This thesis is focused on the theoretical and practical introduction to the verification procedures used today for obtaining luminosity curves of lamps. The introduction acquaints readers with the photometric variables. Consequently, it is theoretically described procedure for constructing luminance curves by zonal flow and further familiarization with the near-field photometry. For the practical part was chosen several lights. These lamps were measured by luxmeter first from a very close photometric distance from lights, and then from large distance. The next step was to obtain pictures of luminaries in planes C 0 to 345 ° (with a step of 15 °) of the angle gamma from 0 to 180 ° (in steps of 5 °). The measured data were processed by zonal flow and through programs LumiDISP and Matlab. The partial result of this thesis is to verify whether it is possible to use the luminance analyzer for obtaining luminosity curves, it means, if the luminosity curve obtained through luminance analyzer will comply with the curves obtained through a luxmeter. Further work should ascertain the feasibility of acquired photographs lamps from a very close photometric distance could create luminosity curve for any location and distance from the observer to measured lamps.