Return to search

Caracterização microbiológica, parasitológica e físico-química da água de lavagem de filtros recirculada em ETA de ciclo completo = Microbiological, parasitological and physico-chemical characterization of filter backwash water recirculated in full cycle WTP / Microbiological, parasitological and physico-chemical characterization of filter backwash water recirculated in full cycle WTP

Orientador: Cassiana Maria Reganhan-Coneglian / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Tecnologia / Made available in DSpace on 2018-08-26T04:53:56Z (GMT). No. of bitstreams: 1
Canale_Ivan_M.pdf: 7288933 bytes, checksum: 93678fbce9055e79b05000fd1cab8c23 (MD5)
Previous issue date: 2014 / Resumo: Estações de Tratamento de Água (ETA) de ciclo completo. Como o volume de ALF pode representar de 3 a 6% do volume de água tratada produzido na ETA, existe interesse cada vez maior no tratamento desse efluente para fins de recirculação junto com a água bruta aduzida à ETA. Entretanto, existe uma preocupação de que essa água residuária possa conter matéria orgânica, sólidos totais, metais, carbono orgânico, precursores de trihalometanos, cistos/oocistos de protozoários ou outras impurezas concentradas durante o processo de filtração. Este trabalho de pesquisa tem como objetivo caracterizar com base em parâmetros físico-químicos, microbiológicos e parasitológicos a água de lavagem de filtros gerada e recirculada na ETA Capim Fino, em Piracicaba / SP - Brasil. Foram avaliadas 12 amostras da água bruta do manancial que abastece a ETA (rio Corumbataí), ALF bruta, ALF clarificada (com o uso de polímeros auxiliares ou por simples sedimentação) e água filtrada da ETA. Para caracterização da ALF foram analisados os parâmetros físico-químicos: cloro residual, cor, turbidez, pH, alumínio solúvel, sólidos totais fixos, sólidos totais voláteis, sólidos sedimentáveis, carbono orgânico total e o potencial de formação de trihalometanos; os parâmetros microbiológicos: coliformes totais, Escherichia coli; e os protozoários patogênicos: Giardia spp. e Cryptosporidium spp. O monitoramento da ALF bruta apontou como principais características físico-químicas deste efluente elevados teores de turbidez, alumínio, carbono orgânico total, sólidos totais (fixos e voláteis), sólidos sedimentáveis e potencial de formação de THM. A clarificação da ALF com polímero aniônico possibilitou a redução na concentração dos diversos constituintes analisados. Giardia spp. foi detectada na água bruta (cinco resultados positivos e concentração de cistos variando de <LMD a 75,0 cistos/litro) e na ALF clarificada (dois resultados positivos e concentração de 50 cistos/litro). A pré-cloração realizada na ETA, bem como o uso de água tratada (clorada) para lavagem dos filtros garantiu praticamente ausência de E. coli na água de lavagem. A avaliação da água filtrada da ETA apresentou resultados em conformidade com a Portaria 2914/2011 (padrão de potabilidade) do Ministério da Saúde, com exceção da turbidez, onde foram observados quatro resultados acima do limite de 0,5 NTU estabelecido pela Portaria (1,53, 0,54 , 0,59 e 0,74 NTU), o que pode indicar um transpasse de partículas no efluente filtrado nos primeiros minutos seguintes à lavagem dos filtros. Não foram detectados E. coli ou protozoários na água filtrada. Diante do fato que a recirculação da ALF clarificada junto com a água bruta está ocorrendo numa vazão de 60 L/s, que corresponde a 4,5% da vazão de água bruta (1300 L/s) e de forma intermitente, provavelmente não deverão ocorrer efeitos indesejáveis ao processo de tratamento ou o comprometimento da qualidade da água tratada. Com intuito de precaução, é importante que seja dada toda a atenção ao tratamento (clarificação) da ALF antes da recirculação, para redução da turbidez a níveis mínimos possíveis e que a recirculação do efluente clarificado seja realizada na vazão de 4,5% ou menor / Abstract: Filter backwash water (FBWW) is the largest liquid waste generated in a conventional water treatment plant (WTP). As the volume of FBWW can represent from 3 to 6% of the volume of treated water produced in the WTP, there is an increasing interest in treatment and recycling of this effluent with raw water adducted to WTP. But FBWW would contain concentrated organic matter, total solids, metals, organic carbon, trihalomethanes (THM) precursors, cysts/oocysts of protozoa and other impurities which could be a concern. This research aims to characterize FBWW generated and recirculated in Capim Fino WTP in Piracicaba / SP - Brazil by physico-chemical, microbiological and parasitological analyses. Twelve samples of raw water from the river that supplies the WTP (Corumbataí river), raw FBWW, clarified FBWW (using auxiliary polymers or simple sedimentation) and filtered water were collected and evaluated. The physico-chemical parameters were: residual chlorine, color, turbidity, pH, soluble aluminum, total fixed and volatile solids, settleable solids, total organic carbon and THM potential formation; microbiological parameters: total coliforms and Escherichia coli; and pathogenic protozoa Giardia spp. and Cryptosporidium spp. Monitoring the raw FBWW pointed as the main physicochemical characteristics high levels of turbidity, aluminum, total organic carbon, total solids (fixed and volatile), sedimentary solids and THM potential formation. Clarification of FBWW with anionic polymer resulted in a reduction in the concentration of the various parameters. Giardia spp. was found in raw water (five positive results and cyst concentration ranging from <Minimum Detection Limit to 75 cysts/liter) and in clarified FBWW (two positive results, concentration of 50 cysts/liter). The pre-chlorination performed in the WTP and the use of treated water (chlorinated) for washing the filters virtually assured absence of E. coli in the FBWW. The filtered water were in compliance with the Brazilian drinking water standards, with the exception of turbidity. Four samples were above the maximum limit of 0.5 NTU (1.53, 0.54, 0.59 and 0.74 NTU), which may indicate a passage of particles in the first minutes after the washing of the filters. E. coli and protozoa were not detected in the filtered water. Because of the recirculation of clarified FBWW is mixed with raw water at a flow of 60 L/s, which corresponds to 4.5% of the flow of raw water (1300 L/s) and intermittently, it is probable that no undesirable effects would occur in the treatment and in the quality of the drinking water. It is important that full attention is given to treatment (clarification) of FBWW before recirculation to reduce turbidity to the minimum levels that are possible and that the recirculation of clarified effluent is conducted at a flow rate of 4.5% or less / Mestrado / Tecnologia e Inovação / Mestre em Tecnologia

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/267710
Date11 April 2014
CreatorsCanale, Ivan, 1977-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Reganhan-Coneglian, Cassiana Maria, 1970-, Monteiro, Regina Teresa Rosin, Nour, Edson Aparecido Abdul
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Tecnologia, Programa de Pós-Graduação em Tecnologia
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format125 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds