Return to search

Comparação do uso da tirosinase purificada e na forma de extrato bruto enzimático em biossensores amperométricos para a detecção de catecol / Comparison of tyrosinase biosensors from the purified enzyme and in the crude extract form for catechol detection.

Este trabalho tem como principal objetivo comparar as respostas de biossensores amperomé-tricos preparados a partir do uso de uma enzima, a tirosinase (polifenoloxidase, PFO), quando nas formas purificada e adquirida comercialmente e de extrato bruto enzimático do fruto do abacate (Persea Americana). As soluções de PFO apresentaram valores de atividades enzimá-ticas de 479 unidades de enzimas ativas por mililitro (UA mL-1) (purificada) e 259 UA mL-1 (extrato bruto). A enzima nas duas formas (pura e como extrato bruto) foi imobilizada quimi-camente em substratos de Au modificados com monocamadas automontadas (self-assembly monolayers, SAMs) de ácido mercaptopropiônico (MPA) pela técnica de impressão por mi-crocontato (CP). Os biossensores foram preparados sobre substratos de Au modificados por CP com um molde elastomérico de polidimetilsiloxano (PDMS), cujas trilhas paralelas de 100 m foram produzidas pela cura polimérica sobre um molde mestre de GaAs. A réplica de PDMS se mostrou fiel em relação ao molde mestre nos picos e vales, mas apresentou defeitos na borda dos moldes. Com o objetivo de otimizar o funcionamento dos biossensores, eles fo-ram caracterizados pelas técnicas de voltametria cíclica e cronoamperometria com um sistema de análise de injeção em fluxo (FIA) em meio de catecol a diferentes concentrações. Os po-tenciais de oxidação do catecol nos eletrodos de Au modificados foram observados em 418 e 365 mV, em pHs ótimos de funcionamento de 7,0 e 7,2, e com limites de detecção de 6,65 nmol L-1 e 4,65 nmol L-1 para os biossensores com a enzima purificada e com o extrato bruto, respectivamente. A saturação dos sensores teve início a uma concentração de catecol de 0,02 mol L-1. Com estes resultados, mostramos que é possível o preparo de biosensores com um baixo custo, eficientes e miniaturizadas a partir do uso da PFO na forma extrato bruto do fruto do abacate para a detecção de compostos fenólicos, tal como catecol, abrindo assim a possibi-lidade de uso destes biossensores na análise e no monitoramento de pesticidas presentes no solo e na água. / The main objective of this master thesis is to compare the performance of amperometric biosensors prepared using the purified tirosinase (PPO) enzyme, (commercially acquired) and the PPO present in the enzymatic crude extract from the avocado fruit (Persea Americana). The PPO solutions had 479 units of active enzyme per milliliter (UA mL-1) (purified) and 259 UA mL-1 (crude extract). Both forms of the enzyme (purified and crude extract) were chemically immobilized on gold substrates patterned with 3-mercaptopropionic acid (MPA) self assembled monolayers (SAMs), using the microcontact printing (CP) technique. The biosensors were prepared on gold subtracts patterned using CP with a polydimethylsiloxane (PDMS) elastomeric mold, that was shaped in the form as tracks using a gallium arsenate master mold. The PDMS mold was quite similar to the master mold in its peaks and valleys, but defects were found on the edges. In order to optimize the parameters of the biosensors , they were characterized using cyclic voltammetry and chronoamperometry techniques in a FIA system by cathecol injections at different concentrations. The oxidation potentials for the cathecol analysis using the patterned biosensors were observed at 418 and 365 mV, the optimum pH were 7,0 and 7,0, with detection limits of 6,65 nmol L-1 and 4,65 nmol L-1 for the purified enzyme and crude extract biosensors, respectively. The biosensors saturation point started at 0,02 mol L-1 of cathecol concentration. With this results, we demonstrate that it is possible to use miniaturized, efficient, low cost biosensors based on tyrosine from the avocado´s fruit crude extract to detect phenolic compounds, as the cathecol. This expands the possibility of using this biosensors in the analysis and monitoring pesticides in water and soil.

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-30112009-160515
Date16 February 2009
CreatorsRodrigo Lins Pagliai
ContributorsDebora Goncalves, Ronaldo Censi Faria, Marcia Nitschke
PublisherUniversidade de São Paulo, Ciência e Engenharia de Materiais, USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0038 seconds