Return to search

Avaliação dos níveis de metaloproteinases da matriz no fluido gengival durante a movimentação dentária ortodôntica / Evaluation of the matrix metalloproteinases levels in the gingival crevicular fluid during orthodontic tooth movement

Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / Durante o tratamento ortodôntico, a resposta inicial dos tecidos periodontais ao estímulo mecânico envolve várias alterações estruturais e bioquímicas que permitem a movimentação do dente. As metaloproteinases da matriz (MMPs) parecem desempenhar um papel importante na manutenção da integridade funcional da matriz extracelular periodontal. O objetivo do presente estudo foi avaliar, em diferentes intervalos de tempo, os níveis de metaloproteinases da matriz -1, -2, -3, -7, -8, -12 e -13 no fluido gengival (FG) de caninos superiores submetidos ao movimento de distalização e testar a hipótese de possíveis alterações nos níveis destas MMPs com o emprego de forças ortodônticas. Amostras de FG foram obtidas de dezesseis pacientes ortodônticos saudáveis (nove do sexo masculino e sete do sexo feminino, com idades entre 13 e 27 anos, média de idade 17,7 anos) que possuíam indicação de exodontias dos primeiros pré-molares superiores e tiveram os caninos distalizados como parte da terapia ortodôntica. Um dos caninos superiores foi distalizado ortodonticamente, sendo considerado dente teste. O canino contralateral não foi submetido a nenhuma força, no entanto foi incluído na aparatologia ortodôntica e utilizado como controle. A coleta de FG foi realizada nos sítios mesial (tensão) e distal (pressão) dos dentes testes e controles 7 dias antes da montagem da aparatologia ortodôntica, imediatamennte após a aplicação da força ortodôntica, e após 1 h, 24 h, e 7, 14 e 21 dias, respectivamente denominados -7d, 0h, 1h, 24h, 7d, 14d e 21d. A arcada superior de cada paciente foi dividida em um lado teste e um lado controle. Os resultados mostraram que foram encontradas diferenças significativas no volume do FG apenas nos intervalos de tempo entre -7d e 0h nos lados controle-pressão (CP), teste-tensão (TT) e teste-pressão (TP). Em TP foi observado ainda aumento do volume entre os tempos 0h e 14d. Foi possível detectar no FG as MMPs estudadas nos lados controle/teste e lados pressão/tensão, em todos os intervalos de tempo. As flutuações dos níveis das MMPs apresentaram poucas alterações significativas nos diferentes intervalos de tempo, nos lados controle/teste e lados pressão/ tensão. As diferenças intergrupos (TT, TP, CT e CP) em cada tempo não mostraram resultados significativos assim como as comparações entre os lados pressão e tensão para cada tempo individualmente. Os níveis de expressão da MMP-8 foram muito superiores aos das outras MMPs avaliadas, porém sem diferenças signficativas entre os lados teste e controle. / During orthodontic treatment, the initial response of periodontal tissues to mechanical stress involves several structural and biochemical changes that allow the tooth movement. The matrix metalloproteinases (MMPs) seem to play an important role in maintaining the functional integrity of periodontal extracellular matrix. The aim of this study was to evaluate, in different periods, the levels of matrix metalloproteinases -1, -2, -3, -7, -8, -12 and -13 in gingival crevicular fluid (GCF) of the superior caninessubmitted to distalization movement and test the hypothesis of possible changes in these MMPs levels with the use of orthodontic forces. GCF samples were obtained from sixteen healthy orthodontic patients (nine males and seven females with ages ranging between 13 and 27 years, mean age 17.7 years) who had indication of first superior bicuspids extraction with cuspids distalization as part of orthodontic treatment. One maxillary canine was subjected to a distalizing force, and considered as the test tooth. The contralateral canine, which was not subjected to any force but was included in an orthodontic appliance, was used as a control. GCF sampling was performed at both mesial (tension) and distal (pressure) sites of the controls and tests teeth 7 days before applying the orthodontic appliance, immediately before applying the orthodontic force, and after 1 h, 24 h, and 7, 14 and 21 days, respectively called -7d, 0h, 1h, 24h, 7d, 14d and 21 d. The results showed significant differences in the GCF volume only in time intervals of 0h-7d on control-pressure (CP), test-tension (TT) and test-pressure (TP) sides. In TP side was observed an increase in volume between the time 0h and 14d. It was possible to detect in GCF all MMPs studied on control/test sides and pressure/tension sides at all periods. Fluctuations in levels of MMPs showed few significant changes in different periods on the sides control/test and pressure/tension. The differences between the groups (TT, TP, CT and CP) in each time showed no significant results as well as the comparisons between pressure and tension sides for each period individually. The expression levels of MMP-8 were much higher than those of other MMPs evaluated, but with no significant differences between sides test and control.

Identiferoai:union.ndltd.org:IBICT/urn:repox.ist.utl.pt:UERJ:oai:www.bdtd.uerj.br:1799
Date30 March 2010
CreatorsCristiane Canavarro Rodrigues Martins
ContributorsJonas Capelli Júnior, Ricardo Palmier Teles, Marco Antonio de Oliveira Almeida, Raphael Hirata Júnior, José Nelson Mucha, Carlos Marcelo da Silva Figueredo, Robert Willer Farinazzo Vitral
PublisherUniversidade do Estado do Rio de Janeiro, Programa de Pós-Graduação em Odontologia, UERJ, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Formatapplication/pdf
Sourcereponame:Biblioteca Digital de Teses e Dissertações da UERJ, instname:Universidade do Estado do Rio de Janeiro, instacron:UERJ
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds