Comparação de grandezas cefalométricas obtidas por meio de telerradiografias e tomografias computadorizadas multislice em crânios secos humanos. / Cephalometric measurement comparison from data obtained by multislice computed tomography and cephalometric radiography in dry human skulls.

Proposição: O objetivo deste trabalho foi comparar medidas cefalométricas lineares obtidas por meio de telerradiografias em normas lateral e frontal, com medidas obtidas com tomografia computadorizada multisclice em terceira dimensão (3D-TC), verificar a acurácia na comparação com o padrão ouro (medidas físicas) e checar a precisão intra-examinador e interexaminadores na localização de 10 pontos cefalométricos. Material e métodos: A amostra estudada consistiu de crânios humanos secos (n=10). As telerradiografias foram obtidas no Departamento de Ortodontia e Odontopediatria da Faculdade de Odontologia da USP, por meio de um aparelho Yoshida Dental, modelo Panoura, e as imagens de 3D-TC foram adquiridas por meio de um tomógrafo computadorizado multilsice de 16 canais, (Aquilion® ? Toshiba) pertencente ao Instituto do Coração de São Paulo, utilizando um protocolo com espessura de corte de 0,5 mm e intervalo de reconstrução de 0,3 mm. Os dados originais foram transferidos para uma estação de trabalho independente com o programa de visualização volumétrica Vitrea®, onde as medidas foram realizadas em terceira dimensão e com o auxílio das reconstruções multiplanares, para permitir a comparação com as medidas realizadas a partir das telerradiografias em normas lateral e frontal, com o auxílio do software Dolphin®. Resultados e Conclusões: As medidas obtidas por meio da 3D-TC apresentaram erros intra-examinador e interexaminadores insignificantes em termos absolutos (mm) e percentuais e, correlações intraclasse elevadas com intervalos de confiança estreitos, para todas as medidas. Com relação à acurácia, a 3D-TC apresentou valores elevados para as correlações intraclasse e intervalos de confiança (95%) estreitos nas comparações com o padrão ouro, para todas as medidas. A técnica que emprega a cefalometria radiográfica convencional apresentou imprecisão para a medida da grandeza Zm(d)- Zm(e) e inacurácia com relação ao padrão-ouro para todas as medidas, com exceção da medida da grandeza Co-Gn, que se mostrou precisa e acurada. A tomografia computadorizada multislice se mostrou mais precisa e acurada do que as telerradiografias em normas lateral e frontal, de forma estatisticamente significante, para a obtenção de medidas em crânios secos. / Proposition: The purpose of this study was to compare linear cephalometric measurements obtained by means of lateral and frontal conventional cephalograms, within measurements obtained by means of a multislice computed tomography in third dimension (3D-CT), verify its accuracy in comparison with the gold-standard (direct physical measurements) and verify the preciseness intra-observer and interobserver for locating 10 cephalometric landmarks. Material and Methods: The sample under investigation was constituted by dry human skulls (n=10). The conventional cephalograms, were taken in the department of orthodontics and pediatric dentistry in the School of Dentistry ? São Paulo University, utilizing a Panoura® X-ray equipment (Yoshida Dental) and the 3D-CT images were obtained utilizing a 16 channel MSCT scanner (Aquilion® - Toshiba) located in the ?Instituto do Coração de São Paulo? (School of Medicine/University of São Paulo). The acquisition parameter was 0,5 mm slice thickness by 0,3 slice rendering. The raw data was transferred to an independent workstation containing the Vitrea® software, where the measurements were made in 3D and aided by multiplanar reformations for posterior comparison with those measurements made over the lateral and frontal conventional cephalograms, using the software Dolphin®. Results and Conclusions: The averages of measurements obtained from 3D-CT were consistently precise and accurate. They shown higher ICC values and short intervals of confidence (95%) in comparison with the gold-standard, in addition, the intra-observer and inter-observer error, were low in absolute (mm) and percent terms. Regarding the conventional cephalograms, the measurement Zm(d)-Zm(e) shown lack of preciseness for intra-observer and interobserver. Were also noticed an inaccuracy for all measurements, in comparison with the gold standard, excepting for the Co-Gn measurement, that presented preciseness and accuracy for both observers. The multislice computed tomography is a reliable method and was statistically significant, more precise and accurate for cranial measurements than the conventional cephalograms.

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-17052007-145601
Date28 March 2007
CreatorsAccorsi, Mauricio Adriano de Oliverio
ContributorsRino Neto, José
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguagePortuguese
TypeDissertação de Mestrado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.002 seconds