Return to search

Avaliação por tomografia computadorizada do acometimento pulmonar no pós-parto imediato / An analysis of pulmonary distress after immediate childbirth through the use of computerized tomography

Durante a gravidez o sistema respiratório sofre modificações. Além da elevação do diafragma, provavelmente secundária ao aumento do volume uterino, estudos indicaram que, com a progressão da gestação algumas mudanças em volumes e capacidades pulmonares ocorrem como redução na capacidade residual funcional, volume de reserva expiratório, volume corrente e da capacidade inspiratória. Uma das hipóteses para explicar esses achados é que a elevação do diafragma pode causar colapso pulmonar, que pode ser pior em mulheres que realizaram parto cesariana (PC), quando comparadas as que tiveram parto vaginal (PV). Este estudo avaliou 20 mulheres, 2 a 5 horas após o parto em um Hospital Universitário. Após a obtenção do consentimento livre e esclarecido, 20 mulheres saudáveis, não-fumantes, onde 10 mulheres haviam realizado PV e 10 haviam realizado PC, após o parto foram submetidos à tomografia computadorizada torácica. A imagem foi analisada por um sistema de software (Osíris). A média de atenuação de cada fatia foi expresso em unidades Hounsfield (UH) e medido o percentual da área de colapso pulmonar (em g%). No grupo PV a média foi de -841,90 UH e 3,95 g%, enquanto que no grupo PC a média foi de -765,95 UH e 14,1g%. Estes resultados sugerem que as mulheres submetidas ao PC têm maior área de colapso pulmonar comparado com mulheres submetidas ao PV / During pregnancy the respiratory system undergoes several modifications. Besides the elevation of diaphragm, probably secondary to the increase in uterine volume, studies indicated that with the progression of the gestation some changes in pulmonary volumes and capacities occur, as a reduction in Functional Residual Capacity, Expiratory Reserve Volume, Tidal Volume and Inspiratory Capacity. One of the hypotheses to explain these findings is that the elevation of diaphragm may cause pulmonary collapse, which may be worse in women who underwent a cesarean section when compared to those who had vaginal delivery. This paper evaluates 20 women, 2 to 5 hours after delivery in a University Hospital. After getting informed consent, 20 healthy non-smoking women, 10 who underwent vaginal delivery (VD) and 10 who underwent a cesarean section (CS), were submitted to a chest computed tomography. The images of two different basal lung levels were analyzed by means of a software system (Osiris). The mean attenuation value of each slice in Hounsfield Units (UH) were measured and the percentage area of collapsed lung (in g%) was calculated. In the VD group the mean attenuation was - 841.90 UH and the collapsed area was 3.95 g%, while in the CS group the mean attenuation was -765.95 UH and the collapsed area was 14.1 g%. These results suggested that women who underwent a cesarean section have more collapse at basal lung levels than women who had a vaginal delivery

Identiferoai:union.ndltd.org:IBICT/oai:teses.usp.br:tde-03062009-091219
Date24 March 2009
CreatorsMariana Natal de Castro Meira
ContributorsJoaquim Edson Vieira, Fabio Ely Martins Benseñor, Arnaldo Lichtenstein
PublisherUniversidade de São Paulo, Ciências (Fisiopatologia Experimental), USP, BR
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Biblioteca Digital de Teses e Dissertações da USP, instname:Universidade de São Paulo, instacron:USP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds