Return to search

Avaliação do desempenho lumínico de ambientes residenciais

Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2018-05-11T12:16:00Z
No. of bitstreams: 1
Cristina Biazus Danieleski_.pdf: 107855847 bytes, checksum: 3e52ad5d285bbd1e32564a7637140fe3 (MD5) / Made available in DSpace on 2018-05-11T12:16:00Z (GMT). No. of bitstreams: 1
Cristina Biazus Danieleski_.pdf: 107855847 bytes, checksum: 3e52ad5d285bbd1e32564a7637140fe3 (MD5)
Previous issue date: 2018-02-23 / Nenhuma / A utilização da luz natural pode contribuir com a redução do uso de iluminação artificial em ambientes internos e, consequentemente, diminuir a carga elétrica de edificações. Esta pesquisa teve como objetivo avaliar o desempenho lumínico de ambientes de cozinha e de área de serviço de residências multifamiliares com diferentes configurações espaciais na cidade de Porto Alegre – RS, por meio dos critérios da NBR 15575 e do método Useful Daylight Illuminance (UDI). Os objetos de estudo abrangeram os ambientes de cozinha e de área de serviço divididos em dois grupos: três modelos com iluminação natural de maneira direta e quatro modelos em que a cozinha foi iluminada de maneira indireta. Além disso, investigou-se a influência de elementos externos inerentes à edificação, como laje técnica e brise de proteção solar. As análises foram realizadas por meio de simulação computacional com o software DIALux e o plug-in Diva para Rhinoceros em quatro orientações solares: norte, sul, leste e oeste. A fim de alcançar resultados precisos, as refletâncias das superfícies internas foram obtidas por análise espectroradiométrica, que apontou maior capacidade de refletância dos revestimentos com cor branca. Com base nas análises realizadas pela NBR 15575, classificou-se como desempenho lumínico intermediário apenas a cozinha do modelo que possuía brise de proteção solar, à medida que todos os outros ambientes foram classificados como desempenho superior. Os resultados obtidos pelo método UDI indicaram a prevalência do intervalo autônomo nos modelos com iluminação de maneira direta e o intervalo suplementar nos objetos de estudo com luz natural obtida de maneira indireta. Com base nos modelos analisados nas duas etapas de simulação computacional, afirma-se que os ambientes que possuíam elemento externo obtiveram menores valores de iluminância. Em relação aos métodos de classificação da luz natural em ambientes internos, a iluminância no ponto do centro geométrico indicada pela normativa não coincidiu com a bancada da pia da cozinha, assim, não se teve a garantia do mesmo nível de desempenho lumínico nessa superfície, enquanto que o método UDI considera a iluminância média do recinto, abrangendo áreas com menor incidência de luz natural. / The use of natural light in indoor environments can contribute to reduce the artificial lighting and, as a result, to reduce the electrical load of buildings. The objective of this research was to evaluate the lighting performance in kitchen and service area environments of multifamily residential with different spatial configurations in the city of Porto Alegre - RS, using NBR 15575 Norm criteria and the Useful Daylight Illuminance (UDI) method. The study objects covered the kitchen and the service area into two groups: three models with direct natural lighting and four models in which the kitchen was illuminated indirectly. In addition, the research investigated the influence of external elements inherent to the building, such as technical slab and solar protection brise. The analyses were carried out through computer simulation with DIALux software and the Diva plug-in in Rhinoceros in four solar orientations: north, south, east and west. In order to achieve the most accurate results, the internal surface reflectances were obtained by spectroradiometric analysis, which indicated a higher reflectability of the white coatings. Based on the analyses carried out by NBR 15575 Norm, only the kitchen of the model that possessed sun protection brise was classified as intermediate lighting performance, as all other environments were classified as superior performance. The results obtained through the UDI method indicated the prevalence of the autonomous range in the models with direct lighting and the supplementary range in the study objects with natural light obtained indirectly. Based on the models analysed in the two stages of computational simulation, it is possible to state that the environments that had external elements obtained lower values of illuminance. Regarding methods of classification of natural light in indoor environments, the illuminance of the central point indicated by the normative did not coincide with the kitchen sink bench, therefore, the same level of light performance on this surface was not guaranteed, as the UDI method considers the average illuminance of the enclosure, covering areas with lower incidence of natural light.

Identiferoai:union.ndltd.org:IBICT/oai:www.repositorio.jesuita.org.br:UNISINOS/7052
Date23 February 2018
CreatorsDanieleski, Cristina Biazus
Contributorshttp://lattes.cnpq.br/1555729873996754, Oliveira, Maria Fernanda de
PublisherUniversidade do Vale do Rio dos Sinos, Programa de Pós-Graduação em Arquitetura e Urbanismo, Unisinos, Brasil, Escola Politécnica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNISINOS, instname:Universidade do Vale do Rio dos Sinos, instacron:UNISINOS
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds