Return to search

Estudo comparativo entre oito sistemas de lagoas de estabilização da região noroeste do Estado de São Paulo / Comparative study of eight systems of stabilization ponds in the northwestern region of São Paulo

Este trabalho comparou oito lagoas de estabilização da região Noroeste do Estado de São Paulo, que tratam esgotos predominantemente sanitários de Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Irapuã e Adolfo, cidades pequenas, com no máximo 5500 habitantes (1700 ligações), onde os quatro primeiros sistemas são compostos apenas por lagoas facultativas primárias e os quatro últimos por lagoas anaeróbias e lagoas facultativas secundárias. Vinte e cinco variáveis físicas, químicas e biológicas foram analisadas em amostras compostas coletadas entre 24/05/2000 e 03/10/2000. A análise da batimetria efetuada fornece indicações de prazos para a remoção do lodo do fundo das lagoas. As taxas de acúmulo de lodo médias obtidas para as lagoas anaeróbias e facultativas primárias foram de 0,07 e 0,14 m3/hab.ano, respectivamente. O pH do efluente das lagoas anaeróbias e das facultativas foi em média 6,6 e 7,4. Nas lagoas anaeróbias observou-se alta remoção de sólidos suspensos e de Demanda Bioquímica de Oxigênio (DBO) com eficiência geral média de 64% e 61% respectivamente. Os sistemas não atenderam plenamente à legislação no tocante a eficiência de remoção de DBO de 80%, porém o valor médio encontrado para os oito sistemas foi de 78%, bastante próximo do exigido. Sugere-se para a região, para eficiência de remoção de DBO de 80%, lagoas anaeróbias com tempo de detenção de 5 dias e para as lagoas facultativas primárias e secundárias tempos de detenção de 25 e 15 dias respectivamente, e taxas de aplicação superficial de 140 e 130 kg DBO/ha.dia, respectivamente. Não foi atingido o limite máximo de 1000 coliformes fecais por 100 ml, obtendo-se média geral de remoção de 97,40% inferindo-se que há necessidade de um processo de tratamento complementar para a remoção de microrganismos. Não observou-se correlação entre eficiência do sistema e relação comprimento/largura das lagoas. Constatou-se maus odores mesmo na ausência de concentrações detectáveis de sulfeto. A remoção média geral de amônio (NH4+), nitrogênio total, fosfato total dissolvido e fósforo total foi de 31%, 12%, 24% e 27% respectivamente nos sistemas estudados. / The present work compared the performance of eight stabilization ponds in the Northwest region of São Paulo state, that treat predominantly the domestic sewage from eight small cities with a maximum of 5000 inhabitants (1700 links): Coroados, Lourdes, Planalto, Zacarias, Alto Alegre, Pongaí, Trapuã and Adolfo. The first four systems are made of four primary facultative ponds and the last four by anaerobic ponds and secondary facultative ponds. A total of twenty-five chemical, physical and biological variables were analyzed in integrated samples collected between 24/05/2000 and 03/10/2000. The bathymetric analysis performed has indicated deadlines for sludge removal from the stabilization pond bottom. Mean sludge accumulation rates o btained for anaerobic and primary facultative ponds were 0.07 and 0.14 m3/inhabt.year, respectively. Effluents from anaerobic and facultative ponds had a mean pH of 6.6 and 7.4. In anaerobic ponds a righ rate of suspended solids removal was found and the Biochemical Oxygen Demand (BOD) had an overall general efficiency of 64% and 61%, respectively. The systems did not completely attend the present legislation in respect to a BOD removal of 80%, as required, however the mean value for the eight systems monitored was 78%, very close to the established limit. It is therefore suggested that for this region, in order to attain the removal efficiency of 80% anaerobic ponds should have a residence time of 5 days and the primary and secondary facultative ones should have residence times of 25 and 15 days respectively, coupled to loading rates of 140 and 170 Kg BOD/ha.day respectively. Also, the maximum limit of 1000 fecal coliforms per 100 ml was not reached, and in general there was a mean removal efficiency of 97.40%, indicating that an additional treatment process needs to be implemented for a successful removal of coliforms. No correlation was found between the removal efficiency and morphometry (length/weight) pond characteristics. Bad smell was present even in the absence of detectable amounts of sulfide. The mean efficiency for the removal of ammonium (NH4+), total nitrogen, total dissolved phosphorus and total phosphorus were 31%, 12%, 24%, and 27% respectively, among the systems studied.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-05012016-165315
Date10 April 2002
CreatorsJoão Luiz Cais da Silva Gomes
ContributorsOdete Rocha, Luiz Antonio Daniel, Roque Passos Piveli
PublisherUniversidade de São Paulo, Engenharia (Hidráulica e Saneamento), USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds