Irreversible electroporation has recently emerged as an effective focal ablation technique. When performed clinically, the procedure involves placing electrodes into, or around, a target tissue and applying a series of short, but intense, pulsed electric fields. Oftentimes, patient specific treatment plans are employed to guide procedures by merging medical imaging with algorithms for determining the electric field distribution in the tissue. The electric field dictates treatment outcomes by increasing a cell's transmembrane potential to levels where it becomes energetically favorable for the membrane to shift to a state of enhanced permeability. If the membrane remains permeabilized long enough to disrupt homeostasis, cells eventually die. By utilizing this phenomenon, irreversible electroporation has had success in killing cancer cells and treating localized tumors. Additionally, if the pulse parameters are chosen to limit Joule heating, irreversible electroporation can be performed safely on surgically inoperable tumors located next to major blood vessels and nerves.
As with all technologies, there is room for improvement. One drawback associated with therapeutic irreversible electroporation is that patients must be temporarily paralyzed and maintained under general anesthesia to prevent intense muscle contractions occurring in response to pulsing. The muscle contractions may be painful and can dislodge the electrodes. To overcome this limitation, we have developed a system capable of achieving non-thermal irreversible electroporation without causing muscle contractions. This progress is the main focus of this dissertation. We describe the theoretical basis for how this new system utilizes alterations in pulse polarity and duration to induce electroporation with little associated excitation of muscle and nerves. Additionally, the system is shown to have the theoretical potential to improve lesion predictability, especially in regions containing multiple tissue types. We perform experiments on three-dimensional in vitro tumor constructs and in vivo on healthy rat brain tissue and implanted tumors in mice. The tumor constructs offer a new way to rapidly characterize the cellular response and optimize pulse parameters, and the tests conducted on live tissue confirm the ability of this new ablation system to be used without general anesthesia and a neuromuscular blockade.
Situations can arise in which it is challenging to design an electroporation protocol that simultaneously covers the targeted tissue with a sufficient electric field and avoids unwanted thermal effects. For instance, thermal damage can occur unintentionally if the applied voltage or number of pulses are raised to ablate a large volume in a single treatment. Additionally, the new system for inducing ablation without muscle contractions actually requires an elevated electric field. To ensure that these procedures can continue to be performed safely next to major blood vessels and nerves, we have developed new electrode devices that absorb heat out of the tissue during treatment. These devices incorporate phase change materials that, in the past, have been reserved for industrial applications. We describe an experimentally validated numerical model of tissue electroporation with phase change electrodes that illustrates their ability to reduce the probability for thermal damage. Additionally, a parametric study is conducted on various electrode properties to narrow in on the ideal design. / Ph. D.
Identifer | oai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/50605 |
Date | 03 May 2013 |
Creators | Arena, Christopher Brian |
Contributors | Biomedical Engineering, Davalos, Rafael V., Rossmeisl, John H. Jr., Robertson, John L., Garcia, Paulo Andres, Rylander, M. Nichole |
Publisher | Virginia Tech |
Source Sets | Virginia Tech Theses and Dissertation |
Detected Language | English |
Type | Dissertation |
Format | ETD, application/pdf, application/pdf, application/pdf, application/pdf, application/pdf |
Rights | In Copyright, http://rightsstatements.org/vocab/InC/1.0/ |
Page generated in 0.0033 seconds