Return to search

Analise tridimensional da distribuição de tensões na estrutura do sistema barra/clips e interface osso/implante em função do tipo de material da barra e do desajuste vertical aos implantes / 3d analysis of stress distribuition on bar/clips structure and bone implant interface due to bar material and vertical misfit to dental implant

Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T05:13:45Z (GMT). No. of bitstreams: 1
Abreu_RicardoTeixeira_D.pdf: 11695187 bytes, checksum: 1c61217f27d7d7cc3554126159572197 (MD5)
Previous issue date: 2007 / Resumo: Este trabalho verificou tridimensionalmente a distribuição de tensões na estrutura e interface osso/implante do sistema barra/clips sobre dois implantes osseointegrados quando influenciada pelo tipo de material da barra (Liga de Au tipo III, liga de AgPd, liga de CoCr e Ti cp) e por diferentes níveis de desajuste vertical da barra a um dos implantes (5Xm, 25Xm, 50Xm, 100Xm, 200Xm e 300Xm) utilizando a metodologia através dos elementos finitos. Com o uso do programa Rhinoceros® 3.0 (NURBS Modeling for Windows, EUA), foram modelados digitalmente dois implantes Máster Screw (Conexão, Brasil) de 10 mm de comprimento, 3,75 mm de diametro de rosca e 4,1 mm de plataforma; um sistema barra/clips com dois UCLAs sem anti-rotacional (Conexão, Brasil); e uma região anterior de mandíbula com severa reabsorção óssea. O conjunto modelado foi exportado para o programa NEiNastran® 9.0 (Noran Engineering Inc., EUA) onde foram realizadas as simulações mecânicas com carregamento de 20 N/cm durante o aperto dos parafusos de retenção da barra. Os resultados obtidos foram avaliados de forma qualitativa através do gradiente de cores das tensões de von Mises e quantitativamente através do registro de três nos que apresentaram maiores níveis de tensão, localizados na barra metálica (no 470), osso cortical (no 5581) e osso medular (no 10683). Na analise qualitativa foi possível observar uma redução de tensão localizada na porção mesial da região cervical, com aumento equivalente de tensão na porção distal da região cervical do osso cortical, osso medular e barra. Na analise quantitativa os maiores e menores níveis de tensão registrados no no 470 foram 1186 MPa no desajuste de 300Xm para a liga de CoCr e 03 MPa no desajuste de 5Xm para a liga de Au tipo III. Para o no 5581, foram registrados 255 MPa no desajuste de 5Xm para a liga de Au tipo III e 225 MPa no desajuste de 300Xm para a liga de CoCr. O no 10683 registrou 215 MPa no desajuste de 300Xm para a liga de CoCr e 201 MPa no desajuste de 5Xm para a liga de Au tipo III. Foi possível concluir que o modulo de elasticidade do material da barra e o desajuste influenciaram de forma significativa as tensões registradas na barra, sem, no entanto, apresentar grande influencia na tensão gerada na interface osso/implante / Abstract: This study evaluated the 3d stress distribution around a bar/clips overdenture system on two osseointegrated implants when influenced by bar material (type III Au alloy, AgPd alloy, cp Ti and CoCr alloy) and different vertical misfit to one of the implants (5Xm, 25Xm, 50Xm, 100Xm, 200Xm e 300Xm) using finite element methodology. Using Rhinoceros® 3.0 software (NURBS Modeling for Windows, EUA), there were digitally made two Master Screw implants (Conexao, Brazil) of 10 mm width, 3.75 mm thread diameter and 4.1 mm fit platform; a bar/clips overdenture system with two UCLAs (Conexao, Brazil); and an anterior part of a severed reabsorbed jaw. The modeled set was then exported to NEiNastran® 9.0 software (Noran Engineering Inc., EUA) where the mechanic simulations were made with the screw tightened to a torque of 20 N/cm. The obtained data were evaluated by qualitative and quantitative means. The qualitative analysis was evaluated by color scale given by the program. At this analysis waspossible to observe a stress reduction at the mesial portion of the cervical region, with equivalent raising stress of the distal portion of this same region, spongy bone and overdenture bar. The quantitative analysis was measured by von Mises stress registered on three knots that showed most stress on qualitative analysis. The three knots were located at the overdenture bar (knot 470), cortical bone (knot 5581) and spongy bone (knot 10683). The greatest and smallest stress levels recorded on knot 470 were 1186 MPa at 300Xm misfit for CoCr alloy and 03 MPa at 5Xm misfit for Au type III alloy. At knot 5581, there were registered 255 MPa at 5Xm for Au type III alloy and 225 MPa at 300Xm for CoCr alloy. The 10683 knot registered 215 MPa at 300Xm for CoCr alloy and 201 MPa at 5Xm for Au type III alloy. The elastic module of the overdenture bar and misfit influenced the stress distribution at the overdenture bar itself, although it did not have great influence at the bone/implant interface / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289908
Date15 February 2007
CreatorsAbreu, Ricardo Teixeira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Mesquita, Marcelo Ferraz, 1967-, Pellizzer, Eduardo Piza, Noritomi, Pedro Yoshito, Consani, Rafael Leonardo Xediek
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format71p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds