Return to search

Determinação rápida da concentração de biodiesel em diesel (BXX) através de espectrofluorimetria e análise covariante de dados

Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2016-09-05T18:41:37Z
No. of bitstreams: 1
Dissertação_Humbervania Reis Gonçalves da Silva_2012.pdf: 1948968 bytes, checksum: 1e2bef735b027e934bccadc6da99dff4 (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2016-09-06T11:31:39Z (GMT) No. of bitstreams: 1
Dissertação_Humbervania Reis Gonçalves da Silva_2012.pdf: 1948968 bytes, checksum: 1e2bef735b027e934bccadc6da99dff4 (MD5) / Made available in DSpace on 2016-09-06T11:31:39Z (GMT). No. of bitstreams: 1
Dissertação_Humbervania Reis Gonçalves da Silva_2012.pdf: 1948968 bytes, checksum: 1e2bef735b027e934bccadc6da99dff4 (MD5) / CAPES / A monitoração da qualidade dos combustíveis é importante, não apenas em
decorrência do desempenho dos veículos, mas também devido ao impacto
ambiental das emissões de poluentes. Combustíveis adulterados resultam em
aquecimento e aceleração do motor, além de aumentarem o consumo de
combustível, a emissão de material particulado e de gases de exaustão. No Brasil,
na década de 90 houve várias experiências de produção e uso de biodiesel a partir
de diversas matérias-primas de origem vegetal ou animal, assim como de óleo
residual. No entanto, apenas com a Portaria Nº 310 de 27/12/2001, a ANP
estabeleceu as especificações para comercialização de óleo diesel e sua mistura
com 2% de biodiesel e definiu obrigações dos agentes econômicos sobre o controle
de qualidade do biocombustível. O trabalho visa simplificar os testes utilizados para
caracterizar as misturas de biodiesel e diesel, de B00 (0%v/v de biodiesel no diesel)
até B100 (100%v/v de biodiesel puro). Foi utilizada a técnica de espectrofluorimetria
total 3D em combinação com Análise do Componente Principal (PCA) para
identificar adulteração de bicombustível, pela mudança dos valores de
concentrações de biodiesel em diesel. Os espectros de emissão fluorescente das
amostras foram realizadas em um espectrofluorímetro, onde a emissão foi detectada
de 230 a 800 nm em intervalos de 0,5 nm enquanto as moléculas presentes na
amostra sofriam excitação em comprimentos de onda fixos na faixa de 200 a 775
nm. Outros espectros de emissão fluorescente das amostras foram obtidos
excitando-se as amostras com LED de 365 nm e capturando-se a emissão na faixa
de 385 a 1000 nm com incremento de 1 nm. Foram preparadas 76 amostras, todas
foram analisadas através da Espectroscopia de Fluorescência Total associada à
PCA e foi possível identificar adulterações de diesel em decorrência do excesso de
biodiesel, ultrapassando os valores permitidos por lei. / Monitoring of fuel quality is important, not only because of the performance of
vehicles, but due to the environmental impact of emissions of pollutants. Adulterated
fuels result in heating and acceleration of the motor, besides increasing the fuel
consumption, emissions and particulate matter exhaust gas . In Brazil, in the 90s
there were several experiences of production and use of biodiesel from various raw
materials of vegetable or animal origin, as well as residual oil. However, only with
Ordinance
No.
310,
27/12/2001,
ANP
established
specifications
for
commercialization of diesel and its mixture with 2% biodiesel and defined obligations
of economic agents about the quality control of the biofuel. The work aims to simplify
the tests used to characterize mixtures of biodiesel and diesel, B00 (0% v / v
biodiesel in C) to B100 (100% v / v of pure biodiesel). We used the technique of
spectrofluorimetry full 3D in combination with PCA to identify adulteration of biofuel,
by changing the values of concentrations of biodiesel in diesel. The fluorescence
emission spectra of the samples were performed in a spectrofluorometer where the
emission was detected at 230-800 nm in steps of 0.5 nm while the sample suffered
excitation in wavelengths fixed at 200-775 nm. Other fluorescent emission spectra of
the samples were obtained by exciting the sample with LED of 365 nm and capturing
the emission in the range 385 to 1000 nm with an increment of 1 nm. Have been
prepared 76 samples, all were analyzed by Fluorescence Spectroscopy Total
associated with PCA and were able to identify adulteration of diesel fuel due to the
excess biodiesel, exceeding the values allowed by law.

Identiferoai:union.ndltd.org:IBICT/oai:192.168.11:11:ri/20270
Date24 September 2012
CreatorsSilva, Humbervânia Reis Gonçalves da
ContributorsQuintella, Cristina Maria Assis Lopes Tavares da Mata Hermida, Pantoja, Martha, Meira, Marilena, Vieira, Ângelo Marcos
PublisherInstituto de Química, Programa de Pós Graduação em Química, IQ, brasil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFBA, instname:Universidade Federal da Bahia, instacron:UFBA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0017 seconds