Return to search

Análise de corpos de prova mandibulares utilizados para avaliação de sistema de fixação óssea = Analysis of mandibular test specimens used to assess a bone fixation system / Analysis of mandibular test specimens used to assess a bone fixation system

Orientador: Luis Augusto Passeri / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-21T21:56:10Z (GMT). No. of bitstreams: 1
Baccarin_LeandroStocco_M.pdf: 2096681 bytes, checksum: 04979b5f15938f19353542ca48c4d46d (MD5)
Previous issue date: 2013 / Resumo: Objetivo: O objetivo deste trabalho é avaliar, por meio de testes biomecânicos, se materiais sintéticos diferentes, empregados para a confecção de corpos de prova apresentam comportamento biomecânico diferente, em comparação aos demais, ao simular in vitro a resistência ao carregamento de um método de fixação consagrado para OSRM. Material: 30 réplicas de hemimandíbulas humana, sintéticas e padronizadas, com OSRM, divididas em três grupos de 10 amostras cada: Grupo A - plástico ABS, Grupo B - Poliamida, e Grupo C - Poliuretano. Estas foram fixadas por três parafusos bicorticais posicionais (16 mm de comprimento, sistema 2.0 mm), em disposição "L" invertido, utilizando-se guias de perfuração e avanço de 5 mm. Métodos: Cada amostra foi submetida ao carregamento linear vertical e os valores de resistência ao carregamento registrado em 1, 3, 5, 7 e 10 mm de deslocamento. As médias e desvio padrão foram comparados, empregando-se análise de variância (p<0.05) e pelo teste Tukey. Resultados: Notou-se uma tendência de menores valores no grupo B em relação aos grupos A e C. Nos deslocamentos 3 e 5 mm, houve uma diferença entre os grupos A e C para o grupo B (p<0.05). Nos deslocamentos 7 e 10 mm houve diferença entre os 3 grupos sendo os maiores valores encontrados no grupo C e os menores no grupo B (p<0.05). Conclusões: Levando-se em consideração os resultados obtidos e o comportamento de cada material utilizado como substrato, podemos considerar que ocorreram diferenças significativas entre os materiais, quando comparados entre si / Abstract: Purpose: The aim of this study was to assess through biomechanical testing if different synthetic materials used to fabricate test specimens have a different biomechanical behavior in comparison with other materials when simulating in vitro load resistance of a fixation method established for SSRO. Material: Thirty synthetic and standardized human hemimandible replicas with SSRO were divided into three groups of 10 samples each. Group A - ABS plastic; Group B - Polyamide and Group C - Polyurethane. These were fixated with three bicortical position screws (16 mm in length, 2.0mm system) in an inverted L pattern using perforation guide and 5 mm advancement. Methods: Each sample was submitted to linear vertical load and load strength values were recorded at 1, 3, 5, 7 and 10 mm of displacement. The means and standard deviation were compared using the Analysis of Variance (p<0.05) and the Tukey's test. Results: A tendency for lower values was observed in Group B in comparison with Groups A and C. At 3 and 5 mm of displacement, a difference between Groups A and C was found in comparison with Group B (p<0.05). At 7 and 10 mm of displacement a difference was found among the 3 groups, in which Group C showed the highest values and Group B the lowest (p<0.05). Conclusions: Taking into consideration the results obtained and the behavior of each material used as a substrate, significant differences occurred among the materials when compared among them / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/310497
Date21 August 2018
CreatorsBaccarin, Leandro Stocco, 1978-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Passeri, Luis Augusto, 1957-, Silva, Jorge Vicente Lopes da, Etchebehere, Maurício
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Ciências da Cirurgia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format52 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0155 seconds