Return to search

Estudo de parâmetros eletrocardiográficos e de pressão arterial durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em portadores de doença arterial coronária / Investigation of electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia with and without vasoconstrictor in coronary artery disease patients

Estudamos 62 pacientes, que com teste ergométrico positivo, manifestaram angina estável e estavam sob controle farmacológico. Todos apresentavam cinecoronariografia mostrando obstrução >70% em pelo menos uma das principais artérias coronárias. Objetivamos avaliar parâmetros eletrocardiográficos e de pressão arterial, durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em presença de doença arterial coronária. As idades variaram de 39 a 80, média de 58,7±8,8 anos, sendo 51 (82,3%) homens. Trinta pacientes foram randomizados para receber anestesia local com solução de lidocaína a 2% com adrenalina 1:100.000 e os demais para lidocaína a 2% sem vasoconstritor. Todos os pacientes foram submetidos à monitorização ambulatorial da pressão arterial (MAPA) e eletrocardiografia dinâmica por 24 horas, iniciados 2 horas antes do procedimento odontológico. Consideramos 3 períodos de registro: (1) basal - os 60 minutos que antecederam ao procedimento odontológico; (2) procedimento - desde o início da anestesia até o final do procedimento odontológico restaurador; (3) subseqüente completar das 24 horas. A análise de variância com medidas repetidas mostrou que houve elevação significativa da pressão arterial sistólica e diastólica do período basal para o procedimento nos dois grupos estudados (aproximadamente 14mmHg e 5 a 7mmHg) respectivamente, quando analisados separadamente e quando confrontados não apresentaram diferença de comportamento entre si. A freqüência cardíaca não se alterou nos dois grupos estudados. Depressão do segmento ST >1mm ocorreu em 10 (17,9%) pacientes; todos os eventos ocorreram no mínimo 2 horas após o término do procedimento odontológico. Extra - sístoles supra-ventriculares e/ou extra-sístoles ventriculares em número maior do que 10/hora estiveram presentes em 17 (30,4%) pacientes durante as 24 horas e durante o período do procedimento em 7 (12,5%), sendo 4 (13,8%) do grupo que recebeu anestesia sem adrenalina e 3 (11,1%) do grupo que recebeu anestesia com adrenalina e o teste Exato de Fisher não mostrou diferença entre os grupos. Concluímos que não houve diferença em relação ao comportamento de pressão arterial, freqüência cardíaca, evidência de isquemia e arritmias entre os grupos. O uso associado de vasoconstritor mostrou-se, portanto, seguro dentro dos limites do estudo. / We enrolled 62 patients with positive exercise stress test who presented with stable angina and were receiving drug therapy. All had a coronary angiography screening showing >70% obstruction in at least one of the main coronary arteries. The study aimed to compare electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia, both with and without vasoconstrictor, in the presence of coronary artery disease. Ages ranged from 39 to 80, (mean ± SD) 58.7±8.8 years, 51 (82.3%) of them were male. Thirty patients were randomly assigned to receive 2% lidocaine local anesthesia with 1:100,000 epinephrine, the others receiving 2% lidocaine without vasoconstrictor. All the patients underwent ambulatory blood pressure and 24-hour Holter monitoring, beginning two hours ahead of the dental procedure. Recording were made during (1) baseline - 60-minute period before dental procedure began; (2) procedure - from beginning of anesthesia until the end of the procedure; and (3) subsequent 24-hour period. Analysis of variance with repeat measures showed significant diastolic and systolic blood pressure increases from baseline to the period of the procedure, in the two study groups (approximately 14 mm Hg, and 5 to 7 mm Hg, respectively); both in a separate analysis and in a comparative analysis no significant difference between them could be confirmed. Heart rate did not change in neither of the two groups. ST-segment >1 mm depression was detected in 10 (17.9%) patients; all these events occurred at least two hours after the end of the dentistry procedure. Premature supraventricular systoles and/or premature ventricular systoles in a greater number than 10/hour were seen in 17 (30.4%) patients in the 24-hours period after the procedure; during the procedure they occurred in 7 (12.5%) patients, of whom 4 (13.8%) were in the group without, and 3 (11.1%) in the group with vasoconstrictor. The Fisher\'s exact test revealed no difference between the groups. We concluded that there was no difference of blood pressure, heart rate, evidence of ischemia or arrhythmia episodes between the groups. Thus, the associated use of vasoconstrictor proved to be safe within the limits of this study

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-06022007-142629
Date12 December 2006
CreatorsRicardo Simões Neves
ContributorsMax Grinberg, Roberto Alexandre Franken, Paulo Jorge Moffa, Jose Luiz Santello, Moacyr da Silva
PublisherUniversidade de São Paulo, Cardiologia, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds