Dispositivo fisioterapêutico gerador de pressão positiva expiratória com propriedades fluxo-dependentes / Physiotherapy device positive expiratory pressure generator with flow-dependent properties

Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-12-28T14:09:43Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DispositivoFisioterapeuticoGerador.pdf: 908101 bytes, checksum: f84a5b2428f1c1d5c266fa2ce5096306 (MD5) / Approved for entry into archive by Irvana Coutinho (irvana@ufpa.br) on 2018-01-03T12:33:15Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DispositivoFisioterapeuticoGerador.pdf: 908101 bytes, checksum: f84a5b2428f1c1d5c266fa2ce5096306 (MD5) / Made available in DSpace on 2018-01-03T12:33:15Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertacao_DispositivoFisioterapeuticoGerador.pdf: 908101 bytes, checksum: f84a5b2428f1c1d5c266fa2ce5096306 (MD5)
Previous issue date: 2016-12-21 / A terapia com pressão expiratória positiva (PEP) é segura e eficaz para a prevenção, reversão de atelectasias e remoção de secreções pulmonares. O estudo experimental objetivou elaborar um dispositivo fisioterapêutico capaz de gerar pressão expiratória positiva para pacientes em respiração espontânea e avaliar seu desempenho mecânico. A composição do dispositivo fisioterapêutico constituiu de 14 componentes, produzido em alumínio e plástico, permitindo apresentar características de um resistor fluxo-dependente não gravitacional. As pressões, obtidas por meio do fluxômetro de alto fluxo modelo Certifier® FA TSI (TSI Corporated, EUA), tiveram influência da resistência de orifício com diâmetros de 1,5; 2,0; 3,0; 4,0 e 5,0mm, dos pesos de cinco pistões (1,5; 1,6; 2,0; 3,2 e 3,8g) e de fluxos constantes de 3, 5, 6, 9, 10 e 12L/min ou fluxo de disparo do pistão. Dentre que os cinco pistões, o pistão 4 (3,2g) apresentou melhor resultado estatisticamente significativo, alcançando uma pressão de 20cmH2O com fluxos de 8,16L/min, para o orifício de 1,5mm de diâmetro. O dispositivo de PEP proposto pode gerar pressões terapêuticas entre 10 e 20cmH2O, por meio de uma variação de fluxos expiratórios baixos. Apresenta como característica singular a associação do diâmetro do orifício com o peso do pistão para gerar a pressão positiva. Estudos futuros são necessários a fim de promover a validação do dispositivo fisioterapêutico em crianças saudáveis e posterior análise em pacientes com afecções pulmonares, para obter dados científicos que representem a nossa prática clínica. / Positive expiratory pressure therapy is safe and effective for the prevention, reversal of atelectasis and removal of pulmonary secretions. The experimental study aimed to elaborate a physiotherapeutic device capable of generating positive expiratory pressure for patients in spontaneous breathing and evaluating their mechanical performance. The composition of the physiotherapeutic device consisted of 14 components, produced in aluminum and plastic, allowing to present characteristics of a flow-dependent non-gravitational resistor. The pressures obtained through the high flux flowmeter model Certifir® FA TSI (TSI Corporated, USA) had influence of the orifice strength with diameters of 1.5, 2.0, 3.0, 4.0 and 5.0mm, five-piston weights (1.5; 1.6, 2.0, 3.2 and 3.8g) and constant flows of 3, 5, 6, 9, 10 and 12L/min or piston firing flow. Among the five pistons, the piston 4 (3.2g) presented a better statistically significant result, reaching a pressure of 20cmH2O with flows of 8.16L/min, for the 1.5mm diameter bore. The proposed PEP device can generate therapeutic pressures between 10 and 20cmH2O, through a variation of low expiratory flows. It presents as singular characteristic the association of the diameter of the orifice with the weight of the piston to generate the positive pressure. Future studies are needed in order to promote the validation of the physiotherapeutic device in healthy children and subsequent analysis in patients with pulmonary conditions to obtain scientific data that represent our clinical practice.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/9354
Date21 December 2016
CreatorsNINA, Janize Costa
ContributorsSILVA, Luiz Carlos Santana da, NORMANDO, Valéria Marques Ferreira
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Oncologia e Ciências Médicas, UFPA, Brasil, Núcleo de Pesquisas em Oncologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA