• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • Tagged with
  • 21
  • 21
  • 21
  • 19
  • 19
  • 17
  • 12
  • 12
  • 11
  • 11
  • 11
  • 11
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efetividade da espirometria de incentivo na prevenção de complicações pulmonares após cirurgia de revascularização da artéria coronária: revisão sistemática e metanálise / Efectiveness of incentive spirometry for preventing pulmonary complications following coronary artery bypass grafts: systemic review and meta-analyse

Freitas, Eliane Regina Ferreira Sernache de [UNIFESP] January 2006 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:07:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2006 / INTRODUÇÃO: A espirometria de incentivo tem permanecido uma técnica de fisioterapia cardiorrespiratória amplamente usada para profilaxia e tratamento de complicações respiratórias em pacientes pós-cirúrgicos. OBJETIVOS: Avaliar a efetividade da espirometria de incentivo na prevenção de complicações pulmonares pós-operatória em adultos submetidos à cirurgia de revascularização da artéria coronária. MÉTODOS: O tipo de estudo utilizado foi a revisão sistemática de ensaios clínicos aleatórios. Foram utilizadas oito bases de dados (Medline, Embase, Cinahl, Lilacs, CENTRAL - Cochrane Field Rehabilitation and related therapies, PeDro, AMED e DARE) com suas respectivas estratégias de busca, referências de artigos e revistas especializadas, sem restrição de idiomas na sua identificação. Foram incluídos estudos sobre o uso da espirometria de incentivo em pacientes submetidos à cirurgia de revascularização da artéria coronária. Os desfechos clínicos analisados foram atelectasia, pneumonia, capacidade vital, volume expiratório forçado no 1° segundo, pressão parcial de oxigênio arterial pela fração inspirada de oxigênio e tempo de permanência hospitalar. A qualidade dos métodos foi avaliada segundo a ocultação da alocação, conforme a metodologia da Colaboração Cochrane, e de acordo com a lista Delphi, por dois avaliadores independentes. Os dados dos estudos foram extraídos por meio de uma ficha padronizada. Para avaliar a concordância dos resultados da qualidade dos estudos, foi usado o teste Kappa. Para as variáveis contínuas, foi calculada a diferença da média ponderada (efeito fixo), e para as variáveis categóricas foi calculada a razão de chances de ocorrência dos eventos (Odds Ratio), ambos com intervalo de confiança de 95 por cento. RESULTADOS: Sete ensaios clínicos preencheram os critérios de inclusão, porém somente quatro estudos foram incluídos para metanálise, num total de 443 participantes (184 espirometria de incentivo; 259 controle). Nenhum dos estudos incluídos descreveu de forma adequada a ocultação de alocação. Não encontramos nenhuma evidência de diferença estatística significante de efeito estimado de risco (OR) a favor da espirometria de incentivo na prevenção de complicações pulmonares, quando comparada às outras técnicas de fisioterapia cardiorrespiratória ou ao grupo que não foi submetido à um programa sistematizado de fisioterapia. CONCLUSÃO: Evidências existentes não apóiam o uso da espirometria de incentivo para prevenir complicações pulmonares nos pacientes submetidos à cirurgia de revascularização da artéria coronária / Introduction: The Incentive spirometry remains the most widely used cardiorespiratory physiotherapy technique for the prevention and treatment of respiratory complications in post-operative patients. Objectives: To evaluate the effectiveness of incentive spirometry in the prevention of postoperative pulmonary complications in adults who underwent coronary artery bypass graft. Methods: A systematic review of random clinical trials was carried out, using information from nine data bases (Medline, Embase, Cinahl, Lilacs, CENTRAL, Cochrane Field Rehabilitation and related therapies, PeDro, AMED, and DARE) with their respective search strategies, as well as articles and specialized magazine references, with no restriction to language. Studies on the use of incentive spirometry in patients who underwent coronary artery bypass graft were included. Clinical outcomes were atelectasis, pneumonia, vital capacity, forced expiratory volume in 1 second, partial pressure of arterial oxygen per oxygen inspired fraction and the durations of total hospital stay. Method quality was assessed according of concealment of allocation, in agreement with the Cochrane Collaboration Method and the Delphi List, by two independent evaluators. Data were collected by a standardized record file. The Kappa Test was used to evaluate agreement among quality studies results. The difference between average means (fixed effect) was calculated for the continuous variables, and the Odds Ratio was used for the categorical variables, both with a reliability interval of 95%. Results: Seven clinical trials met the eligibility criteria, however only four studies were included for meta-analysed. In total 443 patients were enrolled (184 treatment group, 259 control group). None of the included studies described adequately the concealment allocation procedure. We did not find any evidence of statistical difference accompanied of estimated effect of risk (OR) and confidence interval of 95% in favor of incentive espirometry in the prevention of pulmonary complications when compared to other cardiorespiratory physical therapy techniques or the physiotherapy absence. Conclusion: The evidences do not support the use of incentive espirometry to prevent pulmonary complications in the patients undergoing coronary artery bypass graft. / BV UNIFESP: Teses e dissertações
2

Fluxometria intraoperatória do enxerto composto de artéria torácica interna esquerda e veia safena magna / Flowmetry intraoperative compound graft of the left internal thoracic artery and saphenous vein

Lobo Filho, Heraldo Guedis 01 July 2016 (has links)
LOBO FILHO, H. G. Fluxometria intraoperatória do enxerto composto de artéria torácica interna esquerda e veia safena magna. 2016. 127 f. Tese (Doutorado em Cirurgia) - Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-08-23T12:04:12Z No. of bitstreams: 1 2016_tese_hglobofilho.pdf: 4731832 bytes, checksum: 0646a49406446131b25d2348e4e01d8f (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2016-08-23T12:04:19Z (GMT) No. of bitstreams: 1 2016_tese_hglobofilho.pdf: 4731832 bytes, checksum: 0646a49406446131b25d2348e4e01d8f (MD5) / Made available in DSpace on 2016-08-23T12:04:19Z (GMT). No. of bitstreams: 1 2016_tese_hglobofilho.pdf: 4731832 bytes, checksum: 0646a49406446131b25d2348e4e01d8f (MD5) Previous issue date: 2016-07-01 / Composite graft of left internal thoracic artery (LITA) and great saphenous vein (GSV) in the revascularization of two or more arteries of the left coronary system (LCS) is a technique described in literature since the 1980s. Despite recent studies demonstrating that LITA is capable of providing adequate blood flow for two or more LCS arteries, both in basal condition and under stress, deeper studies must be developed to improve this knowledge. The objective of this study was to analyze blood flow dynamics in this kind of composite graft, specially in what concerns to LITA adaptability and to the influence of GSV segment on LITA flow. In 23 patients, a LITA and GVS composite Y-graft was realized to the anterior interventricular artery (AIA) and to another LCS branch, respectively, without extracorporeal circulation. Mean blood flow, as well as parameters of graft patency (diastolic fraction and pulsatile index) and coronary flow reserve (CFR) were evaluated through transit time flowmetry (TTFM) in all segments of the composite graft, which are LITA proximal and distal segments, and GSV segment. The measures were realized in basal condition and after dobutamine-induced pharmacological stress, as well as without and with non-traumatic temporary clamping of the distal segments of composite graft. Pharmacological stress resulted in increased values of blood flow in all analyzed segments (p<0,05). Non-traumatic temporary clamping of GSV segments did not cause statistically significant changes in mean blood flow of LITA distal segment, as much in basal situation as under pharmacological stress, without modification of the CFR. Likewise, non-traumatic temporary clamping of LITA distal segment did not cause statistically significant changes in mean blood flow of GSV segment, as much in basal situation as under pharmacological stress, without modification of the CFR. In conclusion, evaluation through TTFM of mean blood flow, diastolic fraction, pulsatile index and coronary flow reserve in LITA and GSV composite graft to revascularize AIA and another LCS branch, respectively, evidenced blood flow dynamics with physiologic adaptability in all segments, both in basal situation and under stress, in other words, in accordance to the flow demand. The presence of GSV segment in the composite graft refereed pattern did not change physiological dynamics of blood flow in LITA distal segment. / Enxerto composto de artéria torácica interna esquerda (ATIE) e veia safena magna (VSM) na revascularização de duas ou mais artérias do sistema coronariano esquerdo (SCE) é uma técnica descrita na literatura desde a década de 1980. Apesar de recentes estudos demonstrarem que a ATIE é capaz de oferecer fluxo sanguíneo adequado, para duas ou mais artérias do SCE, tanto em situação de repouso como estresse, estudos aprofundados devem ser desenvolvidos para aprimorar esse conhecimento. O objetivo deste trabalho é analisar a dinâmica de fluxo sanguíneo neste tipo de enxerto composto, sobretudo no que concerne a adaptabilidade da ATIE e à influência da presença do segmento de VSM sobre o fluxo na ATIE. Em vinte e três pacientes foi realizado enxerto composto em Y de ATIE e VSM, para revascularizar a artéria interventricular anterior (AIA) e outro ramo do SCE, respectivamente, sem circulação extracorpórea (CEC). O fluxo sanguíneo médio , parâmetros de perviedade do enxerto (fração diastólica e índice de pulsatilidade) e reserva de fluxo coronariano (RFC) foram avaliados por meio de fluxometria por tempo de trânsito (FMTT) em todos os segmentos do enxerto composto, ou seja, nos segmentos proximal e distal da ATIE e no segmento de VSM. As medidas foram realizadas em condição basal, e após estresse farmacológico com dobutamina, bem como sem e com clampeamento temporário atraumático dos segmentos distais do enxerto composto. Estresse farmacológico resultou em aumento dos valores do fluxo sanguíneo em todos os segmentos analisados (p<0,05). O clampeamento temporário atraumático do segmento de VSM não causou alteração estatisticamente significativa do fluxo sanguíneo médio no segmento distal da ATIE, tanto em situação basal, como sob estresse farmacológico, não modificando a RFC. Da mesma forma, o clampeamento temporário atraumático do segmento distal de ATIE não causou alteração estatisticamente significativa do fluxo sanguíneo médio no segmento de VSM, tanto em situação basal, como sob estresse farmacológico, não modificando a RFC. Em conclusão, a análise por FMTT evidenciou que o enxerto composto de ATIE e VSM para revascularização da AIA e outro ramo do SCE apresentou uma dinâmica de fluxo sanguíneo com adaptabilidade fisiológica em todos os segmentos, tanto em situação de repouso como de estresse, ou seja, de acordo com a demanda. A presença do segmento de VSM na disposição do enxerto em questão, não alterou a dinâmica fisiológica do fluxo sanguíneo no segmento distal da ATIE.
3

Alterações hemostáticas e clínicas em cirurgias de revascularização miocárdica com e sem circulação extracorpórea: estudo prospectivo randomizado / Hemostatic changes and clinical sequelae after on-pump compared with off-pump coronary artery bypass surgery: a prospective randomized study

Paulitsch, Felipe da Silva 07 January 2010 (has links)
Introdução: a revascularização miocárdica (RM) sem circulação extracorpórea (CEC) tem sido associada a menores complicações quando comparadas à com CEC. Objetivos: determinar os efeitos da CEC em marcadores de hemostasia, fibrinólise, inflamação e correlacionar com eventos clínicos. Método: os pacientes foram incluídos de forma prospectiva e randomizada para cirurgia de RM com (n=41) ou sem CEC (n=51). As concentrações de proteína C reativa (PCR), fibrinogênio, dímero-D e inibidor do ativador do plasminogênio tipo 1 (PAI1) foram quantificadas antes e após (1 e 24 horas) a RM. As técnicas cirúrgicas e anestésicas foram padronizadas para ambos os grupos. Eventos clínicos foram avaliados durante a hospitalização inicial e após 1 ano de seguimento. Resultados: as concentrações de PAI1 e dímeros-d foram maiores quando comparados os valores pré-operatórios com os de 1 e 24 h, após a RM em ambos os grupos, porém as concentrações de PAI1 aumentadas estenderam-se por 24 h após a RM com CEC (p<0,01). A concentração de PCR teve um aumento de pequena magnitude imediatamente após a cirurgia em ambos os grupos e aumentou de modo similar 24h após a RM (p<0,01). A RM com CEC foi associada com maior perda sanguínea durante a cirurgia e mais sangramento pós-operatório (p<0,01). A incidência de todas as outras complicações foi similar nos dois grupos. Conclusão: a RM com CEC apresentou evidências bioquímicas de um estado pró-trombótico precoce após a cirurgia, porém, sem evidências no aumento no número de eventos trombóticos. O estado pró-trombótico pode ser consequência do circuito extracorpóreo, resposta compensatória ao sangramento, ou a ambos em pacientes submetidos à cirurgia com CEC. / Objective: To delineate the effects of extracorporeal bypass on biomarkers of hemostasis, fibrinolysis, and inflammation and clinical sequelae. Methods: Patients were assigned prospectively and randomly to either on-pump (n=41) or off-pump (n=51) coronary bypass surgery. The concentrations of C-reactive protein (CRP), fibrinogen, D-dimer, and plasminogen activator inhibitor type 1 (PAI-1) in blood were quantified before and after (1 hour and 24 hours) surgery. Similar surgical and anesthetic procedures were used for both groups. Clinical events were assessed during initial hospitalization and at the end of 1 year. Results: The concentrations of PAI-1 and d-dimer were greater compared with preoperative values 1 hour and 24 hours after surgery in both groups, but their concentrations increased to a greater extent 24 hours after surgery in the on-pump group (p<0.01). The concentration of CRP did not change appreciably immediately after surgery in either group but increased in a parallel fashion 24 hours after either on-pump or off-pump surgery (p<0.01). Bypass surgery in the on-pump group was associated with greater blood loss during surgery and more bleeding after surgery (p0.01). The incidence of all other complications was similar in the 2 groups. Conclusion: On-pump surgery was associated with biochemical evidence of a pro-thrombotic state early after surgery but no greater incidence of thrombotic events. The pro-thrombotic state may have been a consequence of extracorporeal bypass, compensation in response to more bleeding, or both in patients undergoing on-pump surgery.
4

Alterações hemostáticas e clínicas em cirurgias de revascularização miocárdica com e sem circulação extracorpórea: estudo prospectivo randomizado / Hemostatic changes and clinical sequelae after on-pump compared with off-pump coronary artery bypass surgery: a prospective randomized study

Felipe da Silva Paulitsch 07 January 2010 (has links)
Introdução: a revascularização miocárdica (RM) sem circulação extracorpórea (CEC) tem sido associada a menores complicações quando comparadas à com CEC. Objetivos: determinar os efeitos da CEC em marcadores de hemostasia, fibrinólise, inflamação e correlacionar com eventos clínicos. Método: os pacientes foram incluídos de forma prospectiva e randomizada para cirurgia de RM com (n=41) ou sem CEC (n=51). As concentrações de proteína C reativa (PCR), fibrinogênio, dímero-D e inibidor do ativador do plasminogênio tipo 1 (PAI1) foram quantificadas antes e após (1 e 24 horas) a RM. As técnicas cirúrgicas e anestésicas foram padronizadas para ambos os grupos. Eventos clínicos foram avaliados durante a hospitalização inicial e após 1 ano de seguimento. Resultados: as concentrações de PAI1 e dímeros-d foram maiores quando comparados os valores pré-operatórios com os de 1 e 24 h, após a RM em ambos os grupos, porém as concentrações de PAI1 aumentadas estenderam-se por 24 h após a RM com CEC (p<0,01). A concentração de PCR teve um aumento de pequena magnitude imediatamente após a cirurgia em ambos os grupos e aumentou de modo similar 24h após a RM (p<0,01). A RM com CEC foi associada com maior perda sanguínea durante a cirurgia e mais sangramento pós-operatório (p<0,01). A incidência de todas as outras complicações foi similar nos dois grupos. Conclusão: a RM com CEC apresentou evidências bioquímicas de um estado pró-trombótico precoce após a cirurgia, porém, sem evidências no aumento no número de eventos trombóticos. O estado pró-trombótico pode ser consequência do circuito extracorpóreo, resposta compensatória ao sangramento, ou a ambos em pacientes submetidos à cirurgia com CEC. / Objective: To delineate the effects of extracorporeal bypass on biomarkers of hemostasis, fibrinolysis, and inflammation and clinical sequelae. Methods: Patients were assigned prospectively and randomly to either on-pump (n=41) or off-pump (n=51) coronary bypass surgery. The concentrations of C-reactive protein (CRP), fibrinogen, D-dimer, and plasminogen activator inhibitor type 1 (PAI-1) in blood were quantified before and after (1 hour and 24 hours) surgery. Similar surgical and anesthetic procedures were used for both groups. Clinical events were assessed during initial hospitalization and at the end of 1 year. Results: The concentrations of PAI-1 and d-dimer were greater compared with preoperative values 1 hour and 24 hours after surgery in both groups, but their concentrations increased to a greater extent 24 hours after surgery in the on-pump group (p<0.01). The concentration of CRP did not change appreciably immediately after surgery in either group but increased in a parallel fashion 24 hours after either on-pump or off-pump surgery (p<0.01). Bypass surgery in the on-pump group was associated with greater blood loss during surgery and more bleeding after surgery (p0.01). The incidence of all other complications was similar in the 2 groups. Conclusion: On-pump surgery was associated with biochemical evidence of a pro-thrombotic state early after surgery but no greater incidence of thrombotic events. The pro-thrombotic state may have been a consequence of extracorporeal bypass, compensation in response to more bleeding, or both in patients undergoing on-pump surgery.
5

"Estudo comparativo de dois métodos de registro de diagnósticos e intervenções de enfermagem em pacientes durante o transoperatório de cirurgia de revascularização do miocárdio" / Comparative study of two recording methods of nursing diagnosis and interventions during the intraoperative period for patients undergoing coronary artery bypass graft surgery (CABG)

Ribeiro, Floracy Gomes 12 July 2006 (has links)
Este trabalho teve como objetivo comparar as freqüências e concordâncias em percentual os registros de diagnósticos e intervenções de enfermagem entre dois métodos: Sistematização de Assistência de Enfermagem (SAEP) e o Conjunto de Dados de Enfermagem Perioperatória (PNDS) no transoperatório de RM, Os métodos foram empregados por 2 grupos distintos de enfermeiros em 50 pacientes. Os registros encontrados no SAEP foram transcritos, mapeados para o PNDS e então comparados. No PNDS registrou-se 648 diagnósticos e no SAEP 38. A freqüência de intervenções registradas para o PNDS foi 1863 e para SAEP 1587. Não houve concordância em percentual para a presença de diagnósticos entre os métodos estudados. Nas intervenções do domínio segurança, houve concordância acima de 70% em 12 categorias / This study aimed to compare frequency and percentage agreement of nursing diagnosis and interventions documented by two different methods: Perioperative Nursing Care Process (SAEP) and Perioperative Nursing Data Set (PNDS) during intra-operative CABG surgery. The methods were employed by two distinct groups of nurses with 50 patients. SAEP nursing documentation was transcribed, mapped and compared to PNDS. With the PNDS documentation, 648 nursing diagnosis were recorded and 38 with SAEP. Nursing interventions frequency for PNDS were 1863 and SAEP, 1587. There was no percentage agreement of nursing diagnosis between the studied methods. There was over 70% agreement for safety domain interventions, in 12 categories
6

"Estudo comparativo de dois métodos de registro de diagnósticos e intervenções de enfermagem em pacientes durante o transoperatório de cirurgia de revascularização do miocárdio" / Comparative study of two recording methods of nursing diagnosis and interventions during the intraoperative period for patients undergoing coronary artery bypass graft surgery (CABG)

Floracy Gomes Ribeiro 12 July 2006 (has links)
Este trabalho teve como objetivo comparar as freqüências e concordâncias em percentual os registros de diagnósticos e intervenções de enfermagem entre dois métodos: Sistematização de Assistência de Enfermagem (SAEP) e o Conjunto de Dados de Enfermagem Perioperatória (PNDS) no transoperatório de RM, Os métodos foram empregados por 2 grupos distintos de enfermeiros em 50 pacientes. Os registros encontrados no SAEP foram transcritos, mapeados para o PNDS e então comparados. No PNDS registrou-se 648 diagnósticos e no SAEP 38. A freqüência de intervenções registradas para o PNDS foi 1863 e para SAEP 1587. Não houve concordância em percentual para a presença de diagnósticos entre os métodos estudados. Nas intervenções do domínio segurança, houve concordância acima de 70% em 12 categorias / This study aimed to compare frequency and percentage agreement of nursing diagnosis and interventions documented by two different methods: Perioperative Nursing Care Process (SAEP) and Perioperative Nursing Data Set (PNDS) during intra-operative CABG surgery. The methods were employed by two distinct groups of nurses with 50 patients. SAEP nursing documentation was transcribed, mapped and compared to PNDS. With the PNDS documentation, 648 nursing diagnosis were recorded and 38 with SAEP. Nursing interventions frequency for PNDS were 1863 and SAEP, 1587. There was no percentage agreement of nursing diagnosis between the studied methods. There was over 70% agreement for safety domain interventions, in 12 categories
7

Avaliação hemodinâmica durante a revascularização do miocárdio sem utilização de circulação extracorpórea / Hemodynamic evaluation during off-pump coronary artery bypass surgery

Kim, Silvia Minhye 23 April 2008 (has links)
INTRODUÇÃO: A cirurgia de revascularização miocárdica sem utilização de circulação extracorpórea (CEC) tem sido cada vez mais utilizada, especialmente após a introdução de dispositivos estabilizadores da parede cardíaca. Entretanto, a técnica pode causar alterações hemodinâmicas durante a realização das anastomoses coronárias. OBJETIVOS: Analisar as alterações hemodinâmicas decorrentes das mudanças de posição do coração para abordar as artérias coronárias sem CEC e comparar os monitores de débito cardíaco semi-contínuo e de ecodoppler transesofágico quanto à precisão das medidas hemodinâmicas. MATERIAL E MÉTODOS: Foram selecionados aleatoriamente 20 pacientes adultos com idade inferior a 80 anos, candidatos a cirurgia eletiva de revascularização miocárdica sem utilização de circulação extracorpórea. A avaliação hemodinâmica incluiu a utilização de ecodopppler com transdutor esofágico e de cateter de artéria pulmonar com filamento térmico. A coleta de dados foi realizada: 1 - após a indução da anestesia, antes do início da revascularização propriamente dita, 2 - durante a realização das anastomoses distais, logo após o posicionamento e estabilização do coração e 3 - após cinco minutos do início da anastomose. Os dados hemodinâmicos foram analisados por análise de variância de duplo fator com repetição, complementada por teste de Newman-Keuls. O nível de significância considerado foi de 5%. Os valores de débito cardíaco foram comparados segundo método proposto por Bland e Altman, analisando a correlação intraclasses, diferenças médias e intervalos de confiança de 95%. RESULTADOS: Alterações hemodinâmicas significativas foram detectadas para o aumento de pressão de oclusão de artéria pulmonar (de 17,7 ± 6,1 para 19,2 ± 6,5 mmHg - p<0,001 e para 19,4 ± 5,8 mmHg - p<0,001) e pressão venosa central (de 13,9 ± 5,4 para 14,9 ± 5,9 mmHg - p=0,007 e para 15,1 ± 6,0 mmHg - p=0,006), além de diminuição do débito cardíaco obtido por termodiluição intermitente (de 4,70 ± 1,43 para 4,23 ± 1,22 L/min - p<0,001 e para 4,26 ± 1,27 L/min - p<0,001). Houve interação grupo-tempo estatisticamente significativa no débito cardíaco por Doppler esofágico, que apresentou redução no grupo lateral de 4,08 ± 1,99 para 2,84 ± 1,81 L/min (p=0,02) e para 2,86 ± 1,73 L/min (p=0,02), e no fluxo sanguíneo aórtico, que diminuiu de 2,85 ± 1,39 para 1,99 ± 1,26 L/min (p=0,02) e para 2,00 ± 1,21 L/min (p=0,02). As medidas de débito cardíaco intermitente, semicontínuo e por Doppler esofágico apresentaram diferenças médias e intervalos de confiança de 95% acima de limites aceitáveis clinicamente. CONCLUSÕES: Houve deterioração hemodinâmica significativa durante a revascularização miocárdica sem CEC. Pelo Doppler esofágico, o débito cardíaco apresentou redução detectada apenas na parede lateral. As diferenças nos valores de débito cardíaco foram muito amplas para considerar os métodos concordantes, em quaisquer das condições hemodinâmicas estudadas. / INTRODUCTION: Coronary artery bypass graft (CABG) surgeries have been performed increasingly without cardiopulmonary bypass (off-pump CABG), specially with introduction of cardiac wall stabilizing devices. However, hemodynamic changes can occur during coronary anastomosis. OBJECTIVES: To study hemodynamic alterations caused when cardiac position is changed to operate coronary arteries and to compare continuous cardiac output and esophageal Doppler monitor regardig accuracy of hemodynamic measurements. MATERIALS AND METHODS: Twenty adult patients under age of 80 undergoing elective off-pump CABG were enrolled. Hemodynamic evaluation was performed with esophageal echodoppler and continuous thermodilution pulmonary artery catheter. Data were collected 1 - after induction of anesthesia, before revascularization, 2 - during distal anastomosis, right after heart positioning and stabilization, and 3 - five minutes following the beginning of anastomosis. Repeated measures two-way ANOVA with post hoc Newman-Keuls tests were used to analyse hemodynamic data and level of significance was set at 0.05. Cardiac output values were compared using the method proposed by Bland and Altman, and included analysis of correlation, mean differences and 95% confidence intervals. RESULTS: Significant hemodynamic alterations were detected during revascularization of coronary arteries as elevation of pulmonary artery occlusion pressure (from 17.7 ± 6.1 to 19.2 ± 6.5 mmHg - P <0.001, and to 19.4 ± 5.8 mmHg - P <0.001) and of central venous pressures (from 13.9 ± 5.4 to 14.9 ± 5.9 mmHg - P =0.007, and to 15.1 ± 6.0 mmHg - P =0.006), and as reduction of intermittent cardiac output (from 4.70 ± 1.43 to 4.23 ± 1.22 l/min - P <0.001, and to 4.26 ± 1.27 l/min - P <0.001). Statistically significant group-time interaction was observed in esophageal Doppler cardiac output, that decreased in the lateral wall from 4.08 ± 1.99 to 2.84 ± 1.81 l/min (P =0.02) and to 2.86 ± 1.73 l/min (P =0.02), and in aortic blood flow, that decreased from 2.85 ± 1.39 to 1.99 ± 1.26 l/min (P =0,02) and to 2.00 ± 1.21 l/min (P =0.02). Intermittent, STAT-mode or esophageal Doppler cardiac output mean differences and 95% confidence intervals were beyond clinically acceptable limits. CONCLUSIONS: There was significant hemodynamic deterioration during off-pump CABG. On the esophageal Doppler monitor, cardiac output decrease was detected only in the lateral wall. Differences in cardiac output measurements were too wide to say methods agreed, in all hemodynamic conditions studied.
8

DIFERENÇA DA MORTALIDADE ENTRE OS SEXOS APÓS CIRURGIA DE REVASCULARIZAÇÃO DO MIOCARDIO / DIFFERENCE OF THE MORTALITY BETWEEN THE SEXES AFTER CABG SURGERY

Coutinho, Léa Barroso 20 April 2012 (has links)
Made available in DSpace on 2016-08-19T18:16:06Z (GMT). No. of bitstreams: 1 dissertacao Lea.pdf: 69266 bytes, checksum: f60351433176b7ed5ac2e326bfa1bf71 (MD5) Previous issue date: 2012-04-20 / Objective: To compare the mortality of men and women undergoing coronary artery bypass surgery (CABG) alone and identifying factors related differences occasionally found. Methods: Retrospective cohort study conducted with 215 patients who underwent coronary bypass surgery consecutively from January 2007 to December 2008. Results: Women had a higher average age. Low body surface and dyslipidemia was more prevalent in women (1.65 vs. 1.85, p <0.001: 53% vs 30%, p = 0.001), whereas smoking history and previous myocardial infarction were more prevalent among men (35 % vs 14.7% p = 0.001, 20% vs 2.7%, p = 0.007). Regarding the complications in the postoperative period, there was a higher rate of transfusions in women. The overall mortality rate was 5.6%, however there was no statistically significant difference in mortality between men and women. It was observed that among patients who died the mean body surface was lower than that of patients who progressed without this complication. Conclusion: There was no difference in mortality between the sexes after CABG in our department. / Objetivo: Comparar a morbimortalidade de homens e mulheres submetidos à cirurgia de revascularização isolada e identificando fatores relacionados as diferenças eventualmente encontradas. Métodos: Estudo de Coorte retrospectivo realizado com 215 pacientes, submetidos a cirurgia de revascularização miocárdica isolada, consecutivamente, de janeiro de 2007 a dezembro de 2008. Resultados: As mulheres apresentaram idade media mais elevada. Baixa superfície corpórea e dislipidemia foram mais prevalentes nas mulheres (1,65 vs 1,85, p<0,001: 53% vs 30%, p=0,001), enquanto história de tabagismo e infarto do miocárdio prévio foram mais prevalentes nos homens (35% vs 14,7%p=0,001; 20% vs 2,7%, p=0,007). Em relação às complicações no pós-operatório, houve maior taxa de transfusão de hemoderivados nas mulheres. A taxa de mortalidade geral foi de 5,6%, no entanto não houve diferença estatisticamente significante na mortalidade entre homens e mulheres. Foi observado que entre os pacientes que evoluíram para óbito a media da superfície corpórea era menor que a dos pacientes que evoluíram sem essa complicação. Conclusão: Não houve diferença de mortalidade entre os sexos após revascularização miocárdica neste serviço.
9

Avaliação hemodinâmica durante a revascularização do miocárdio sem utilização de circulação extracorpórea / Hemodynamic evaluation during off-pump coronary artery bypass surgery

Silvia Minhye Kim 23 April 2008 (has links)
INTRODUÇÃO: A cirurgia de revascularização miocárdica sem utilização de circulação extracorpórea (CEC) tem sido cada vez mais utilizada, especialmente após a introdução de dispositivos estabilizadores da parede cardíaca. Entretanto, a técnica pode causar alterações hemodinâmicas durante a realização das anastomoses coronárias. OBJETIVOS: Analisar as alterações hemodinâmicas decorrentes das mudanças de posição do coração para abordar as artérias coronárias sem CEC e comparar os monitores de débito cardíaco semi-contínuo e de ecodoppler transesofágico quanto à precisão das medidas hemodinâmicas. MATERIAL E MÉTODOS: Foram selecionados aleatoriamente 20 pacientes adultos com idade inferior a 80 anos, candidatos a cirurgia eletiva de revascularização miocárdica sem utilização de circulação extracorpórea. A avaliação hemodinâmica incluiu a utilização de ecodopppler com transdutor esofágico e de cateter de artéria pulmonar com filamento térmico. A coleta de dados foi realizada: 1 - após a indução da anestesia, antes do início da revascularização propriamente dita, 2 - durante a realização das anastomoses distais, logo após o posicionamento e estabilização do coração e 3 - após cinco minutos do início da anastomose. Os dados hemodinâmicos foram analisados por análise de variância de duplo fator com repetição, complementada por teste de Newman-Keuls. O nível de significância considerado foi de 5%. Os valores de débito cardíaco foram comparados segundo método proposto por Bland e Altman, analisando a correlação intraclasses, diferenças médias e intervalos de confiança de 95%. RESULTADOS: Alterações hemodinâmicas significativas foram detectadas para o aumento de pressão de oclusão de artéria pulmonar (de 17,7 ± 6,1 para 19,2 ± 6,5 mmHg - p<0,001 e para 19,4 ± 5,8 mmHg - p<0,001) e pressão venosa central (de 13,9 ± 5,4 para 14,9 ± 5,9 mmHg - p=0,007 e para 15,1 ± 6,0 mmHg - p=0,006), além de diminuição do débito cardíaco obtido por termodiluição intermitente (de 4,70 ± 1,43 para 4,23 ± 1,22 L/min - p<0,001 e para 4,26 ± 1,27 L/min - p<0,001). Houve interação grupo-tempo estatisticamente significativa no débito cardíaco por Doppler esofágico, que apresentou redução no grupo lateral de 4,08 ± 1,99 para 2,84 ± 1,81 L/min (p=0,02) e para 2,86 ± 1,73 L/min (p=0,02), e no fluxo sanguíneo aórtico, que diminuiu de 2,85 ± 1,39 para 1,99 ± 1,26 L/min (p=0,02) e para 2,00 ± 1,21 L/min (p=0,02). As medidas de débito cardíaco intermitente, semicontínuo e por Doppler esofágico apresentaram diferenças médias e intervalos de confiança de 95% acima de limites aceitáveis clinicamente. CONCLUSÕES: Houve deterioração hemodinâmica significativa durante a revascularização miocárdica sem CEC. Pelo Doppler esofágico, o débito cardíaco apresentou redução detectada apenas na parede lateral. As diferenças nos valores de débito cardíaco foram muito amplas para considerar os métodos concordantes, em quaisquer das condições hemodinâmicas estudadas. / INTRODUCTION: Coronary artery bypass graft (CABG) surgeries have been performed increasingly without cardiopulmonary bypass (off-pump CABG), specially with introduction of cardiac wall stabilizing devices. However, hemodynamic changes can occur during coronary anastomosis. OBJECTIVES: To study hemodynamic alterations caused when cardiac position is changed to operate coronary arteries and to compare continuous cardiac output and esophageal Doppler monitor regardig accuracy of hemodynamic measurements. MATERIALS AND METHODS: Twenty adult patients under age of 80 undergoing elective off-pump CABG were enrolled. Hemodynamic evaluation was performed with esophageal echodoppler and continuous thermodilution pulmonary artery catheter. Data were collected 1 - after induction of anesthesia, before revascularization, 2 - during distal anastomosis, right after heart positioning and stabilization, and 3 - five minutes following the beginning of anastomosis. Repeated measures two-way ANOVA with post hoc Newman-Keuls tests were used to analyse hemodynamic data and level of significance was set at 0.05. Cardiac output values were compared using the method proposed by Bland and Altman, and included analysis of correlation, mean differences and 95% confidence intervals. RESULTS: Significant hemodynamic alterations were detected during revascularization of coronary arteries as elevation of pulmonary artery occlusion pressure (from 17.7 ± 6.1 to 19.2 ± 6.5 mmHg - P <0.001, and to 19.4 ± 5.8 mmHg - P <0.001) and of central venous pressures (from 13.9 ± 5.4 to 14.9 ± 5.9 mmHg - P =0.007, and to 15.1 ± 6.0 mmHg - P =0.006), and as reduction of intermittent cardiac output (from 4.70 ± 1.43 to 4.23 ± 1.22 l/min - P <0.001, and to 4.26 ± 1.27 l/min - P <0.001). Statistically significant group-time interaction was observed in esophageal Doppler cardiac output, that decreased in the lateral wall from 4.08 ± 1.99 to 2.84 ± 1.81 l/min (P =0.02) and to 2.86 ± 1.73 l/min (P =0.02), and in aortic blood flow, that decreased from 2.85 ± 1.39 to 1.99 ± 1.26 l/min (P =0,02) and to 2.00 ± 1.21 l/min (P =0.02). Intermittent, STAT-mode or esophageal Doppler cardiac output mean differences and 95% confidence intervals were beyond clinically acceptable limits. CONCLUSIONS: There was significant hemodynamic deterioration during off-pump CABG. On the esophageal Doppler monitor, cardiac output decrease was detected only in the lateral wall. Differences in cardiac output measurements were too wide to say methods agreed, in all hemodynamic conditions studied.
10

Eficácia e segurança do uso da ventilação não invasiva associada à manobra de recrutamento alveolar no pós-operatório de revascularização do miocárdio: ensaio clínico randomizado / Efficacy and safety of using noninvasive ventilation associated with recruitment maneuver in the postoperative period of coronary artery bypass grafting: a randomized clinical trial

Miura, Mieko Claudia 21 November 2017 (has links)
INTRODUÇÃO: Complicações pulmonares são frequentes no pós-operatório da cirurgia de revascularização do miocárdio (RM) e a ventilação não-invasiva (VNI) tem sido utilizada nos cuidados pós-operatórios de forma profilática e terapêutica. A manobra de recrutamento alveolar (MRA) consiste no aumento sustentado de pressão na via aérea utilizando um alto nível de pressão expiratória final positiva (PEEP) em indivíduos hipoxêmicos, garantindo uma ventilação pulmonar homogênea e, com isso melhorando a oxigenação arterial. O objetivo desse estudo foi de avaliar se o uso da VNI associada à MRA pode melhorar a oxigenação e se pode ser aplicada de forma segura nos pacientes pós-operatório de RM. MÉTODOS: Foram incluídos 34 pacientes internados na unidade de terapia intensiva (UTI) ventilados mecanicamente após RM com relação Pa02/Fi02 < 300 e escore radiológico de atelectasia ;:: 2. Os pacientes foram randomizados 16 para o grupo controle (GC) e 18 para o grupo recrutamento (GR), após a extubação a VNI foi aplicada por 30 minutos três vezes ao dia de acordo com a rotina da UTI. No GC a VNI era realizada com PEEP de 8 cm H20 e no GR foi aplicada PEEP de 15 cm H20 e 20 cm H20 durante 2 minutos cada e depois ficava com PEEP de 8 cm H20. Analisamos a Pa02 pela gasometria arterial em ar ambiente e o escore radiológico de atelectasia, estabilidade hemodinâmica e evento adverso até a alta da UTI. RESULTADOS: Aumento de Pa02 12,6 ± 6,8% GC e 23,3 ± 8,5% GR com p < 0,001, o escore radiológico de atelectasia apresentou resolução completa em 94,4% GR, enquanto que no GC, 87,5% apresentou algum grau de atelectasia, p < 0,001. Não houve eventos adversos relacionados. CONCLUSÃO: o uso por 30 minutos da VNI associada à MRA foi seguro, melhorou a oxigenação e reduziu a atelectasia / BACKGROUND: Postoperative pulmonary impairment is common in the early period after coronary artery bypass grafting (CABG) and noninvasive ventilation (NIV) has been used in postoperative care to prevent and treatment. Recruitment maneuver (RM) consists in a sustained raise of airway pressure with high levei of positive end-expiratory pressure (PEEP) in hypoxemic subjects, insuring a homogeneous pulmonary ventilation and enhancing oxygenation. The aims of this study were to evaluate if the use of NIV associated with RM could improve oxygenation and if it could be safely applied in CABG postoperative patients. METHODS: Were included 34 patients admitled to the intensive care unit (ICU) mechanically ventilated after CABG with Pa02/Fi02 ratio < 300 and radiological atelectasis score (RAS) ~ 2. Patients were randomized 16 to the control group (CG) and 18 to the recruitment group (RG), after extubation NIV was applied for 30 minutes three times a day according to ICU routine. In the CG, NIV was performed with PEEP 8 cm H20 and in the RG, was applied PEEP 15 cm H20 and 20 cm H20 for 2 minutes each and then was with PEEP 8 cm H20. We analyzed Pa02 from arterial blood gas at room air and RAS, hemodynamic stability and adverse event until discharged from the ICU. RESUL TS: Increased of Pa02 12.6±6.8% CG and 23.3±8.5% RG p < 0,001, RAS presented complete improvement for 94.4% RG, whereas in the CG, 87.5% presented some degree of atelectasis, p < 0,001. There was no adverse event related. CONCLUSION: The use of 30 minutes of NIV associated with RM was safe, improved oxygenation and reduced atelectasis

Page generated in 0.0761 seconds