Yes / Reverse Osmosis (RO) is widely used for separating organic and inorganic pollutants in wastewater. In this research, the one-dimensional steady state model of a spiral wound RO for the removal of phenol from wastewater, was simulated using gPROMS software to identify optimal design and operating parameters. The design parameters included the membrane length, width and feed spacer channel and operating conditions included temperature and pressure of the RO process. The optimal design parameters were able to maximise the removal of phenol from wastewater. The simulation results showed that the removal of phenol from wastewater was significantly influenced by the combination of membrane width, operating pressure, and feed temperature. The four main parameters (permeate concentration, solute flow, solute rejection, and water flux) that govern the performance of a reverse osmosis membrane were found to be influenced by the design and operating conditions.
Identifer | oai:union.ndltd.org:BRADFORD/oai:bradscholars.brad.ac.uk:10454/19191 |
Date | 18 October 2022 |
Creators | Khan, Shamraze, Al-Obaidi, Mudhar A.A.R., Kara-Zaitri, Chakib, Mujtaba, Iqbal |
Source Sets | Bradford Scholars |
Language | English |
Detected Language | English |
Type | Article, Published version |
Rights | © 2022 The Author(s). Published by Elsevier B.V. on behalf of Institution of Chemical Engineers. Under a Creative Commons license (https://creativecommons.org/licenses/by-nc-nd/4.0/)., CC-BY-NC-ND |
Page generated in 0.0013 seconds