Radiotherapy can be highlighted as one possible treatment of cancer. From this point of view, the planning system for radiotherapic treatment is crucial. In order to check the software for the computerized planning of the Cobalt-60 equipment, a series of tests was defined following the standards given by the: TEC DOC 1151 protocol " Aspectos Físicos da Garantia de Qualidade em Radioterapia, Protocolo de Controle de Qualidade (TEC DOC 1151, 2000), o Technical Reports Series Number 430 (TRS 430) (IAEA, 2004), o TRS 398 Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water (TRS 398, 2004). The depth dose of interest of the acrylic simulators used to control the quality of computerized tomography were evaluated, tests of the software and hardware as well as the input and output of data were analyzed, tests of the boundary conditions, of the percetual dose and of the field profile were also performed. An analysis of the results show that the performance of the software results was satisfactory. The only deviattions appeared in the field profile tests that do not fulfilled the expectations due to the limitations of the system. / A radioterapia pode ser destacada como uma possibilidade de tratamento de câncer. Partindo deste propósito, o sistema de planejamento para o tratamento radioterápico é muito importante. Com a finalidade de averiguar o software de planejamento computadorizado do equipamento de Cobalto-60, definiu-se um conjunto de testes retirados dos protocolos TEC DOC 1151 Aspectos Físicos da Garantia de Qualidade em Radioterapia, Protocolo de Controle de Qualidade (TEC DOC 1151, 2000), o Technical Reports Series Number 430 (TRS 430) (IAEA, 2004), o TRS 398 Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water (TRS 398, 2004). Avaliamos a dose na profundidade de interesse dos simuladores de acrílico utilizados para controle de qualidade em tomografia computadorizada, realizamos testes de software e hardware bem como a entrada e saída de dados, testes de contorno, percentual de dose profunda e perfil de campo. Verificou-se que os resultados foram satisfatórios, apenas o teste de perfil de campo não satisfez as expectativas devido a limitações no sistema.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.ufsm.br:1/9241 |
Date | 29 May 2014 |
Creators | Schmidt, Giovana Tamiozzo |
Contributors | Piquini, Paulo Cesar, Oliveira, Gilberto Orengo de, Dorneles, Lucio Strazzabosco |
Publisher | Universidade Federal de Santa Maria, Programa de Pós-Graduação em Física, UFSM, BR, Física |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Repositório Institucional da UFSM, instname:Universidade Federal de Santa Maria, instacron:UFSM |
Rights | info:eu-repo/semantics/openAccess |
Relation | 100500000006, 400, 500, 300, 500, 500, fd6922d3-ec6f-44ef-947e-a60a90ff9691, 4f0858c8-2b2a-4ea7-abfb-e886415c5358, e724651c-44d0-4052-bb71-25c5aaad1bb1, 21612f60-7a0c-4741-b9e2-9a86b3c91a3c |
Page generated in 0.0019 seconds