Orientador: Marcos Nogueira Eberlin / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-15T19:01:40Z (GMT). No. of bitstreams: 1
Lalli_PriscilaMicaroni_M.pdf: 4223184 bytes, checksum: 852704419d68edf5bd13623379abf7b4 (MD5)
Previous issue date: 2010 / Resumo: Na espectrometria de mobilidade iônica, íons de diferentes tamanhos ou conformações espaciais em fase gasosa são separados de acordo com o tempo que levam para atravessar um gás sob a influência de um campo elétrico. O acoplamento dessa técnica à espectrometria de massas (IMMS) resulta numa ferramenta extremamente versátil, capaz de investigar a estrutura molecular e separar amostras complexas, incluindo isômeros. No capítulo I, diferentes gases foram utilizados na separação dos isômeros N-butil anilina e p-butil anilina a fim de investigar a interação íon/molécula durante o processo de mobilidade iônica. Mostramos que as moléculas do drift gas não atuam apenas como barreiras físicas que atrasam os íons, como geralmente são consideradas, mas podem interagir quimicamente com os íons. No caso desses isômeros, gases mais polarizáveis como eteno e CO2 mostraram melhorar consideravelmente a separação. Acredita-se que a grande diferença de polarizabilidade entre os isômeros esteja relacionada com este fato, pois o gás mais polarizável interagiria melhor com o isômero também mais polarizável atrasando-o numa intensidade maior. Gases mais massivos e pressões maiores também ajudam a melhorar consideravelmente a separação de isômeros. No capítulo II, a IMMS foi usada para determinar pela primeira vez a mobilidade intrínseca de uma série de agregados catiônicos e aniônicos de líquidos iônicos na fase gasosa. Os resultados são condizentes com as medidas feitas em solução por RMN, que mostram uma aparente anomalia em que os cátions, mais volumosos, viajam mais rápido do que os ânions. Esse comportamento ainda não é muito bem compreendido, entretanto, pode estar relacionado à orientação dos íons pelo campo ou a diferença de dureza entre cátions e ânions / Abstract: Ion mobility spectrometry separates ions with different sizes or spacial conformations in gas phase according to the time they take to travel through a gas under the influence of an electrical field. Coupling this technique to mass spectrometry provides an extremely versatile tool, able to investigate molecular structure and separate complex samples, including isomers. In Chapter I, different gases were used to separate the isomers N-butyl aniline and p-butil aniline in order to investigate the ion/molecule interaction during the ion mobility process. We have shown that drift gas molecules don¿t act only as physical barriers that slow down the ions, as they are usually considered, but they may interact chemically with them. In the case of these isomers, more polarizable gases such as ethene and CO2 have shown to improve considerably the isomer separation. We believe that the large difference of polarizability between both isomers is related to this fact, because more polarizable gases would interact better with the more polarizable isomer slowing it down more intensively. More massive gases and higher pressures also help improve isomer separation. In Chapter II, IMMS was used to perform the first measurements of the intrinsic mobility of a series of gaseous cationic and anionic aggregates of ionic liquids. Results confirm previous mobility measurements by NMR, which show an apparent anomaly in which the bulkier cations travel faster than respective anions. This behavior isn¿t well understood yet, however, it may be related to the ions orientation by the field or to the hardness difference between cations and anions / Mestrado / Quimica Analitica / Mestre em Química
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/248681 |
Date | 15 August 2018 |
Creators | Lalli, Priscila Micaroni |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Eberlin, Marcos Nogueira, 1959-, Moraes, Luiz Alberto Beraldo de, Gozzo, Fábio Cesar |
Publisher | [s.n.], Universidade Estadual de Campinas. Instituto de Química, Programa de Pós-Graduação em Química |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 45 f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0038 seconds