centrífuga de fluxo contínuo, para ser utilizada como dispositivo de assistência ventricular em pacientes com doenças cardíacas crônicas. Foi realizado um estudo de posicionamento anatômico, onde a bomba foi implantada em um coração de um porco e não foram encontrados indícios de possíveis danos aos tecidos e órgãos circunvizinhos. Em seguida, foi feito um ensaio experimental, onde foi comparado o desempenho de protótipos com características distintas, visando sua otimização em relação ao desempenho hidrodinâmico. Também foi realizado um estudo para avaliação do trauma as células do sangue causado pela ação da bomba, no qual os resultados mostraram um baixo dano as células. A seguir, foi feito estudo com um protótipo conectado em um simulador cardiovascular híbrido (matemático e físico), onde este protótipo às condições simuladas de um sistema cardiovascular com insuficiência cardíaca. Com a BSAV conectada ao sistema obteve-se, uma melhora no fluxo de sangue, frequência cardíaca e pressão aórtica. Os resultados indicam que a BSAV é adequada para aplicação como dispositivo de assistência ventricular esquerda e é uma alternativa promissora no tratamento de pacientes com doenças cardíacas crônicas / Abstract: In this work an experimental study was realized with the Apico-Ventricular Blood Pump (AVBP) used as a ventricular assist device. This study is part of the device's development and the results were used for project evaluation and improvement. AVBP is a continuous flow centrifugal blood pump for ventricular assistance in chronic cardiac patients. Initially, an anatomic study was performed, in this study an AVBP prototype was implanted in a corpse of a pig, the clinical staff appointed, none damage to the nearby tissues and organs due to the contact with the device. Following step consists in an experimental hydrodynamic performance test. For this test the prototypes used had distinct specific construction characteristics variations among themselves, for device optimization, the performance of these different prototypes were compared, and the prototypes which presented a better performance had their characteristic adopted in the project. A study to determine the traumatic effect of the pump on blood cells was conducted, the results showed low damage to the blood cells. A hybrid mock loop circulation system (mathematical and physic) where the pump, was connected to a system with heart disease, was used. When the AVBP was inserted in the system, cardiac output, heart rate and aortic pressure went to normal values. All results indicated the performance of the AVBP as ventricular assist device, an alternative for treatment of patients with cardiac chronic diseases / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/264976
Date21 August 2018
CreatorsSilva, Bruno Utiyama da
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Andrade, Aron José Pazin de, Suzuki, Carlos Kenichi, 1945-, Arruda, Antonio Celso Fonseca de, Legendre, Daniel Formariz
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format91 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0027 seconds