Return to search

Estudo da corrosão de aços de elevado limite elástico e das suas uniões com metais duros ou cermet e com aço/WC-Co em 'NA''CL' 0,6 mol 'L POT. -1'

Made available in DSpace on 2014-06-11T19:25:34Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-01-21Bitstream added on 2014-06-13T19:32:50Z : No. of bitstreams: 1
akita_ah_me_araiq.pdf: 2521064 bytes, checksum: d6299e2b6a5a5f33b4d14c1d8463e878 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dois sistemas foram estudados utilizando uma microcélula desenvolvida no laboratório: a) ferricianeto/ferrocianeto em KCl 0,6 mol L-1 e em H2SO4 0,1 mol L-1 e b) aços ferramentas SAE 1045 e X155CrVMo12-1 e as respectivas regiões aço/cermet/níquel-cobre-níquel/aço em solução aquosa de NaCl 0,6 mol L-1 . Na primeira parte, o sistema ferri/ferrocianeto foi estudado por voltametria cíclica (CV) e espectroscopia de impedância eletroquímica (EIS) sobre Pt e carbono vítreo com eletrodos de tamanho convencional e com a microcélula (capilares de 200 e 1200 μm de diâmetro). Os valores de separação dos picos de corrente anódica e catódica e a razão entre as correntes desses picos (ipc/ipa > 0,90) sugerem um processo de eletrodo quase-reversível sem reação química acoplada para todas as condições estudadas. Os valores das funções-corrente mostram diferenças significativas e os coeficientes de difusão diferem em ca. uma ordem de grandeza entre a microcélula e a célula convencional. Espectros de impedância eletroquímica para a microcélula foram similares aos obtidos em eletrodo convencional mostrando uma constante de tempo em alta freqüência associada à transferência de carga e perfil típico de difusão do tipo de Warburg na região de médias freqüências. Em baixas freqüências há um desvio do comportamento esperado para uma difusão do tipo de Warburg. Na segunda parte, os aços ferramenta estudados antes da solda foram SAE 1045, X155CrVMo12-1 (F521) e 90MnCrV8 (F522) usando célula convencional e os dois primeiros também com a microcélula. A microcélula foi usada para os estudos eletroquímicos das regiões aço/cermet/níquel-cobre-níquel/aço formadas pela solda do tipo difusão dinâmica, uma vez que é praticamente impossível preparar um eletrodo com composição semelhante àquela da região de solda. A superfície atacada por solução aquosa de cloreto foi observada em tempo real usando um microscópio. / Two systems were studied using a home made microcell: a) ferricyanide/ferrocyanide in 0.6 mol L-1 KCl and in 0.1 mol L-1 H2SO4, and b) the SAE 1045 and X155CrVMo12-1 tool steels and the corresponding steel/cermet/níquel- copper-nickel/steel interphases in 0.6 mol L-1 NaCl solution. In the first part, the ferri/ferrocynide system was studied by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) on Pt and glassy carbon electrodes with electrodes of conventional size and with a microcell (capillaries of 200 and 1200 µm diameter). For all conditions studied, the anodic and cathodic peak potential difference and the anodic and cathodic current peak ration values suggest a quasi-reversible charge transfer process without coupled chemical reactions. Comparing microcell and conventional cell the current function values showed some significant differences and the diffusion coefficient values are ca. one order of magnitude different each other. Electrochemical impedance spectra were similar for both microcell and conventional cell and were interpreted considering a time constant at high frequencies related to the charge transfer reaction and a typical Warburg type diffusion at middle frequencies region. At low frequencies a deviation from the expected typical Warburg type diffusion was observed. In the second part, the SAE 1045, X155CrVMo12-1 (F521) and 90MnCrV8 (F522) tool steels were studied using a conventional cell and the first two steels also with a microcell. The microcell was mainly used to investigate the steel/cermet/nickel- copper-nickel/steel regions prepared by dynamic diffusion bond, since is almost impossible to prepare an electrode with the same composition of the welding region. The attacked surface by using chloride solution was observed in real time by means of a microscope. Electrochemical and microscopic... (Complete abstract click electronic access below)

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/92054
Date21 January 2009
CreatorsAkita, Adriano Heleno [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Benedetti, Assis Vicente [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format130 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0025 seconds