Return to search

Efeitos da radiofreqüência nas características mecânicas da cápsula anterior do ombro de coelhos / Radiofrequency effects on mechanical characteristics of anterior shoulder capsule of rabbits

INTRODUÇÃO - A literatura mostra a utilização da radiofreqüência como alternativa em casos de redundância ou frouxidão de tecido, podendo ser empregada como solução em alguns casos de instabilidade de ombro. O presente estudo avalia os efeitos mecânicos da radiofreqüência em cápsulas anteriores de ombros de coelhos vivos. MÉTODOS O estudo é comparativo e randomizado, tendo sido realizado em trinta e sete ombros de coelhos, machos, da raça Nova Zelândia, na faixa etária de 4 meses 6 meses, com peso médio de 3kg 250mg, criados para o projeto e mantidos no Biotério Central da Universidade Federal de Pelotas UFPEL - RS. O trabalho consta de dezoito ombros do grupo controle sendo estes abertos para gerar instabilidade e não submetidos ao procedimento de radiofreqüência; e dezenove ombros do grupo experimento (radiofreqüência), abertos para gerar instabilidade e submetidos a radiofreqüência com tempo fixado em 7segundos numa temperatura fixa de 650C, com tecido embebido em solução salina. Após cinqüenta dias de pós operatório, os animais foram levados à eutanásia. O material foi mantido em -21,40C por quinze dias e, após transportado para o Laboratório de Investigação Medica 21 da Universidade de São Paulo USP - SP, para avaliação de nove variáveis: altura, comprimento inicial sem carga, área da cápsula, força máxima, deformação máxima, tensão máxima, deformação relativa, rigidez e módulo de elasticidade. RESULTADOS Foram encontradas diferenças estatisticamente significantes entre os grupos controle e o grupo radiofreqüência, para as variáveis força máxima e rigidez (p<0,05), sendo maiores em média, no grupo controle. CONCLUSÃO Desse modo a força máxima e a rigidez da cápsula anterior de ombros de coelhos vivos, submetidas à radiofreqüência em um único ponto, diminui após cinqüenta dias / INTRODUTION literature presents radiofrequency as an alternative tool to be used in redundancy or tissue looseness cases, and to be employed as a potencial solution for shoulder instability. The present study evaluated the mechanical effects of radiofrequency usage in anterior shoulder capsules of living rabbits. METHODS - the study is comparative and randomized, it was carried out with thirty seven shoulders of male rabbits (New Zealand breed), with ages between 4 to 6 months, weighing on average 3kg250g that were raised for the project and kept at Central Biotery from Federal University of Pelotas RS. The study groups encompassed eighteen shoulders as a control group that were operated to generate instability but were not submitted to radiofrequency procedure; and nineteen shoulders as intervention group (radiofrequency), that underwent the same operation procedure but were submitted to radiofrequency by the period of seven seconds at a steady temperature of 650C, the tissue was Embedded in salt solution. Fifty days after surgery the rabbits were taken to euthanasia. The material was kept at - 21,40C for fifteen days and later was taken to the São Paulo University-USP Medical Investigation Laboratory(#21), for the assessment of nine variables: height, unloaded inicial length, capsule area, maximum strength, maximum deformation, maximum tension, relative deformation, stiffness and elasticity module. RESULTS Statistical differences were observed between groups concerning maximum strength and stiffness(p<0.05), that were higher on average in the contrl group. CONCLUSION Maximum strength and stiffness of the anterior shoulder capsule in living rabbits, submitted to radiofrequency in a single spot, decreases after fifty days

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-19022009-105540
Date17 July 2007
CreatorsJosé Luiz Pozo Raymundo
ContributorsOlavo Pires de Camargo, Gilberto Luis Camanho, Eduardo da Frota Carrera, Marcos Antonio Almeida Matos, Carlos Eduardo Sanches Vaz
PublisherUniversidade de São Paulo, Ortopedia e Traumatologia, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds