Measurements performed from stereo reconstruction can be obtained with a high accuracy with correct calibrated cameras. A stereo camera rig mounted in an outdoor environment is exposed to temperature changes, which has an impact of the calibration of the cameras. The aim of the master thesis was to investigate the thermal impact of a calibrated stereo camera rig. This was performed by placing a stereo rig in a temperature chamber and collect data of a calibration board at different temperatures. Data was collected with two different cameras and lensesand used for calibration of the stereo camera rig for different scenarios. The obtained parameters were plotted and analyzed. The result from the master thesis gives that the thermal variation has an impact of the accuracy of the calibrated stereo camera rig. A calibration obtained in one temperature can not be used for a different temperature without a degradation of the accuracy. The plotted parameters from the calibration had a high noise level due to problems with the calibration methods, and no visible trend from temperature changes could be seen.