• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • Tagged with
  • 31
  • 27
  • 22
  • 16
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aspiração nasotraqueal profunda precedida de manobras fisioterápicas no tratamento de atelectasia de reabsorção por rolha de secreção em recém-nascidos

Rocha, Maria da Graça Coutinho January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saude. Programa de Pós-graduação em Ciências Médicas / Made available in DSpace on 2012-10-22T10:19:03Z (GMT). No. of bitstreams: 1 243262.pdf: 849434 bytes, checksum: 352594f34eda9b144b7349af9abc58d0 (MD5) / O uso da broncofibroscopia com realização de lavado broncoalveolar, escovado brônquico e biópsia pulmonar transbrônquica destaca-se como método útil no diagnóstico das afecções pulmonares em pacientes infectados com o vírus da imunodeficiência humana. Contudo, os dados referentes à acurácia dessas técnicas são confiantes A fim de estimar a sensibilidade dessas técnicas no diagnóstico de afecções pulmonares em pacientes infectados com o HIV em nosso meio, foram estudados consecutivamente 71 pacientes, a maioria com sintomatologia respiratória, superior a 15 dias (58%), e alterações radiográficas do tipo intersticial (62%). A sensibilidade foi calculada tomando-se como referência um padrão-ouro construído, que consistiu nos resultados combinados das três técnicas utilizadas. As sensibilidades do lavado broncoalveolar, da biópsia pulmonar transbrônquica e do escovado brônquico foram de 86%, 43% e 5%, respectivamente. A associação de lavado broncoalveolar e biópsia pulmonar transbrônquica aumentou a sensibilidade para 100%. O índice de complicações foi de 3%. Estes resultados sugerem que, nessa população: (I) a broncofibroscopia com realização de lavado broncoalveolar, escovado brônquico e biópsia pulmonar transbrônquica é procedimento seguro e com bom rendimento diagnóstico; (2) o lavado broncoalveolar foi a técnica isolada com maior rendimento diagnóstico, sendo que o lavado broncoalveolar e a biópsia pulmonar transbrônquica foram técnicas complementares; (3) o uso do escovado brônquico, na sequência utilizada neste protocolo, não aumentou o rendimento diagnóstico das técnicas realizadas. Abstract : Bronchoscopy with bronchoalveolar lavage, bronchial brush and transbronchial biopsy are useful methods for the dlagnosis of pulmonary diseases in patients infected with the human immunodeficiency vírus (HIV). However, data on accuracy of these techniques are conflicting. In order to estimate the sensitivity of the bronchoalveolar lavage, bronchial brush and transbronchial biopsy in pulmonary disease diagnosis in patients infected with HIV, we studied 71 consecutive patients, most of them with respiratory symptoms up to 15 days (58%) and radiologia signs of interstitial infiltrates (62%). The sensitivity was calculated taking as referende a constructed gold-standard, represented by the sum of all three techniques combined. Sensitivities for bronchoalveolar lavage, transbronchial biopsy and bronchial brush were 86%, 43% and 5%, respectively. The association of bronchoalveolar lavage and transbronchial biopsy reached the sensltlvlty to 100%, reflecting how the gold-standard was constructed. The complication rate of the procedures was 3%. These results suggest that, in this population: (1) bronchoscopy with bronchoalveolar lavage, bronchial brush and transbronchial biopsy are secure procedures with good diagnosis performance; (2) bronchoalveolar lavage alone has reached the highest sensitivity, whereas both bronchoalveolar lavage and transbronchial biopsy can be considered complementary techniques; (3) the association of bronchoalveolar lavage and transbronchial biopsy performed better than bronchoalveolar lavage alone; and (4) the use of bronchial brush, in the sequence used in this protocol, did not have any influence on the diagnosis performance.
2

Diferentes frações inspiradas de oxigênio associado ao ar comprimido ou óxido nitroso, em leitões anestesiados com propofol e mantidos sob ventilação controlada e peep / Different inspired fractions of oxygen associated with compressed air or nitrosous oxide, in piglets anesthetized with propofol and kept with controlled ventilation and peep

Biteli, Eliselle Gouveia de Faria [UNESP] 18 December 2017 (has links)
Submitted by Eliselle Gouveia de Faria null (lellyfaria@hotmail.com) on 2018-01-29T18:07:11Z No. of bitstreams: 1 Tese_Eliselle_Gouveia_de_Faria_Biteli.pdf: 4027081 bytes, checksum: b84e13a67ab48c05a1dd9f39c2d8be6d (MD5) / Approved for entry into archive by Karina Gimenes Fernandes null (karinagi@fcav.unesp.br) on 2018-01-30T12:17:05Z (GMT) No. of bitstreams: 1 biteli_egf_dr_jabo.pdf: 4011438 bytes, checksum: 5575bda6c7245c490c94543e9cbca487 (MD5) / Made available in DSpace on 2018-01-30T12:17:05Z (GMT). No. of bitstreams: 1 biteli_egf_dr_jabo.pdf: 4011438 bytes, checksum: 5575bda6c7245c490c94543e9cbca487 (MD5) Previous issue date: 2017-12-18 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Compararam-se os efeitos de diferentes frações inspiradas de oxigênio (FiO2) associado ao óxido nitroso (N2O) ou ao ar comprimido sobre a hematose, parâmetros cardiorrespiratórios, intracranianos e o índice biespectral (BIS), em leitões mantidos em ventilação espontânea ou controlada a pressão, associada ou não à PEEP (5 cmH2O). Foram utilizados 48 leitões, distribuídos em 6 grupos, submetidos à 10, 30 e 50% de ar comprimido (GA10, GA30 e GA50) ou N2O (GN10, GN30 e GN50), associadas às FiO2 de 0,9, 0,7 e 0,5, respectivamente. O GA30 mostrou maior proximidade do intervalo fisiológico da pressão parcial de oxigênio no sangue arterial. A PEEP não foi eficaz na pressão parcial de dióxido de carbono no sangue arterial, independente da FiO2, quando se utilizou o N2O. O pH, déficit base e bicarbonato no sangue arterial foram influenciados pela FiO2 e N2O. As alterações do volume corrente e volume minuto parecem correlacionadas à introdução da ventilação mecânica (VM) e PEEP. Na diferença alvéolo-arterial de oxigênio, a PEEP influenciou negativamente o GA30 e GN30 e não foi adequada para manutenção do shunt pulmonar. Já a pressão média da artéria pulmonar e pressão média capilar pulmonar apresentaram acréscimos após introdução da PEEP. A associação da PEEP com N2O (50%) ou ar comprimido (50%) parece ser a receita para desempenho inferior da variação de pressão de pulso. Para a pressão intracraniana, apenas o GN30 apresentou valor menor ao se instituir a VM quando comparado com o momento em que houve início do auxílio com a PEEP. Concluiu-se que, nenhuma concentração de N2O é segura para a manutenção dos parâmetros hemogasométricos. A VM e a PEEP não são eficientes para manutenção das variáveis respiratórias. A PEEP promove piora no desempenho de parâmetros cardiovasculares e intracranianos. Maiores taxas de oferta de N2O (50%) reduzem o BIS em suínos. / The effects of different fractions of inspired oxygen (FiO2) associated with compressed air or nitrous oxide (N2O) on lung oxygenation, cardiorespiratory parameters, intracranial parameters and the bispectral index (BIS) were compared in piglets maintained under spontaneous or controlled ventilation, with or without PEEP (5 cmH2O). Forty-eight piglets, distributed in six groups, were submitted to 10, 30 and 50% of compressed air (GA10, GA30 and GA50) or N2O (GN10, GN30 and GN50), associated with FiO2 of 0.9, 0.7 and 0.5, respectively. GA30 showed greater proximity to the physiological range of partial oxygen pressure in the arterial blood. When N2O was used, PEEP was ineffective in maintaining partial carbon dioxide pressure in the arterial blood, independent of FiO2. Arterial blood pH, base deficit and bicarbonate were influenced by FiO2 and N2O. Changes in tidal and minute volumes seem to correlate with the introduction of mechanical ventilation (MV) and PEEP. The difference in alveolar-arterial oxygen under PEEP negatively influenced GA30 and GN30 and was inadequate for pulmonary shunt maintenance. Mean pulmonary artery pressure and mean capillary pulmonary pressure increased following the initiation of PEEP. The association of PEEP with N2O (50%) or compressed air (50%) seems to result in lower performance of pulse pressure variation. Regarding intracranial pressure, only GN30 presented a lower value when MV was established compared with the time point when PEEP was initiated. In conclusion, no concentration of N2O is safe for maintaining blood gas parameters. MV and PEEP are inefficient in the maintenance of respiratory variables. PEEP promotes deterioration in the performance of cardiovascular and intracranial parameters. Higher N2O supply rates (50%) reduce BIS in pigs. / 2013/25655-0
3

Efetividade da espirometria de incentivo na prevenção de complicações pulmonares após cirurgia de revascularização da artéria coronária: revisão sistemática e metanálise / Efectiveness of incentive spirometry for preventing pulmonary complications following coronary artery bypass grafts: systemic review and meta-analyse

Freitas, Eliane Regina Ferreira Sernache de [UNIFESP] January 2006 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:07:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2006 / INTRODUÇÃO: A espirometria de incentivo tem permanecido uma técnica de fisioterapia cardiorrespiratória amplamente usada para profilaxia e tratamento de complicações respiratórias em pacientes pós-cirúrgicos. OBJETIVOS: Avaliar a efetividade da espirometria de incentivo na prevenção de complicações pulmonares pós-operatória em adultos submetidos à cirurgia de revascularização da artéria coronária. MÉTODOS: O tipo de estudo utilizado foi a revisão sistemática de ensaios clínicos aleatórios. Foram utilizadas oito bases de dados (Medline, Embase, Cinahl, Lilacs, CENTRAL - Cochrane Field Rehabilitation and related therapies, PeDro, AMED e DARE) com suas respectivas estratégias de busca, referências de artigos e revistas especializadas, sem restrição de idiomas na sua identificação. Foram incluídos estudos sobre o uso da espirometria de incentivo em pacientes submetidos à cirurgia de revascularização da artéria coronária. Os desfechos clínicos analisados foram atelectasia, pneumonia, capacidade vital, volume expiratório forçado no 1° segundo, pressão parcial de oxigênio arterial pela fração inspirada de oxigênio e tempo de permanência hospitalar. A qualidade dos métodos foi avaliada segundo a ocultação da alocação, conforme a metodologia da Colaboração Cochrane, e de acordo com a lista Delphi, por dois avaliadores independentes. Os dados dos estudos foram extraídos por meio de uma ficha padronizada. Para avaliar a concordância dos resultados da qualidade dos estudos, foi usado o teste Kappa. Para as variáveis contínuas, foi calculada a diferença da média ponderada (efeito fixo), e para as variáveis categóricas foi calculada a razão de chances de ocorrência dos eventos (Odds Ratio), ambos com intervalo de confiança de 95 por cento. RESULTADOS: Sete ensaios clínicos preencheram os critérios de inclusão, porém somente quatro estudos foram incluídos para metanálise, num total de 443 participantes (184 espirometria de incentivo; 259 controle). Nenhum dos estudos incluídos descreveu de forma adequada a ocultação de alocação. Não encontramos nenhuma evidência de diferença estatística significante de efeito estimado de risco (OR) a favor da espirometria de incentivo na prevenção de complicações pulmonares, quando comparada às outras técnicas de fisioterapia cardiorrespiratória ou ao grupo que não foi submetido à um programa sistematizado de fisioterapia. CONCLUSÃO: Evidências existentes não apóiam o uso da espirometria de incentivo para prevenir complicações pulmonares nos pacientes submetidos à cirurgia de revascularização da artéria coronária / Introduction: The Incentive spirometry remains the most widely used cardiorespiratory physiotherapy technique for the prevention and treatment of respiratory complications in post-operative patients. Objectives: To evaluate the effectiveness of incentive spirometry in the prevention of postoperative pulmonary complications in adults who underwent coronary artery bypass graft. Methods: A systematic review of random clinical trials was carried out, using information from nine data bases (Medline, Embase, Cinahl, Lilacs, CENTRAL, Cochrane Field Rehabilitation and related therapies, PeDro, AMED, and DARE) with their respective search strategies, as well as articles and specialized magazine references, with no restriction to language. Studies on the use of incentive spirometry in patients who underwent coronary artery bypass graft were included. Clinical outcomes were atelectasis, pneumonia, vital capacity, forced expiratory volume in 1 second, partial pressure of arterial oxygen per oxygen inspired fraction and the durations of total hospital stay. Method quality was assessed according of concealment of allocation, in agreement with the Cochrane Collaboration Method and the Delphi List, by two independent evaluators. Data were collected by a standardized record file. The Kappa Test was used to evaluate agreement among quality studies results. The difference between average means (fixed effect) was calculated for the continuous variables, and the Odds Ratio was used for the categorical variables, both with a reliability interval of 95%. Results: Seven clinical trials met the eligibility criteria, however only four studies were included for meta-analysed. In total 443 patients were enrolled (184 treatment group, 259 control group). None of the included studies described adequately the concealment allocation procedure. We did not find any evidence of statistical difference accompanied of estimated effect of risk (OR) and confidence interval of 95% in favor of incentive espirometry in the prevention of pulmonary complications when compared to other cardiorespiratory physical therapy techniques or the physiotherapy absence. Conclusion: The evidences do not support the use of incentive espirometry to prevent pulmonary complications in the patients undergoing coronary artery bypass graft. / BV UNIFESP: Teses e dissertações
4

Efeitos da manobra de compressão e descompressão torácica em pacientes submetido à ventilação mecânica / Effects of manual chest compression and decompression in patients receiving mechanical ventilation

Via, Fabiana Della, 1983- 19 August 2018 (has links)
Orientador: Desanka Dragosavac / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-19T13:03:30Z (GMT). No. of bitstreams: 1 DellaVia_Fabiana_M.pdf: 1891187 bytes, checksum: 4def93d7b8f4cf136b7e8e9214f38a3b (MD5) Previous issue date: 2011 / Resumo: INTRODUÇÃO: Os pacientes internados em Unidades de Terapia Intensiva (UTI) que necessitam de ventilação mecânica (VM) estão mais susceptíveis ao desenvolvimento de complicações respiratórias, principalmente a atelectasia e a broncopneumonia. Para que haja reversão ou mesmo prevenção dessas áreas atelectasiadas, são utilizadas técnicas fisioterapêuticas de expansão pulmonar, dentre elas destaca-se a manobra de compressão e descompressão torácica (MCDT). OBJETIVO: Avaliar as alterações respiratórias e hemodinâmicas após aplicação da MCDT nos pacientes em uso de VM. MÉTODO: Tratou-se de um estudo prospectivo, intervencionista, onde foram incluídos 65 pacientes em VM há mais de 24 horas. Todos os pacientes receberam manobras de higiene brônquica e após 30 minutos foram aplicadas 20 repetições da manobra de compressão e descompressão torácica em dez respirações consecutivas no hemitórax direito e depois dez no hemitórax esquerdo. Os dados foram coletados antes, imediatamente após e após um, cinco, dez, 15, 20, 25, 30, 35 e 40 minutos da aplicação da MCDT. Para análise estatística foram utilizados testes: Shapiro Wilks, Anova, Wilcoxon, T - Student, com nível de significância adotado de 5%. RESULTADOS: Foi observado aumento estatisticamente significante do volume corrente inspiratório (pré: 458,2ml ± 132,1; pós 1 min: 557,3 ± 139,1; pós 40 min: 574,4 ± 151), volume minuto corrente (pré: 7,0L/min ± 2,7; pós 1 min: 8,7 ± 3,3; pós 40 min: 8,8 ± 3,8) e oximetria de pulso (pré: 97,4% ± 2,2; pós 1 min: 97,9 ± 1,8; pós 40 min: 98,2 ± 1,6). Ocorreu redução no PetCO2 expirado (pré: 35,1mmHg ± 9,0; pós 1 min: 31,5 ± 8,2; pós 40 min: 31,5 ± 8,2). Não houve alteração significante da freqüência cardíaca (pré: 94,5bpm ± 20,5; pós 1 min: 94,7 ± 20,5 e pós 40 min: 94,9 ± 20,2) e pressão arterial média (pré: 91,2mmHg ± 19,1; pós 1 min: 89,5 ± 17,7 e pós 40 min: 89,0 ± 16,8). CONCLUSÃO: A MCDT possibilita a otimização dos volumes pulmonares e oximetria de pulso e redução do PetCO2 sem promover alterações hemodinâmicas nos pacientes submetidos a ventilação mecânica / Abstract: INTRODUCTION: Patients in Intensive Care Units (ICU) requiring mechanical ventilation (MV) are more likely to develop respiratory complications, especially atelectasis and bronchopneumonia. Reversing or even prevention of these areas of atelectasis, physiotherapeutic techniques are used for lung expansion, chief among which is the maneuver of chest compression and decompression (MCCD). OBJECTIVE: To evaluate the respiratory and hemodynamic changes after application of MCCD in patients submitted to mechanical ventilation (MV). METHOD: It's a prospective and interventionist study of 65 patients submitted to MV after 24 hours. All patients received a bronchial hygiene and after 30 minutes, they were submitted to 20 repetitions of the MCCD during ten consecutive respiratory cycles on right hemithorax and than ten in left hemithorax. The data were collected before, after immediately and after one, five, ten, 15, 20, 25, 30, 35 and 40 minutes following application of the MCCD. RESULTS: There were an significant improvement in the following parameters after MCCD during all phases of data collection until 40 minutes: inspiratory tidal volume (baseline: 458,2ml ± 132,1; post 1 min: 557,3 ± 139,1; post 40 min: 574,4 ± 151 ), minute volume (baseline: 7,0L/min ± 2,7; post 1 min: 8,7 ± 3,3; post 40 min: 8,8 ± 3,8), and pulse oximetry (baseline: 97,4% ± 22; post 1 min: 97,9 ± 1,8; post 40 min: 98,2 ± 1,6) . A reduction occurred in expiratory PetCO2 (baseline: 35,1mmHg ± 9,0; post 1 min: 31,5 ± 8,2; post 40 min: 31,5 ± 8,29). No alteration occurred in heart rate (baseline: 94,5bpm ± 20,5; post 1 min: 94,7 ± 20,5; post 40 min: 94,92 ± 20,20) and mean arterial pressure (baseline: 91,2mmHg ± 19,1; post 1 min: 89,5 ± 17,7; post 40 min: 89 ± 16,8). CONCLUSION: There were positive effects on the MCCD maneuver with increased lung volumes, pulse oximetry and reduction in expiratory PetCO2, without hemodynamic changes in patients submitted to mechanical ventilation / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências
5

Incidência, fatores de risco e consequências da extubação acidental em recém-nascidos prematuros com menos de 1.500 gramas, internados na Unidade de Terapia Intensiva Neonatal do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto - USP / Incidence, risk factors and consequences of accidental extubation in premature infants less than 1,500 grams admitted to the Neonatal Intensive Care Unit of the Hospital das Clínicas of the Medical School of Ribeirão Preto - USP

Pirone, Ana Carolina Eleutério 22 February 2019 (has links)
Os prematuros frequentemente necessitam de ajuda para iniciar a respiração, pois líquido amniótico residual e deficiência de surfactante podem impedir o estabelecimento da CRF. A necessidade de intubação e do uso de ventilação com pressão positiva está relacionada à chamada lesão pulmonar induzida pela ventilação. A intubação endotraqueal é uma ocorrência comum na unidade de terapia intensiva neonatal. A extubação acidental (EA) ou o deslocamento acidental do tubo endotraqueal é um evento inseguro e adverso. Um estudo norteamericano relatou que a EA é o quarto evento adverso mais comum na UTIN. Isso coloca o neonato em risco de morbidade significativa. As hipóteses iniciais para este estudo considerando as características locais do serviço, são que a taxa de extubação acidental deste serviço seria superior ou igual à encontrada na literatura e que as consequências da perda de volume pulmonar causada pela EA geraria uma necessidade de aumento de parâmetros ventilatórios, expondo esses pacientes a um maior risco de desenvolvimento de lesão pulmonar induzida pela ventilação mecânica. O presente estudo teve como objetivo estabelecer a densidade de extubação acidental para cada 100 pacientes-dia e os fatores de risco e as consequências associadas à extubação acidental em uma unidade de terapia intensiva neonatal. A coleta de dados ocorreu o período de fevereiro a dezembro de 2016. Foram elegíveis todos os recém-nascidos intubados com necessidade de ventilação mecânica invasiva e selecionados, para o estudo, os recém-nascidos em assistência ventilatória há pelo menos 12 horas. Nos 10 meses e meio de estudo (318 dias), observou-se uma média de 9,04 pacientes intubados por dia, sendo analisados 2875 pacientes-dia com via aérea artificial. Nos 318 dias de observação ocorreram 45 extubações acidentais, com taxa de EA de 1,57 para cada 100 dias intubação. Os recém-nascidos tinham em média 26,55±35,35 dias de vida na EA, mínimo de 3 dias e máximo de 182 dias. Na amostra estudada, todos os recém-nascidos necessitaram de reintubação após o evento de EA. As características clínicas foram semelhantes nos dois grupos. Assim, os dados apresentados evidenciam que os grupos estudados se apresentaram bastante homogêneos. Foram associados como fatores de risco para EA a utilização de material inadequado para a fixação da cânula orotraqueal (esparadrapo), a carência de pessoal para os cuidados diários (mais de 2 pacientes por funcionário), e mostrou-se ainda a grande importância dos alarmes de saturação sanguínea já que foram responsáveis por 60% diagnóstico da ocorrência do evento. A EA acarretou piora das condições respiratórias com necessidade de aumento do suporte ventilatório ( maior necessidade de oxigênio, pressão inspiratória e PEEP) e recuperação lenta às condições pré- acidente em média 5,7 dias. Concomitante com o aumento da necessidade de suporte respiratório houve maior ocorrência de hiperóxia após o acidente, levantando o temor de efeitos deletérios sinérgicos sobre o pulmão já anteriormente debilitado dos prematuros. É necessária a conscientização da administração e das equipes de profissionais da saúde das UTINs unidades, da enorme importância de se prevenir e diagnosticar precocemente a extubação acidental. / Premature infants often require help in initiating breathing, since residual amniotic fluid and surfactant deficiency may prevent the establishment of functional residual capacity. The need for intubation and the use of positive pressure ventilation is related with ventilator-induced lung injury. Endotracheal intubation is a common occurrence in the neonatal intensive care unit. Accidental extubation (AE) or accidental displacement of the endotracheal tube is an unsafe and adverse event. An American study has reported that EA is the fourth most common adverse event in the NICU. This puts the neonate at risk of significant morbidity. The initial hypotheses for this study considering the local characteristics of the service are that the rate of accidental extubation of this service would be higher than or equal to that found in the literature and that the consequences of loss of lung volume caused by the AE would generate a need for increased ventilatory parameters , exposing these patients to a higher risk of lung injury induced by mechanical ventilation. The present study aimed to establish the accidental extubation density for each 100 patients per day and the risk factors and consequences associated with accidental extubation in a neonatal intensive care unit. Data were collected from February to December 2016. All intubated newborns requiring invasive mechanical ventilation were eligible and the newborns in ventilatory assistance were selected for at least 12 hours for the study. In the 10 and a half months of study (318 days), an average of 9.04 intubated patients per day was observed, with 2875 day-patients with artificial airway being analyzed. In the 318 days of observation, there were 45 accidental extubations, with an AE rate of 1.57 for every 100 days of intubation. The newborns had a mean of 26.55±35.35 days of life in AE, a minimum of 3 days and a maximum of 182 days. In the studied sample, all newborns required reintubation after the AE event. As constitutional aspects were seem in the two groups. Thus, the presented data evidences that the studied groups are quite homogeneous. Risk factors for the use of materials for the fixation of the orotracheal waist (tape), a shortage of personnel for the longest care, and the greater importance of the alarms were included. of blood saturation that was responsible for 60% of the occurrence of the event. AE is one of the largest public health service companies in the world, inspiratory pressure and PEEP, and average recurring expenses an average of 5.7 days. Concomitant with the increased risk of respiratory accident for most cases following the occurrence of an accident, raising the risk of fire and synergy over the previous exercise already weakened of the premature. Immigration is an awareness of NICU management and staff of health professionals, which is important in preventing and early diagnosis of accidental extubation.
6

Papel da compressão mecânica exercida pelo coração sobre o pulmão na formação de atelectasias após revascularização do miocárdio / Role of the mechanical compression exerted by the heart on the lungs in atelectasis formation after myocardial revascularization

Neves, Flavio Humberto de Sousa 19 July 2012 (has links)
Introdução: A hipoxemia é uma complicação frequente no pós-operatório de cirurgia de revascularização miocárdica (RM) com circulação extracorpórea (CEC), normalmente decorrente da formação de atelectasia pulmonar. O presente estudo visa investigar o papel do coração na perda de aeração dos lobos pulmonares inferiores. Métodos: Dezessete pacientes sem disfunção cardíaca foram submetidos a tomografia computadorizada (TC) pré e pósoperatória em apnéia após expiração normal. A massa cardíaca, a pressão exercida pelas protrusões cardíacas direita e esquerda sobre os segmentos pulmonares subjacentes a elas e a fração de tecido pulmonar atelectasiado dos mesmos segmentos e dos segmentos não subjacentes foram avaliados nos cortes tomográficos 1 cm acima do diafragma. Resultados: A massa cardíaca sofreu um aumento de 32% (117 ± 31g vs. 155 ± 35g; p < 0,001) no pós-operatório, levando a um aumento nas pressões exercidas pelas protrusões cardíacas direita (2,2 ± 0,6 g.cm-2 vs 3,2 ± 1,2 g.cm-2; p < 0,05) e esquerda (2,4 ± 0,7 g.cm-2 vs. 4,2 ± 1,8 g.cm-2; p < 0,001) sobre os segmentos pulmonares subjacentes. A fração média de tecido atelectasiado direita e esquerda abaixo das protrusões aumentou substancialmente no pós-operatório (6,7% para 32,9% e 6,2% para 29%, respectivamente; p < 0,001). Este aumento foi menos pronunciado nas áreas não subjacentes (direito: 0,7% para 10,8%, esquerdo 1,5% para 12,6%; p < 0,001). Conclusão: A pressão exercida pelo coração sobre os pulmões aumentou no período pós-operatório, contribuindo de forma importante para a formação de atelectasias nos segmentos pulmonares subjacentes / Introduction: Atelectasis is a major cause of hypoxemia after onpump coronary artery bypass grafting (CABG). General anesthesia, use of high inspiratory oxygen concentration and cardiopulmonary bypass (CPB) are implicated in the genesis of atelectasis. However, the contribution of pressure exerted by the heart to collapse the underlying lung is unknown. The objective of this study was to evaluate the role of heart-induced pulmonary compression after on-pump CABG. Methods: Seventeen patients without cardiac dysfunction underwent pre and postoperative thoracic computed tomography (CT) in apnea conditions after a normal expiration. The cardiac mass, the pressure exerted on the lungs by the right and left heart segments and the collapsed lung fraction of lower lobe segments below and outside of the heart limits were evaluated in a CT section 1 cm above the diaphragm. Results: Cardiac mass increased by 32% (117 ± 31g vs. 155 ± 35g; p <0.001) postoperatively, leading to an increase in the pressures exerted by right (2.2 ± 0.6 g.cm-2 vs. 3.2 ± 1.2 g.cm-2; p <0.05) and left heart segments (2.4 ± 0.7 g.cm-2 vs. 4.2 ± 1.8 g.cm-2; p <0.001) on the lungs. The median fraction of collapsed right (6.7% to 32.9%; p <0.001) and left (6.2% to 29%; p <0.001) lung parenchyma segments beneath the heart greatly increased postoperatively, while it was less important outside of the heart limits, (right: 0.7% to 10.8; p<0,001 and left: 1.5% to 12.6%; p<0,001). Conclusion: The pressure exerted by the heart on the lungs increased postoperatively, importantly contributing to collapse the subjacent pulmonary segments
7

Avaliação da aeração e edema pulmonar por meio de tomografia computadorizada em pacientes submetidos a revascularização do miocárdio / Evaluation of the aeration and edema pulmonary by means of computed tomography in patients undergoing coronary artery bypass graft

Roseny dos Reis Rodrigues 30 August 2010 (has links)
Introdução: A disfunção respiratória é uma das complicações de maior prevalência no período pós-operatório de pacientes submetidos à cirurgia de revascularização do miocárdio (RM) com circulação extracorpórea (CEC), mesmo na ausência de doença pulmonar prévia1. Por meio de tomografia computadorizada, foram investigadas as alterações pulmonares pósoperatórias e o seu impacto na oxigenação. Métodos: vinte pacientes não hipoxêmicos em programação de cirurgia eletiva de revascularização do miocárdio com CEC foram estudados. Medidas hemodinâmicas, e amostras sanguíneas seriadas foram obtidas antes da cirurgia, após a intubação orotraqueal, após a CEC, na UTI, 12h, 24h e 48h após a cirurgia. Tomografias volumétricas pré e pós-operatórias foram adquiridas em condições de apneia após uma expiração espontânea. Os dados foram analisados usando teste de t Student; o comportamento temporal dos dados hemodinâmicos e outras variáveis fisiológicas foi analisado ao longo do tempo, usando análise de variância de uma via para repetidas medidas, seguido pelo teste de Student-Neumann-Keuls, quando necessário.Resultados: a relação PaO2/FiO2 diminuiu de forma significativa após a indução da anestesia, atingindo o seu nadir após a saída de CEC. Comparando-se com a TC pré-operatória, foi observada uma redução de 31% no volume de gás pulmonar (p<0,001), ao passo que foi observado um aumento do volume de tecido de 19% (p<0,001). A área não aerada dos pulmões aumentou de 253 97 g(p < 0.001), de 3 % a 27 %, após a cirurgia; e a área pobremente aerada pulmonar apresentou aumento de 72 68 g (p < 0.001), de 24 % to 27 %, enquanto a área normalmente aerada pulmonar reduziu de 147 119 g (p < 0.001), que representa 72 % to 46%. Não foram observadas correlações entre a relação PO2/FIO2 ou na fração de shunt nas primeiras 24 horas pós-operatórias Conclusões: A estrutura pulmonar está profundamente modificada após a cirurgia de RM com CEC. Associadas a outros fatores, essas alterações são responsáveis pela ocorrência de hipoxemia resultantes de atelectasias / Introduction: Hypoxemia is a frequent complication after coronary artery bypass graft (CABG) with cardiopulmonary bypass (CPB), usually attributed to atelectasis. Using computed tomography (CT), we investigated pulmonary alterations postoperatively and its impact on oxygenation. Methods: Twenty non-hypoxemic patients with normal cardiac function scheduled to CABG under CPB were studied. Hemodynamic measurements and blood samples were obtained before surgery, after intubation, after CPB, at ICU admission, 12h, 24h and 48h after surgery. Pre and postoperative volumetric thoracic CT scans were acquired in apnea conditions after a spontaneous expiration. Data was analyzed using paired Student t test and two-way repeated measures analysis of variance followed by SNK test when indicated. Results: PaO2/FiO2 ratio was significantly reduced after anesthesia induction, reaching its nadir after CPB and partially ameliorating 12h after surgery. Compared to preoperative CT, there was a postoperative 31 % reduction in pulmonary gas volume (p < 0.001) while tissue volume increased by 19 % (p < 0.001). Non-aerated lung increased by 253 97 g(p < 0.001), from 3 % to 27 %, after surgery and poorly-aerated lung by 72 68 g (p < 0.001), from 24 % to 27 % while normally-aerated lung was reduced by 147 119 g (p < 0.001), from 72 % to 46 %. No correlations were observed between PaO2/FiO2 ratio or shunt fraction at 24 h postoperatively and postoperative lung alterations. Conclusions: Lung structure is profoundly modified after CABG with CPB. Taken together, these multiple alterations occurring in the lungs are responsible for postoperative hypoxemia instead of atelectasis alone
8

Avaliação por tomografia computadorizada do acometimento pulmonar no pós-parto imediato / An analysis of pulmonary distress after immediate childbirth through the use of computerized tomography

Meira, Mariana Natal de Castro 24 March 2009 (has links)
Durante a gravidez o sistema respiratório sofre modificações. Além da elevação do diafragma, provavelmente secundária ao aumento do volume uterino, estudos indicaram que, com a progressão da gestação algumas mudanças em volumes e capacidades pulmonares ocorrem como redução na capacidade residual funcional, volume de reserva expiratório, volume corrente e da capacidade inspiratória. Uma das hipóteses para explicar esses achados é que a elevação do diafragma pode causar colapso pulmonar, que pode ser pior em mulheres que realizaram parto cesariana (PC), quando comparadas as que tiveram parto vaginal (PV). Este estudo avaliou 20 mulheres, 2 a 5 horas após o parto em um Hospital Universitário. Após a obtenção do consentimento livre e esclarecido, 20 mulheres saudáveis, não-fumantes, onde 10 mulheres haviam realizado PV e 10 haviam realizado PC, após o parto foram submetidos à tomografia computadorizada torácica. A imagem foi analisada por um sistema de software (Osíris). A média de atenuação de cada fatia foi expresso em unidades Hounsfield (UH) e medido o percentual da área de colapso pulmonar (em g%). No grupo PV a média foi de -841,90 UH e 3,95 g%, enquanto que no grupo PC a média foi de -765,95 UH e 14,1g%. Estes resultados sugerem que as mulheres submetidas ao PC têm maior área de colapso pulmonar comparado com mulheres submetidas ao PV / During pregnancy the respiratory system undergoes several modifications. Besides the elevation of diaphragm, probably secondary to the increase in uterine volume, studies indicated that with the progression of the gestation some changes in pulmonary volumes and capacities occur, as a reduction in Functional Residual Capacity, Expiratory Reserve Volume, Tidal Volume and Inspiratory Capacity. One of the hypotheses to explain these findings is that the elevation of diaphragm may cause pulmonary collapse, which may be worse in women who underwent a cesarean section when compared to those who had vaginal delivery. This paper evaluates 20 women, 2 to 5 hours after delivery in a University Hospital. After getting informed consent, 20 healthy non-smoking women, 10 who underwent vaginal delivery (VD) and 10 who underwent a cesarean section (CS), were submitted to a chest computed tomography. The images of two different basal lung levels were analyzed by means of a software system (Osiris). The mean attenuation value of each slice in Hounsfield Units (UH) were measured and the percentage area of collapsed lung (in g%) was calculated. In the VD group the mean attenuation was - 841.90 UH and the collapsed area was 3.95 g%, while in the CS group the mean attenuation was -765.95 UH and the collapsed area was 14.1 g%. These results suggested that women who underwent a cesarean section have more collapse at basal lung levels than women who had a vaginal delivery
9

Avaliação da aeração e edema pulmonar por meio de tomografia computadorizada em pacientes submetidos a revascularização do miocárdio / Evaluation of the aeration and edema pulmonary by means of computed tomography in patients undergoing coronary artery bypass graft

Rodrigues, Roseny dos Reis 30 August 2010 (has links)
Introdução: A disfunção respiratória é uma das complicações de maior prevalência no período pós-operatório de pacientes submetidos à cirurgia de revascularização do miocárdio (RM) com circulação extracorpórea (CEC), mesmo na ausência de doença pulmonar prévia1. Por meio de tomografia computadorizada, foram investigadas as alterações pulmonares pósoperatórias e o seu impacto na oxigenação. Métodos: vinte pacientes não hipoxêmicos em programação de cirurgia eletiva de revascularização do miocárdio com CEC foram estudados. Medidas hemodinâmicas, e amostras sanguíneas seriadas foram obtidas antes da cirurgia, após a intubação orotraqueal, após a CEC, na UTI, 12h, 24h e 48h após a cirurgia. Tomografias volumétricas pré e pós-operatórias foram adquiridas em condições de apneia após uma expiração espontânea. Os dados foram analisados usando teste de t Student; o comportamento temporal dos dados hemodinâmicos e outras variáveis fisiológicas foi analisado ao longo do tempo, usando análise de variância de uma via para repetidas medidas, seguido pelo teste de Student-Neumann-Keuls, quando necessário.Resultados: a relação PaO2/FiO2 diminuiu de forma significativa após a indução da anestesia, atingindo o seu nadir após a saída de CEC. Comparando-se com a TC pré-operatória, foi observada uma redução de 31% no volume de gás pulmonar (p<0,001), ao passo que foi observado um aumento do volume de tecido de 19% (p<0,001). A área não aerada dos pulmões aumentou de 253 97 g(p < 0.001), de 3 % a 27 %, após a cirurgia; e a área pobremente aerada pulmonar apresentou aumento de 72 68 g (p < 0.001), de 24 % to 27 %, enquanto a área normalmente aerada pulmonar reduziu de 147 119 g (p < 0.001), que representa 72 % to 46%. Não foram observadas correlações entre a relação PO2/FIO2 ou na fração de shunt nas primeiras 24 horas pós-operatórias Conclusões: A estrutura pulmonar está profundamente modificada após a cirurgia de RM com CEC. Associadas a outros fatores, essas alterações são responsáveis pela ocorrência de hipoxemia resultantes de atelectasias / Introduction: Hypoxemia is a frequent complication after coronary artery bypass graft (CABG) with cardiopulmonary bypass (CPB), usually attributed to atelectasis. Using computed tomography (CT), we investigated pulmonary alterations postoperatively and its impact on oxygenation. Methods: Twenty non-hypoxemic patients with normal cardiac function scheduled to CABG under CPB were studied. Hemodynamic measurements and blood samples were obtained before surgery, after intubation, after CPB, at ICU admission, 12h, 24h and 48h after surgery. Pre and postoperative volumetric thoracic CT scans were acquired in apnea conditions after a spontaneous expiration. Data was analyzed using paired Student t test and two-way repeated measures analysis of variance followed by SNK test when indicated. Results: PaO2/FiO2 ratio was significantly reduced after anesthesia induction, reaching its nadir after CPB and partially ameliorating 12h after surgery. Compared to preoperative CT, there was a postoperative 31 % reduction in pulmonary gas volume (p < 0.001) while tissue volume increased by 19 % (p < 0.001). Non-aerated lung increased by 253 97 g(p < 0.001), from 3 % to 27 %, after surgery and poorly-aerated lung by 72 68 g (p < 0.001), from 24 % to 27 % while normally-aerated lung was reduced by 147 119 g (p < 0.001), from 72 % to 46 %. No correlations were observed between PaO2/FiO2 ratio or shunt fraction at 24 h postoperatively and postoperative lung alterations. Conclusions: Lung structure is profoundly modified after CABG with CPB. Taken together, these multiple alterations occurring in the lungs are responsible for postoperative hypoxemia instead of atelectasis alone
10

Avaliação do uso de baixos volumes correntes, associados ou não a manobras de recrutamento alveolar, na oxigenação de cães submetidos a ventilação mecânica / Evaluation use of low tidal volumes oxygenation, with or without the alveolar recruitment maneuvers, in dogs undergoing mechanical ventilation

Rodrigues, Renata Ramos 09 November 2018 (has links)
Hipercapnia, hipóxia e atelectasia pulmonar são eventos comuns em pacientes anestesiados. A ventilação mecânica pode ser usada nesses casos para garantir adequada troca de gases dos pacientes e melhora da oxigenação, porém seu uso implica em efeitos hemodinâmicos e pulmonares indesejáveis. Para minimizar estes, baixos valores volumes correntes são recomendados, além do uso de pressão positiva ao final da expiração (PEEP) e manobras de recrutamento alveolar (MRA). Este estudo intencionou avaliar o uso de volume corrente de 8mL/kg, além do uso de PEEP associada, ou não, a MRA quanto a oxigenação e troca gasosa de cães jovens, ASA I e II, submetidos a anestesia geral inalatória, para cirurgias ortopédicas e odontológicas, durante 1 hora e que permaneceram em decúbito dorsal. Para tanto, foram utilizados 27 cães, divididos em 2 grupos (14 no grupo PEEP e 13 no grupo MRA) de acordo com o uso isolado de PEEP ou associado a MRA. Todos os pacientes receberam acepromazina 0,03 mg/kg associada a meperidina 3 mg/kg (IM) como MPA, indução realizada com propofol em dose suficiente para intubação orotraqueal e manutenção realizada com isoflurano 1,0 a 1,6% em FiO2 de 50%. Todos os cães foram mantidos em decúbito dorsal logo após intubação, instituição do protocolo de ventilação determinado de acordo com o grupo em que foi alocado e uso de bloqueador neuromuscular rocurônio na dose de 0,6 mg/kg (IV). Após 15 minutos de instrumentação e estabilização do plano anestésico os dados de mecânica ventilatória, gasometria arterial, oxigenação e hemodinâmica foram coletados (M0). No grupo em que se realizou MRA, a PEEP saiu de 0, sofrendo acréscimos de 5 cmH2O a cada 3 minutos, chegando a 15 e retornando gradativamente a 5 cmH2O, pressão na qual foi mantido durante o resto do tempo anestésico. No grupo PEEP foi instituída a pressão de 5 cmH2O, sendo mantida até a extubação. Ao final da MRA (M15 15 minutos após M0) todos foram novamente coletados, assim como em M30 e M60 (respectivamente, 30 e 60 minutos após M15). Através dos parâmetros de capnometria, observou-se que o volume corrente utilizado foi eficiente para garantir troca gasosa em todos os pacientes incluídos no estudo. O uso da MRA foi suficiente para reabrir as áreas colapsadas do pulmão em M0, porém, quando comparado seus índices de oxigenação e complacência com aqueles encontrados no grupo PEEP, não houve superioridade de um dos grupos. O uso de PEEP 5 cmH2O foi capaz de manter os alvéolos sem sofrer re- colapso ao longo do período do estudo. O uso de MRA ou PEEP não interferiu nos parâmetros de hemodinâmica dos cães inseridos no estudo. / Hypercapnia, hypoxia and pulmonary atelectasis are common events in anesthetized patients. Mechanical ventilation can be used in these cases to ensure adequate gas exchange of patients and improvement of oxygenation, but its use implies undesirable hemodynamic and pulmonary effects. To minimize these, low tidal volumes are recommended, in addition to the use of positive end-expiratory pressure (PEEP) and alveolar recruitment maneuvers (ARMs). The aim of this study was to evaluate the use of current volume of 8mL / kg, in addition to the use of PEEP, associated to oxygenation and gas exchange of young dogs, ASA I and II, submitted to general inhalation anesthesia for orthopedic surgeries and dental implants for 1 hour and remained in the supine position. For this, 27 dogs were used, divided into 2 groups (14 in the PEEP group and 13 in the ARM group) according to the use of PEEP alone or associated with ARM. All patients received acepromazine 0.03 mg / kg associated with meperidine 3 mg / kg (IM) as MPA, induction with propofol in sufficient doses for orotracheal intubation and maintenance with isoflurane 1.0 to 1.6% in FiO2 of 50%. All dogs were kept in dorsal decubitus position immediately after intubation, ventilation protocol established according to the group in which they were allocated and use of neuromuscular blocker rocuronium at the dose of 0.6 mg / kg (IV). After 15 minutes of instrumentation and stabilization of the anesthetic plane the data of ventilatory mechanics, arterial blood gases, oxygenation and hemodynamics were collected (M0). In the group which was held MRA left PEEP 0, 5 cmH2O suffering increases every 3 minutes, reaching 15 and returning gradually to 5 cmH 2 O, in which pressure was maintained for the rest of the duration of anesthesia. In the PEEP group, a pressure of 5 cmH2O was instituted and maintained until extubation. At the end of the ARM (M15 - 15 minutes after M0) all were collected again, as well as in M30 and M60 (respectively, 30 and 60 minutes after M15). Through the parameters of capnometry, it was observed that the tidal volume used was efficient to guarantee gas exchange in all patients included in the study. The use of MRA was enough to reopen the collapsed lung areas M0, but compared their levels of oxygenation and compliance with those found in the PEEP group, there was no superiority of one group. The use of PEEP 5 cmH2O was able to maintain the alveoli without undergoing re-collapse over the study period. The use of MRA or PEEP did not interfere in the hemodynamic parameters of the dogs inserted in the study.

Page generated in 0.4168 seconds