The purpose of this study is to determine if element decimation of a 3-D anatomical model affects the results of Finite Element Analysis (FEA). FEA has been increasingly applied to the biological and medical sciences. In order for an anatomical model to successfully run in FEA, the 3-D model’s complex geometry must be simplified, resulting in a loss of anatomical detail. The process of decimation reduces the number of elements within the structure and creates a simpler approximation of the model. Using the National Library of Medicine’s Visible Human Male dataset, a virtual 3-D representation of several structures of the hip were produced. The initial highest resolution model was processed through several levels of decimation. Each of these representative anatomical models were run in COMSOL 3.5a to measure the degree of displacement. These results were compared against the original model to determine what level of error was introduced due to model simplification.
Identifer | oai:union.ndltd.org:USF/oai:scholarcommons.usf.edu:etd-4646 |
Date | 04 October 2010 |
Creators | Ford, Jonathan M. |
Publisher | Scholar Commons |
Source Sets | University of South Flordia |
Detected Language | English |
Type | text |
Format | application/pdf |
Source | Graduate Theses and Dissertations |
Rights | default |
Page generated in 0.0019 seconds