Return to search

Inversores multiníveis híbridos assimétricos com acoplamento magnético

Submitted by Emanuel Varela Cardoso (emanuel.varela@ufcg.edu.br) on 2018-08-28T20:15:07Z
No. of bitstreams: 1
DIEGO ALBERTO ACEVEDO BUENO – DISSERTAÇÃO (PPGEEI) 2015.pdf: 8647076 bytes, checksum: c16b323a227c1c3224d8f023324db513 (MD5) / Made available in DSpace on 2018-08-28T20:15:07Z (GMT). No. of bitstreams: 1
DIEGO ALBERTO ACEVEDO BUENO – DISSERTAÇÃO (PPGEEI) 2015.pdf: 8647076 bytes, checksum: c16b323a227c1c3224d8f023324db513 (MD5)
Previous issue date: 2015-08 / CNPq / Esta dissertação examina seis topologias hibridas assimétricas com acoplamento
magnético. O termo topologia hibrida assimétrica se refere a qualquer topologia que combine os princípios das topologias clássicas com duas fontes de tensão isoladas ou mais com tensões diferentes. Das topologias propostas, quatro possuem saída única conectada ao ponto intermediário do barramento e as restantes dispõem de saída diferencial usando outro braço de dois níveis. Para simplificar o estudo destas topologias, desenvolveu-se um modelo elétrico e magnético detalhado dos indutores acoplados usando componentes de modo comum e diferencial. Posteriormente, esse modelo foi inserido no modelo do conversor para o desenvolvimento de uma estratégia de controle da corrente de saída e da corrente de modo diferencial garantindo a operação em modo de condução continua com número reduzido de componentes. Os modos de operação e as respectivas estratégias de modulação são apresentados. Além disso, o efeito da diferença das tensões de polo máximas sobre o desempenho dos conversores e na escolha do indutor acoplado foi analisado. Para avaliar o desempenho destas topologias, foram realizadas simulações com os modelos completos das chaves e dos diodos usando o software PSIM fixando a potência de saída para todas as topologias em 1 kVA. Também, alguns resultados experimentais em malha aberta são apresentados para validar os modelos desenvolvidos / This paper examines six asymmetric hybrid topologies with magnetic coupling. The term
“asymmetric hybrid topology” refers to any topology that combines the principles of classical topologies with two isolated voltage sources or more with different voltages. From these topologies, four have single-ended output connected to the midpoint of dc-link and the remaining has differential output employing another two-level arm. To simplify the analysis, a detailed electric and magnetic model of the coupled inductors was developed appealing to common- and differential-mode components. Subsequently, this model was inserted into the model of the converter for developing a control strategy for the output and the differential mode currents, ensuring the operation in continuous conduction mode with a reduced number of components. The modes of operation and the modulation strategies are presented. In addition, the difference of the maximum pole voltages was analyzed for determining its effect on the converter performance and the coupled inductor selection. To evaluate the performance of these topologies, simulations were performed with the complete models of switches and diodes using the PSIM software by setting the output power at 1 kVA for all topologies. Also, experimental open loop results are presented to validate the developed models.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:riufcg/1573
Date28 August 2018
CreatorsBUENO, Diego Alberto Acevedo.
ContributorsSILVA, Edison Roberto Cabral da., JACOBINA, Cursino Brandão., VITORINO, Montiê Alves.
PublisherUniversidade Federal de Campina Grande, PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA, UFCG, Brasil, Centro de Engenharia Elétrica e Informática - CEEI
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca de Teses e Dissertações da UFCG, instname:Universidade Federal de Campina Grande, instacron:UFCG
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds