Return to search

Branddimensionering av betongpelare enligtEurokod : Jämförelsestudie mellan Zonmetoden ochTabellmetoden

One of the biggest challenges of our time is the climate change. With a rapid change infocus for a more substantiality in structural design. This means that we need to reducethis sector emissions and we have with this paper shown how one way of this ispossible. And that is to reduce the amount of concrete in the structure withoutcompromising security or the structural integrity.This report shows that if constructors wants, there is ways to make this happen alreadytoday without making changes in the law or regulations. If building constructers use thezone method, they can reduce the use of concrete with more than 36% concrete pillarshowed by this report.We have trough this paper discovered the main obstacle with calculations and use of thezone method is the temperature and unclarity with the method in the Eurocodes. Wewant to highlight the opportunity’s this method gives constructors to make moreenvironmental choices.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:hh-43113
Date January 2020
CreatorsHändig, Andreas, Fridlund, Johannes
Source SetsDiVA Archive at Upsalla University
LanguageSwedish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0021 seconds