Return to search

Avaliação de lâminas e cabos de laringoscópios quanto a carga bacteriana/fúngica e presença de sangue = Evaluation of laryngoscope blades and handles regarding bacterial/fungal load and blood presence / Evaluation of laryngoscope blades and handles regarding bacterial/fungal load and blood presence

Orientador: Maria Isabel Pedreira de Freitas Ceribelli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-21T01:00:38Z (GMT). No. of bitstreams: 1
NegrideSousa_AnaClaudia_M.pdf: 10758939 bytes, checksum: 1e275b80f25f5c6d9e3ab12d3eee6c94 (MD5)
Previous issue date: 2012 / Resumo: Lâminas e cabos de laringoscópios têm sido analisados evidenciando presença de sangue, fluídos corpóreos e microrganismos, podendo apresentar-se potencialmente contaminados durante seu uso clínico. A forma de utilização destes equipamentos na prática diária pode estar colocando o paciente e a equipe de saúde em risco devido à maneira como vem sendo feita sua limpeza e desinfecção. Neste estudo estabeleceu-se a hipótese de que a lâmina e o cabo de laringoscópio, prontos para serem usados no paciente, sejam potenciais fontes de contaminação. O objetivo geral foi determinar a presença de sangue e de microrganismos neste equipamento. Foram analisados cabos e lâminas de laringoscópios, prontos para uso, em dois hospitais universitários públicos do interior de São Paulo. A amostra foi definida considerandose os equipamentos prontos para uso nas seções selecionadas em cada hospital, totalizando para análise microbiológica na Instituição I, 42 lâminas e na Instituição II 41 lâminas. Para a fase de presença de sangue, respectivamente, foram avaliadas 48 e 50 amostras, sendo estes distribuidos entre lâminas e cabos de laringoscópios. As análises microbiológicas foram realizadas no Laboratório de Microbiologia da Divisão de Patologia Clínica da Instituição II, utilizando-se técnicas laboratoriais quantitativas e qualitativas. Para a identificação de sangue oculto foi utilizado o teste para o monitoramento de sua presença em superfícies com metodologia em conformidade com a norma EM ISO 15883, com nome comercial de HemoCheck-S®. Os dados foram analisados descritivamente. Os resultados para o teste de sangue oculto nas lâminas e cabos dos laringoscópios foram de 14,3% e 46,0% positivos na Intituição I e II, respectivamente. Para o crescimento de microrganismos na Instituição I o resultado foi positivo para 76,2% das amostras, na Instituição II, um total de 92,7%. Na contagem de UFC mais de 101 UFC foram encontradas em 31,3% amostras na Instiutição I e na Instituição II em 44,7%. O estudo concluiu que a lâminas e o cabos dos laringoscópios nestas duas intituições pesquisadas oferecem riscos aos pacientes, apresentando crescimento de microrganismos e presença de sangue oculto. Urge providências para que seja possível sua utilização, garantindo-se a segurança dos pacientes e dos profissionais que tem contato direto com este equipamento / Abstract: Laryngoscope blades and handles have been analyzed showing the presence of blood, body fluids and microorganisms, which may present as potentially contaminated during its clinical use. The daily practical utilization of devices can be exposing patients and health professionals to risk, due to ineffective cleaning and disinfecting methods. This study established the hypothesis that the laryngoscope blade and handle, when ready to use, are potential sources of contamination. Thus, the overall objective is to determine the presence of microorganisms and blood in the equipment. Laryngoscope handles and blades was analyzed, when ready to use, in two public school hospital in the country side of São Paulo. The sample size was defined considering the equipment readiness in specific areas of each hospital, summarizing 42 blades at institution I and 41 blades at institution II for microbiological analysis. For the presence of blood testing phase, 48 and 50 samples were evaluated respectively, considering laryngoscope blades and handles. Microbiological analysis was performed at the Laboratory of Microbiology, Division of Clinical Pathology, Institution II, using qualitative and quantitative laboratory techniques. For occult blood finding, the surface test methodology in accordance with standard EN ISO 15883 was used, commercial name HemoCheck-S ® and data was analyzed descriptively. The results for occult blood test in the blades and handles of laryngoscopes were positive for 14.3% and 46.0%, for institutions I and II, respectively. For microorganisms' growth test, institution I indicated positive to 76.2% of the samples and institution II showed positive for a total of 92.7% of the samples. For UFC counting, UFC higher than 101 UFC was found in 31.3% of samples for institution I and 44.7% for institution II. This study revealed that the laryngoscope blades and handles of two evaluated institutions shows risks to patients, indicating a growth of microorganisms and the presence of occult blood. Urgent steps should be taken to allow their utilization, guaranteeing the safety of patients and health professionals who have direct contact with this equipment / Mestrado / Enfermagem e Trabalho / Mestre em Ciências da Saúde

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/311017
Date21 August 2018
CreatorsNegri de Sousa, Ana Claudia, 1977-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Freitas, Maria Isabel Pedreira de, 1948-, Ceribelli, Maria Isabel Pedreira de Freitas, 1948-, Sousa, Cristina Paiva de, Moretti, Maria Luiza
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Enfermagem
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format78 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0503 seconds