An elevator group control system manages multiple elevators to serve hall
calls in a building. Most elevator group control systems need to recognize the traffic
pattern of the building and then change their control algorithms to improve the
efficiency of the elevator system. However, the traffic flow in a building is very
difficult to be classified into distinct patterns. Traffic recognition systems can
recognize certain traffic patterns, but mixed traffic patterns are difficult to be
recognized.
The aim of this study was therefore to develop improved duplex elevator
group control systems that do not need to recognize the traffic pattern. A fuzzy logic.
control unit and genetic algorithms control unit were used. A fuzzy logic control unit
integrates with the conventional duplex elevator group control system to improve
performance especially in mixed traffic patterns with intermittent heavy traffic
demand. This system will send more than one elevator to a floor with heavy demand, . according to the overall passenger traffic conditions in the building.
The genetic algorithms control unit divides the building into three zones and assigns an appropriate number of elevators to each zone. The floors covered by each zone are adjusted every five minutes. This control unit optimizes elevator group control by equalizing the number of hall calls in each zone, the total elevator door opening time in each zone, and the number of floors served by each elevator.
Both of the control units were tested by a simulator in a computer. The performance of the elevator system is given by indices such as average waiting time, wasted man-hour, and long waiting time percentage. The new performance index "wasted man-hour" indicates the total time spent by passengers in a building waiting for the lift service. Both proposed systems perform better than the conventional duplex control system.
(An abstract of 297 words.)
~
Signed _
Wong King Sau / abstract / toc / Mechanical Engineering / Doctoral / Doctor of Philosophy
Identifer | oai:union.ndltd.org:HKU/oai:hub.hku.hk:10722/31202 |
Date | January 2003 |
Creators | Wong, King-sau, 黃敬修 |
Contributors | Cheung, KC |
Publisher | The University of Hong Kong (Pokfulam, Hong Kong) |
Source Sets | Hong Kong University Theses |
Language | English |
Detected Language | English |
Type | PG_Thesis |
Source | http://hub.hku.hk/bib/B2768295X |
Rights | The author retains all proprietary rights, (such as patent rights) and the right to use in future works. |
Relation | HKU Theses Online (HKUTO) |
Page generated in 0.0023 seconds