Objetivos: Avaliar o comportamento da pressão arterial sistólica (P AS) e diastólica (P AD) em mulheres hipertensas usuárias de anticoncepcionais. Delineamento: Estudo observacional, analítico, de delineamento transversal, prospectivamente planejado. Métodos: Foram estudados 171 pacientes, entre 18 e 50 anos, que consultaram no Ambulatório de Hipertensão do Hospital de Clínicas de Porto Alegre. A amostra compreendeu 66 usuárias atuais de anticoncepcionais orais, 26 usarias de outros métodos de contracepção e 79 pacientes que nunca realizaram qualquer forma de contracepção. Todas as pacientes foram submetidas a avaliação inicial de rotina do ambulatório e os dados foram coletados através de questionário padronizado. A pressão arterial foi aferida de acordo com normas técnicas e classificada segundo a média de 6 determinações. Pacientes usuárias de anticoncepcionais orais foram comparadas a usuárias de outros métodos e a pacientes sem contracepção e, em algumas análises, a não-usuárias de anticoncepcionais orais (outros métodos e sem contracepção). Os desfechos principais foram a PAS e a PAD nos diferentes grupos de comparação e a prevalência de hipertensão (P AS ~ 140 e P AD ~ 90 mmHg) entre usuárias e não-usuárias. Resultados: A amostra constituiu-se predominantemente de mulheres brancas, obesas e hipertensas leves com diagnóstico de hipertensão há aproximadamente 6 anos. A média de idade foi de 41 (± 6,9) anos, sendo significativamente menor nas usuárias de anticoncepcional oral. APAD foi maior nas usuárias de anticoncepcional oral em comparação aos outros grupos (P = 0, 016). Em relação à duração de uso do anticoncepcional oral, observou-se que usuárias há mais de 8 anos apresentavam níveis pressóricos significativamente maiores, mesmo após ajuste para idade. Houve tendência para menor controle da pressão arterial (P AS < 140 e P AD < 90 mmHg) nas usuárias de anticoncepcionais orais (P para tendência= 0,046) e uma maior proporção de hipertensas moderado-grave (estágio 2 e 3 do JNC VI) nesse grupo, diferenças que não decorriam de menor freqüência de uso de anti-hipertensivos. Observou-se associação independente de idade, índice de massa corporal e uso de anti-hipertensivos entre a P AD e uso de anticoncepcionais orais e tendência para associação com a P AS. Na regressão logística, controlando-se para os mesmos vieses potenciais, verificou-se associação independente e significativa do uso de anticoncepcionais orais com hipertensão arterial sistêmica. Conclusões: O uso de anticoncepcionais orais em mulheres hipertensas associa-se com aumento da pressão arterial diastólica e tendência a menor controle da pressão arterial. A associação entre uso de anticoncepcionais orais e a probabilidade de não ter a pressão arterial normalizada independe de idade, peso e tratamento com anti-hipertensivos. / Objectives: To assess the association between systolic and diastolic blood pressure (SBP and DBP) and use of of oral contraceptives (OCP) in hypertensive women referred for evaluation and treatment of hypertension. Design: A prospectively planned cross-sectional study. Methods: W e studied 171 women, between 18 and 50 years, who were referred to the hypertensive outpatient clinic of the Clinicai Pharmacology Division of the Hospital de Clínicas de Porto Alegre. The sample was composed by 66 current users of oral contraceptives, 26 users o f other contraceptive methods (TIJD, condom, comportamental methods) and 79 women who had never done any kind of contraception. Ali patients were submitted to a routine evaluation and data was collected in a standard protocol. Blood pressure was determined according to standard recommendations and the average of six blood pressure readings was used to establish the usual blood pressure of these patients. Current users o f OCP were compared with users o f other methods and with patients without any kind of contraception; in some analysis, the former was compared with non-users ( other methods plus no contraception).The main outcome measures were systolic and diastolic blood pressures among the different groups and the prevalence o f uncontrolled hypertension (SBP > 140 mmHg and DBP > 90 mmHg). Results: The sample was constituted predominantly by middle-aged (mean 41; ±6,9), overweight white women, with mild hypertension for approximately 6 years. Age was significantly lower in current users of OCP. Diastolic blood pressure was higher in OCP users than the observed in other groups (P = 0,016). In terms of duration of OCP use, we observed that users of OCP for more than 8 years had age adjusted higher blood pressure leveis when compared with women with lower length of use. There was trend for poor blood pressure control (P for trend = 0.046) and a higher proportion of moderate-severe hypertension among OCP users. These results were independent of use of antihypertensive drugs by patients from the comparison groups. The association between DBP (anda trend for SBP) with current use of OCP was not biased by age, body mass index and use of antihypertensive drugs. In a logistic regression model, controlling for the same confounding factors, we found that current use of OCP was independently and significantly associated with the prevalence of uncontrolled hypertension. Conclusions: Hypertensive women using OCP have a significant increase in diastolic blood pressure and a trend for poor blood pressure control. The association between current use of OCP and uncontrolled blood pressure was indepedent of age, weight and antihypertensive drug treatment.
Identifer | oai:union.ndltd.org:IBICT/oai:lume.ufrgs.br:10183/139240 |
Date | January 1999 |
Creators | Lubianca, Jaqueline Neves |
Contributors | Fuchs, Flávio Danni |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Biblioteca Digital de Teses e Dissertações da UFRGS, instname:Universidade Federal do Rio Grande do Sul, instacron:UFRGS |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0134 seconds