Previous issue date: 2015-05-31 / CAPES / FACEPE / No presente trabalho, foi realizado um levantamento das doses recebidas por pacientes
pediátricos, em exames radiográficos convencionais dos seios da face, realizados no Recife, PE. Para a realização do estudo, foram selecionados dois hospitais que atendem ao Sistema Único de Saúde, com alta demanda de exames pediátricos. Os dados dos pacientes e os parâmetros de irradiação utilizados em 159 exames radiográficos dos seios da face de crianças, com idades entre 0 e 15 anos, foram coletados, sendo 103 radiografias realizadas na projeção lateral (radiografia cavum) e 56 radiografias realizadas nas projeções pósteroanteriores em fronto-naso (FN) e mento-naso (MN) (radiografias Caldwell e Waters, respectivamente). Inicialmente, foram efetuadas as avaliações de desempenho dos dois equipamentos de raios X pertencentes aos hospitais. A partir dos valores dos rendimentos dos tubos de raios X e dos parâmetros de irradiação empregados nos exames, foram estimados os valores de kerma no ar na superfície de entrada (Ka,e) e produto kerma no ar-área (PK,A). Os
valores de kerma no ar nas regiões dos olhos e da tireoide foram estimados utilizando
dosímetros termoluminescentes (TLD-100). As doses absorvidas médias nos órgãos e a dose efetiva foram estimadas com o software PCXMC® a partir dos dados antropométricos, parâmetros de irradiação e do kerma no ar incidente (Ka,i), obtido com o rendimento. Os resultados mostraram que os valores de Ka,e variaram entre 0,065 mGy e 1,113 mGy, para radiografias cavum, entre 0,13 mGy e 7,99 mGy, para radiografias na incidência Caldwell e entre 0,13 mGy e 10,12 mGy, para radiografias na incidência Waters. Os valores do kerma no ar na região dos olhos variaram entre 0,001 mGy e 0,968 mGy, nas radiografias cavum, e 0,011 mGy e 0,427 mGy, nas incidências Caldwelll e Waters (conjuntamente). Na região da tireoide, os valores de kerma no ar variaram entre 5 μGy e 932 μGy, para as radiografias cavum, e 2 μGy e 972 μGy, para as incidências Caldwell e Waters. 90% dos valores de Ka,e estimados para os exames realizados no Hospital B encontram-se dentro do recomendado pela
comunidade britânica, enquanto todos no Hospital A encontram-se acima. O fato do Hospital B apresentar valores de Ka,e dentro do aconselhado não significa que seu serviço esteja otimizado, devido a grande quantidade de filmes rejeitados, cuja imagem apresentava-se clara e inapropriada para o diagnóstico, elevando a dose final recebida pelo paciente pela repetição do exame. Os altos valores de Ka,e devem-se, principalmente, à utilização indiscriminada da grade antiespalhamento, não recomendada para pacientes desta idade. Os valores de PK,A variaram entre 5,7 mGy.cm2 e 92,3 mGy.cm2 para as radiografias cavum, entre 24,4 mGy.cm2 e 340,3 mGy.cm2 para as radiografias Caldwell e, entre 34,0 mGy.cm2 e 378,3 mGy.cm2 para as radiografias Waters. A partir dos dados pode-se concluir que há necessidade de otimização dos procedimentos radiográficos. / In this study, a survey was conducted in order to assess doses received by pediatric patients ongoing conventional radiographs of the sinuses, performed in Recife, PE. For the study, two hospitals of SUS (Sistema Único de Saúde), with high demand for pediatric examinations, were selected. Patient data and irradiation parameters were collected for 159 radiographs of the children’s sinuses with ages between 0 and 15. Among those, 103 radiographs were taken on the lateral projection (cavum radiography) and 56 radiographs were taken in posteroanterior projections in fronto-naso (FN) and mento-naso (MN) (Caldwell and Waters radiographs, respectively). Initially, the performance of the two X-ray equipment was evaluated. Air kerma values at the entrance surface (Ka,e), and air kerma area product (PK,A) were estimated using X-ray tubes output and irradiation parameters used in the examinations. Air Kerma values on the eyes and thyroid were estimated using thermoluminescent dosimeters (TLD-100). The average absorbed organ doses and effective dose were estimated at the PCXMC® software using the anthropometric data, irradiation parameters and the incident air kerma (Ka,i) obtained with the x-ray tube output. The results showed that Ka,e values varied between 0.065 and 1.113 mGy for cavum radiographs; between 0.13 and 7.99 mGy for Caldwell’s view; and between 0.13 and 10.12mGy for Waters’ view. The air kerma values in at the eye region varied from 0.001 mGy to 0.968 mGy for cavum radiographs, and from 0.011 mGy to 0.427 mGy for Caldwell and Waters’ views (together). In the thyroid region air kerma values ranged from 5 μGy to 932 μGy for cavum view and from 2 μGy to 972 μGy for Caldwell and Waters’ views. Tests performed at Hospital B have shown that 90% of the Ka,e values estimated during exams are within the recommended values by British Commonwealth, while all the Ka,e values in the Hospital A were above it. However,
even though Hospital B presented Ka,e values within recommended values, this service was not optimized, due to the large amount of rejected films, whose image were inappropriate for diagnosis resulting in increased dose by the patient re-examination. The high Ka,e values are due mainly to the indiscriminate use of anti-scatter grid, not recommended for patient ages assessed in this study. PK,A values varied between 5.7 and 92.3 mGy.cm2 for cavum radiographs, between 24.4 and 340.3 mGy.cm2 for Caldwell’s view and between 34.0 and 378.3 mGy.cm2 for Waters’ view. Thus, it was concluded that there is need for optimization of radiographic procedures.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufpe.br:123456789/16747 |
Date | 31 May 2015 |
Creators | PINTO, Beatriz Villa-‐Chan Cantalupo |
Contributors | KHOURY, Helen Jamil, AMÂNCIO, Francisco Fernandes |
Publisher | Universidade Federal de Pernambuco, Programa de Pos Graduacao em Engenharia Biomedica, UFPE, Brasil |
Source Sets | IBICT Brazilian ETDs |
Language | Breton |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFPE, instname:Universidade Federal de Pernambuco, instacron:UFPE |
Rights | Attribution-NonCommercial-NoDerivs 3.0 Brazil, http://creativecommons.org/licenses/by-nc-nd/3.0/br/, info:eu-repo/semantics/openAccess |
Page generated in 0.0029 seconds