• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 4
  • 1
  • 1
  • Tagged with
  • 11
  • 11
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utility of bispectral index (BIS) monitoring during general anesthesia

Lindholm, Maj-Lis, January 2009 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2009.
2

Evaluation of a laser doppler system for myocardial perfusion monitoring /

Fors, Carina, January 2007 (has links)
Licentiatavhandling (sammanfattning) Linköping : Linköpings universitet, 2007. / Härtill 3 uppsatser.
3

Hypnosis monitoring during general anaesthesia : with focus on awareness /

Ekman, Andreas, January 2007 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2007. / Härtill 4 uppsatser.
4

Klinička procena neuromišićne blokade intraoperativnim neurofiziološkim monitoringom / Clinical determination of neuromuscular blockade by intraoperative neurophysiologic monitoring

Gavrančić Brane 11 December 2014 (has links)
<p>Ciljevi: U kliničkoj praksi se rutinski upotrebljava vizuelna metoda evaluacije TOF testa, koja ne pruža u potpunosti precizne podatke u periodu oporavka neuromi&scaron;ićne blockade. Neophodno je ispitati mogućnost upotrebe specifičnije i preciznije metode u TOF monitoring, kao &scaron;to je kvantitativna TOF metoda. Određivanje razlike između vrednosti T1 i T4 mi&scaron;ićnih kontrakcija, dobijenih kvantitativnom TOF metodom, može biti precizan pokazatelj prisustva neuromi&scaron;ićne blokade na testiranom mi&scaron;iću. Takođe, aplikacijom kvantitativne TOF metode, neophodno je utvrditi da li kod različitih mi&scaron;ića postoji različit period oporavka od prisustva neuromi&scaron;ićne blokade. Upotreba kvantitativne TOF metode, i poređenje T4 / T1 odnosa između različitih mi&scaron;ića, može biti pokazatelj postojanja razlika u oporavku od prisustva neuromi&scaron;ićne blokade. Materijal i metode: U istraživanju je analiziran oporavak od prisustva neromi&scaron;ićne blokade na m.abductor hallucis i m. interosseus dorsalis primus aplikacijom kvantitativnog TOF testa u toku ortopedskih hirur&scaron;kih procedura na kičmenom stubu uz upotrebu intraoperativnog neurofiziolo&scaron;kog monitoring kod 147 bolesnika. T4/T1 odnos je određen na testiranom mi&scaron;iću stopala i &scaron;ake, obavljena je klasifikacija ispitanika u odnosu na dozu neuromi&scaron;ićnog blokatora i proteklo vreme od apilikacije. Poređenjem T4/T1 odnosa između testiranih mi&scaron;ića utvrđene su razlike u oporavku od prisustva neuromi&scaron;ićne blokade. Vizuelnom TOF metodom je vr&scaron;ena procena neuromi&scaron;ićne blokade od strane anesteziologa, stimulacijom n.ulnaris i praćenjem kontrakcije m.adductor pollicis. Rezultati dobijeni vizuelnom TOF metodom su upoređeni sa rezultatima dobijenim kvantitativnom TOF metodom na m. interosseus dorsalis primus. Rezultati: Postoje značajne razlike u T4/T1 odnosu između testiranih mi&scaron;ića na stopalu i &scaron;aci (p&lt;0.05). T4/T1 odnos određen na m.abductor hallucis ima niže vrednosti, odnosno brži oporavak, u odnosu na m. interosseus dorsalis primus (p&lt;0.05). Kvantitativnom TOF metodom dobijeni su pouzdani rezultati o proceni neuromi&scaron;ićne blokade kod svih testiranih bolesnika, dok su vizuelnom TOF metodom dobijeni kod 40 % testiranih bolesnika. Rezultati pokazuju da postoje značajne razlike u pouzdanosti i preciznosti između kvantitativne i vizuelne TOF metode. Zaključak: Kvantitativna TOF metoda je klinički prihvatljiva i pouzdana metoda u proceni prisustva neuromi&scaron;ićne blokade. Razlike u oporavku od neuromi&scaron;ićne blokade uočene kod različitih mi&scaron;ića, ukazuju da je TOF monitoring neophodan na određenoj mi&scaron;ićnoj regiji koja pruža pouzdane i precizne podatke o neuromi&scaron;ićnoj blokadi regije na kojoj se hirur&scaron;ka procedura obavlja. Kvantitativna TOF metoda pruža preciznije podatke o stepenu prisustva neuromi&scaron;ićne blokade u odnosu na vizuelnu subjektivnu TOF metodu.</p> / <p>Purpose: In clinical practice routinely used method of TOF test is visual method of interpretation. This method does not provide completely reliable data in period of spontaneous recovery from neuromuscular blockade. It is necessary to investigate possibility of application of more specific and more accurate method in TOF monitoring, such as quantitative TOF method. Determination of difference between the values of T1 and T4 muscle contraction, obtained by quantitative TOF method, may indicate the presence of neuromuscular blockade on tested muscle. In addition to this, by application of quantitative TOF method, it is necessary to determine is there a difference in period of recovery from neuromuscular blockade between defferent muscles. Comparison of T4/T1 ratios between different muscles may indicate presence of different period of recovery from neuromuscular blockade. Methods: Study analyzed differences between recovery of foot - abductor hallucis muscle and hand - first dorsal interosseous muscle by application of quantitative TOF test on 147 patients undergoing lumbar spine surgery. T1 to T4 decrements on hand and foot TOF were determined and classified into different groups, depending of neuromuscular blocking agents (NMBA) dose and elapsed time after administration. T1 - T4 decrements were compared between hand and foot TOF and differences between muscle recovery were determined. Visual method of TOF test was performed by anesthesiologists, by using peripheral nerve stimulator and stimulating ulnar nerve. Quantitative TOF test was measured on first dorsal interosseous muscle, and compared with visual TOF results obtained on adductor pollicis muscle. Results: There are significant differences between T1 - T4 decrements obtained on tested muscles of hand and foot (p&lt;0.05). T1-T4 decrement determined on abductor hallucis muscle had lower values, respectively more rapid recovery, than first dorsal interosseous muscle (p&lt;0.05). Quantitative method of TOF test had reliable and correct results in all tested subjects, while visual interpretation of TOF method showed accurate results in 40 % of all cases. Results indicated that significant difference was present between quantitative and visual method of TOF interpretation. Conclusions: Difference between observed recovery of hand and foot muscles is indicating that quantitative TOF test should be performed on specific site for which accurate data about the level of neuromuscular blockade is needed. During lumbar spine surgery, in addition to hand TOF, foot TOF should be included as it provides more accurate data needed for neurophysiological intraoperative monitoring. Quantitative TOF method provides more accurate data about level of neuromuscular blockade if compared with subjective visual TOF method.</p>
5

Análise crítica do decaimento no nível do paratormônio intra-operatório para prognóstico de sucesso da paratireoidectomia no controle precoce do hiperparatireoidismo secundário e terciário / Critical analysis of the decrease in the level of intraoperative parathyroid hormone for the prognosis of successful parathyroidectomy in the early control of secondary and tertiary hyperparathyroidism

Silveira, André Albuquerque 12 December 2018 (has links)
INTRODUÇÃO: A monitorização do paratormônio rápido (PTHr) é padrão no tratamento cirúrgico do hiperparatireoidismo primário, para garantir a retirada da paratireoide doente e preservação das saudáveis. Sua utilidade no tratamento cirúrgico do hiperparatireoidismo secundário à doença renal crônica é controversa. Esse estudo tem como objetivo verificar: 1) se a medida PTHr auxilia na predição do resultado cirúrgico precoce; 2) se existem diferenças de comportamento do PTHr entre pacientes dialíticos e transplantados; 3) se existem diferenças de comportamento do PTHr entre modalidades de operações distintas; 4) a acurácia do método em predizer controle do hiperparatireoidismo renal. MÉTODOS: Trata-se de estudo de coorte retrospectiva e prospectiva observacional, de pacientes com diagnóstico de HPTr, dialítico ou persistência após transplante renal, submetidos a paratireoidectomia total ou subtotal em único centro, no período de 2011 a 2016. Durante a cirurgia, realizamos coletas seriadas do PTHr, sendo três dessas amostras antes da exérese das glândulas paratireoides (basal periférico, basal central e pré-retirada), e duas após ressecção (10 min e 15 min). O critério de queda porcentual igual ou maior a 80% do maior valor entre as amostras basais, em 10 minutos, foi arbitrado preditor de êxito intra-operatório. Os pacientes foram seguidos durante intervalos regulares (15 dias, 3, 6 e 12 meses). Foram divididos em dois grupos (sucesso e falha da operação) de acordo com o controle dos níveis de PTH, cálcio e fósforo conforme consensos internacionais, ao término do seguimento de 1 ano. RESULTADOS: Duzentos e vinte e oito pacientes foram elegíveis, sendo 186 (81,6%) dialíticos e 42 (18,4%) transplantados. A paratireoidectomia alcançou sucesso em 92,1% (210/228) e falha em 7,9% (18/228) dos pacientes, sem diferenças de resultados entre grupos de diagnósticos diferentes e/ou tipos de operações distintas. O principal motivo de falha foi presença de glândula supranumerária, em 61,1% dos casos (11/18). A amostra basal central (BC) representou o real maior valor basal do PTHr para ambos os diagnósticos, porém com maior chance de picos do PTHr na amostra pré-retirada (PRE) nos pacientes transplantados. Após remoção da massa de tecido paratireóideo doente, os níveis de PTHr foram menores em 10 minutos quando comparados com as amostras basais (resultado estatisticamente significativo) para todos diagnósticos, tipos de operações e desfechos terapêuticos. No grupo sucesso, houve diferença estatisticamente significativa, entre as medidas de 10 e 15 minutos entre si, com valores menores em 15 minutos, enquanto que no grupo falha, sem distinção de 10 e 15 minutos entre si e com valores médios maiores em 15 min. Os valores do PTHr foram maiores no paciente dialítico quando comparados com transplantado, em todas as amostras (p < 0,001). No grupo sucesso, os pacientes dialíticos e transplantados, e os pacientes dialíticos submetidos a exérese total e subtotal apresentaram porcentual de queda do PTHr semelhantes em 10 e 15 minutos para as amostras BC e PRE; o paciente transplantado obteve decaimentos porcentuais menores quando houve ressecção subtotal. O grupo falha apresentou queda porcentual nitidamente menor e com significância estatística (p < 0,001), para todas amostra basais e em qualquer momento, quando comparado ao grupo sucesso. A função renal pré-operatória dos transplantados não influenciou a cinética de decaimento do PTHr (não teve correlação, p=0,09). A monitorização do PTHr influenciou a conduta cirúrgica em 7% (16/228) da casuística; o principal motivo foi a ocorrência de localização ectópica de umas das quatros paratireoides, responsável por 75% (12/16) dos casos. A paratireiodectomia bem sucedida exibiu impacto negativo na função do enxerto renal no pós-operatório, porém com posterior recuperação ao término de 1 ano. O método da dosagem do PTHr com o critério de 80% de queda, apresentou acurácia de 87%, sensibilidade de 88% e especificidade de 67% para a amostra BC em 15 minutos, e melhor especificidade (74%) na amostra PRE em 10 min. CONCLUSÕES: Em pacientes com hiperparatireoidismo renal, uso de medidas intra-operatórias do PTHr apresenta alta sensibilidade para indicar o sucesso da operação quando há redução de 80% dos valores iniciais. Apesar de valores absolutos diferentes, as taxas de redução desse hormônio após uma paratireoidectomia bem sucedida não são significativamente diferentes em pacientes dialíticos e transplantados, em operação total com auto-enxerto ou subtotal, com efetiva queda em 10 minutos de amostragem. A utilização de uma medida adicional 15 minutos após a retirada das glândulas aumenta a acurácia do método. A medida intra-operatória do PTHr pode auxiliar na tomada de decisões durante a operação desses pacientes / INTRODUCTION: Rapid Parathyroid Monitoring (rPTH) is standard in the surgical treatment of primary hyperparathyroidism, to ensure the excision of the diseased parathyroid and preservation of healthy parathyroid glands. Its usefulness in the surgical treatment of hyperparathyroidism secondary to chronic kidney disease is controversial. This study aims to verify: 1) whether the rPTH measure assists in the prediction of the early surgical outcome; 2) whether there are differences in rPTH pattern between dialytic and transplanted patients; 3) if there are differences in the decay of the rPTH between different operations modalities; 4) the accuracy of the method in predicting control of renal hyperparathyroidism. METHODS: This is a retrospective and prospective observational cohort study of patients with a diagnosis of PTH, dialysis or persistence after renal transplantation, who underwent total or subtotal parathyroidectomy in a single center from 2011 to 2016. During surgery, we performed serial samples of the rPTH, three of these were before excision of the parathyroid glands (peripheral basal, central basal and pre-withdrawal), and two after resection (10 min and 15 min). The criterion of percentage drop equal to or greater than 80% of the highest value of the basal samples, in 10 minutes, was arbitrated predictor of intraoperative success. Patients were followed at regular intervals (15 days, 3, 6 and 12 months). They were divided into two groups (success and failure of the operation) according to the control of the levels of PTH, calcium and phosphorus according to international consensus, at the end of the 1 year follow-up. RESULTS: Two hundred and twenty-eight patients were eligible, being 186 (81.6%) dialytic and 42 (18.4%) transplanted. Parathyroidectomy achieved success in 92.1% (210/228) and failure in 7.9% (18/228) of the patients, with no differences in results between groups of different diagnoses and/or different types of operations. The main reason for failure was the presence of supernumerary glands, 61.1% of the cases (11/18). The central basal (CB) sample represented the actual higher baseline PTHr for both diagnoses, but with a higher chance of rPTH peaks in the pre-withdrawal sample (PRE) in the transplanted patients. After removal of the diseased parathyroid tissue mass, rPTH levels were lower in 10 minutes compared to baseline (statistically significant) for all diagnoses, types of operations and therapeutic outcomes. In the success group, there was a statistically significant difference between the 10 and 15 minutes measurements, with smaller values in 15 minutes, while in the failure group, there was no distinction of 10 and 15 minutes between them and with mean values greater in 15 min. The rPTH values were higher in the dialytic patient when compared to transplanted in all samples (p < 0.001). In the success group, dialytic and transplanted patients, and dialytic patients submitted to total and subtotal excision, presented similar percent drop in rPTH at 10 and 15 minutes for CB and PRE samples; the transplanted patient had lower percentage decreases when subtotal resection. The failure group had a significantly lower percentage drop and with statistical significance (p < 0.001), for all baseline and at any time, when compared to the success group. The preoperative renal function of the transplanted patients did not influence the kinetics of rPTH decay (had no correlation, p=0.09). The rPTH monitoring influenced the surgical management in 7% (16/228) of the series; the main reason was the occurrence of ectopic localization of one of the four parathyroid glands, responsible for 75% (12/16) of the cases. In transplanted patients, successful parathyroidectomy had a negative impact on renal graft function in the postoperative period, but with a subsequent recovery at the end of 1 year. The rPTH dosage method with the 80% drop criterion showed an accuracy of 87%, a sensitivity of 88% and specificity of 67% for the CB sample in 15 minutes and a better specificity (74%) in the PRE sample in 10 min. CONCLUSION: In patients with renal hyperparathyroidism, the use of intraoperative measurements of rPTH has a high sensitivity to indicate the success of the operation when there is a reduction of 80% of the initial values. In spite of different absolute values, the rates of reduction of this hormone after successful parathyroidectomy are not significantly different in dialytic and transplant patients, in total autograft or subtotal operation, with an effective drop in 10 minutes of sampling. The use of an additional measurement 15 minutes after removal of the glands increases the accuracy of the method. The intraoperative measurement of rPTH may aid in decision making during the operation of these patients
6

Avaliação hemodinâmica durante a revascularização do miocárdio sem utilização de circulação extracorpórea / Hemodynamic evaluation during off-pump coronary artery bypass surgery

Kim, Silvia Minhye 23 April 2008 (has links)
INTRODUÇÃO: A cirurgia de revascularização miocárdica sem utilização de circulação extracorpórea (CEC) tem sido cada vez mais utilizada, especialmente após a introdução de dispositivos estabilizadores da parede cardíaca. Entretanto, a técnica pode causar alterações hemodinâmicas durante a realização das anastomoses coronárias. OBJETIVOS: Analisar as alterações hemodinâmicas decorrentes das mudanças de posição do coração para abordar as artérias coronárias sem CEC e comparar os monitores de débito cardíaco semi-contínuo e de ecodoppler transesofágico quanto à precisão das medidas hemodinâmicas. MATERIAL E MÉTODOS: Foram selecionados aleatoriamente 20 pacientes adultos com idade inferior a 80 anos, candidatos a cirurgia eletiva de revascularização miocárdica sem utilização de circulação extracorpórea. A avaliação hemodinâmica incluiu a utilização de ecodopppler com transdutor esofágico e de cateter de artéria pulmonar com filamento térmico. A coleta de dados foi realizada: 1 - após a indução da anestesia, antes do início da revascularização propriamente dita, 2 - durante a realização das anastomoses distais, logo após o posicionamento e estabilização do coração e 3 - após cinco minutos do início da anastomose. Os dados hemodinâmicos foram analisados por análise de variância de duplo fator com repetição, complementada por teste de Newman-Keuls. O nível de significância considerado foi de 5%. Os valores de débito cardíaco foram comparados segundo método proposto por Bland e Altman, analisando a correlação intraclasses, diferenças médias e intervalos de confiança de 95%. RESULTADOS: Alterações hemodinâmicas significativas foram detectadas para o aumento de pressão de oclusão de artéria pulmonar (de 17,7 ± 6,1 para 19,2 ± 6,5 mmHg - p<0,001 e para 19,4 ± 5,8 mmHg - p<0,001) e pressão venosa central (de 13,9 ± 5,4 para 14,9 ± 5,9 mmHg - p=0,007 e para 15,1 ± 6,0 mmHg - p=0,006), além de diminuição do débito cardíaco obtido por termodiluição intermitente (de 4,70 ± 1,43 para 4,23 ± 1,22 L/min - p<0,001 e para 4,26 ± 1,27 L/min - p<0,001). Houve interação grupo-tempo estatisticamente significativa no débito cardíaco por Doppler esofágico, que apresentou redução no grupo lateral de 4,08 ± 1,99 para 2,84 ± 1,81 L/min (p=0,02) e para 2,86 ± 1,73 L/min (p=0,02), e no fluxo sanguíneo aórtico, que diminuiu de 2,85 ± 1,39 para 1,99 ± 1,26 L/min (p=0,02) e para 2,00 ± 1,21 L/min (p=0,02). As medidas de débito cardíaco intermitente, semicontínuo e por Doppler esofágico apresentaram diferenças médias e intervalos de confiança de 95% acima de limites aceitáveis clinicamente. CONCLUSÕES: Houve deterioração hemodinâmica significativa durante a revascularização miocárdica sem CEC. Pelo Doppler esofágico, o débito cardíaco apresentou redução detectada apenas na parede lateral. As diferenças nos valores de débito cardíaco foram muito amplas para considerar os métodos concordantes, em quaisquer das condições hemodinâmicas estudadas. / INTRODUCTION: Coronary artery bypass graft (CABG) surgeries have been performed increasingly without cardiopulmonary bypass (off-pump CABG), specially with introduction of cardiac wall stabilizing devices. However, hemodynamic changes can occur during coronary anastomosis. OBJECTIVES: To study hemodynamic alterations caused when cardiac position is changed to operate coronary arteries and to compare continuous cardiac output and esophageal Doppler monitor regardig accuracy of hemodynamic measurements. MATERIALS AND METHODS: Twenty adult patients under age of 80 undergoing elective off-pump CABG were enrolled. Hemodynamic evaluation was performed with esophageal echodoppler and continuous thermodilution pulmonary artery catheter. Data were collected 1 - after induction of anesthesia, before revascularization, 2 - during distal anastomosis, right after heart positioning and stabilization, and 3 - five minutes following the beginning of anastomosis. Repeated measures two-way ANOVA with post hoc Newman-Keuls tests were used to analyse hemodynamic data and level of significance was set at 0.05. Cardiac output values were compared using the method proposed by Bland and Altman, and included analysis of correlation, mean differences and 95% confidence intervals. RESULTS: Significant hemodynamic alterations were detected during revascularization of coronary arteries as elevation of pulmonary artery occlusion pressure (from 17.7 ± 6.1 to 19.2 ± 6.5 mmHg - P <0.001, and to 19.4 ± 5.8 mmHg - P <0.001) and of central venous pressures (from 13.9 ± 5.4 to 14.9 ± 5.9 mmHg - P =0.007, and to 15.1 ± 6.0 mmHg - P =0.006), and as reduction of intermittent cardiac output (from 4.70 ± 1.43 to 4.23 ± 1.22 l/min - P <0.001, and to 4.26 ± 1.27 l/min - P <0.001). Statistically significant group-time interaction was observed in esophageal Doppler cardiac output, that decreased in the lateral wall from 4.08 ± 1.99 to 2.84 ± 1.81 l/min (P =0.02) and to 2.86 ± 1.73 l/min (P =0.02), and in aortic blood flow, that decreased from 2.85 ± 1.39 to 1.99 ± 1.26 l/min (P =0,02) and to 2.00 ± 1.21 l/min (P =0.02). Intermittent, STAT-mode or esophageal Doppler cardiac output mean differences and 95% confidence intervals were beyond clinically acceptable limits. CONCLUSIONS: There was significant hemodynamic deterioration during off-pump CABG. On the esophageal Doppler monitor, cardiac output decrease was detected only in the lateral wall. Differences in cardiac output measurements were too wide to say methods agreed, in all hemodynamic conditions studied.
7

Análise crítica do decaimento no nível do paratormônio intra-operatório para prognóstico de sucesso da paratireoidectomia no controle precoce do hiperparatireoidismo secundário e terciário / Critical analysis of the decrease in the level of intraoperative parathyroid hormone for the prognosis of successful parathyroidectomy in the early control of secondary and tertiary hyperparathyroidism

André Albuquerque Silveira 12 December 2018 (has links)
INTRODUÇÃO: A monitorização do paratormônio rápido (PTHr) é padrão no tratamento cirúrgico do hiperparatireoidismo primário, para garantir a retirada da paratireoide doente e preservação das saudáveis. Sua utilidade no tratamento cirúrgico do hiperparatireoidismo secundário à doença renal crônica é controversa. Esse estudo tem como objetivo verificar: 1) se a medida PTHr auxilia na predição do resultado cirúrgico precoce; 2) se existem diferenças de comportamento do PTHr entre pacientes dialíticos e transplantados; 3) se existem diferenças de comportamento do PTHr entre modalidades de operações distintas; 4) a acurácia do método em predizer controle do hiperparatireoidismo renal. MÉTODOS: Trata-se de estudo de coorte retrospectiva e prospectiva observacional, de pacientes com diagnóstico de HPTr, dialítico ou persistência após transplante renal, submetidos a paratireoidectomia total ou subtotal em único centro, no período de 2011 a 2016. Durante a cirurgia, realizamos coletas seriadas do PTHr, sendo três dessas amostras antes da exérese das glândulas paratireoides (basal periférico, basal central e pré-retirada), e duas após ressecção (10 min e 15 min). O critério de queda porcentual igual ou maior a 80% do maior valor entre as amostras basais, em 10 minutos, foi arbitrado preditor de êxito intra-operatório. Os pacientes foram seguidos durante intervalos regulares (15 dias, 3, 6 e 12 meses). Foram divididos em dois grupos (sucesso e falha da operação) de acordo com o controle dos níveis de PTH, cálcio e fósforo conforme consensos internacionais, ao término do seguimento de 1 ano. RESULTADOS: Duzentos e vinte e oito pacientes foram elegíveis, sendo 186 (81,6%) dialíticos e 42 (18,4%) transplantados. A paratireoidectomia alcançou sucesso em 92,1% (210/228) e falha em 7,9% (18/228) dos pacientes, sem diferenças de resultados entre grupos de diagnósticos diferentes e/ou tipos de operações distintas. O principal motivo de falha foi presença de glândula supranumerária, em 61,1% dos casos (11/18). A amostra basal central (BC) representou o real maior valor basal do PTHr para ambos os diagnósticos, porém com maior chance de picos do PTHr na amostra pré-retirada (PRE) nos pacientes transplantados. Após remoção da massa de tecido paratireóideo doente, os níveis de PTHr foram menores em 10 minutos quando comparados com as amostras basais (resultado estatisticamente significativo) para todos diagnósticos, tipos de operações e desfechos terapêuticos. No grupo sucesso, houve diferença estatisticamente significativa, entre as medidas de 10 e 15 minutos entre si, com valores menores em 15 minutos, enquanto que no grupo falha, sem distinção de 10 e 15 minutos entre si e com valores médios maiores em 15 min. Os valores do PTHr foram maiores no paciente dialítico quando comparados com transplantado, em todas as amostras (p < 0,001). No grupo sucesso, os pacientes dialíticos e transplantados, e os pacientes dialíticos submetidos a exérese total e subtotal apresentaram porcentual de queda do PTHr semelhantes em 10 e 15 minutos para as amostras BC e PRE; o paciente transplantado obteve decaimentos porcentuais menores quando houve ressecção subtotal. O grupo falha apresentou queda porcentual nitidamente menor e com significância estatística (p < 0,001), para todas amostra basais e em qualquer momento, quando comparado ao grupo sucesso. A função renal pré-operatória dos transplantados não influenciou a cinética de decaimento do PTHr (não teve correlação, p=0,09). A monitorização do PTHr influenciou a conduta cirúrgica em 7% (16/228) da casuística; o principal motivo foi a ocorrência de localização ectópica de umas das quatros paratireoides, responsável por 75% (12/16) dos casos. A paratireiodectomia bem sucedida exibiu impacto negativo na função do enxerto renal no pós-operatório, porém com posterior recuperação ao término de 1 ano. O método da dosagem do PTHr com o critério de 80% de queda, apresentou acurácia de 87%, sensibilidade de 88% e especificidade de 67% para a amostra BC em 15 minutos, e melhor especificidade (74%) na amostra PRE em 10 min. CONCLUSÕES: Em pacientes com hiperparatireoidismo renal, uso de medidas intra-operatórias do PTHr apresenta alta sensibilidade para indicar o sucesso da operação quando há redução de 80% dos valores iniciais. Apesar de valores absolutos diferentes, as taxas de redução desse hormônio após uma paratireoidectomia bem sucedida não são significativamente diferentes em pacientes dialíticos e transplantados, em operação total com auto-enxerto ou subtotal, com efetiva queda em 10 minutos de amostragem. A utilização de uma medida adicional 15 minutos após a retirada das glândulas aumenta a acurácia do método. A medida intra-operatória do PTHr pode auxiliar na tomada de decisões durante a operação desses pacientes / INTRODUCTION: Rapid Parathyroid Monitoring (rPTH) is standard in the surgical treatment of primary hyperparathyroidism, to ensure the excision of the diseased parathyroid and preservation of healthy parathyroid glands. Its usefulness in the surgical treatment of hyperparathyroidism secondary to chronic kidney disease is controversial. This study aims to verify: 1) whether the rPTH measure assists in the prediction of the early surgical outcome; 2) whether there are differences in rPTH pattern between dialytic and transplanted patients; 3) if there are differences in the decay of the rPTH between different operations modalities; 4) the accuracy of the method in predicting control of renal hyperparathyroidism. METHODS: This is a retrospective and prospective observational cohort study of patients with a diagnosis of PTH, dialysis or persistence after renal transplantation, who underwent total or subtotal parathyroidectomy in a single center from 2011 to 2016. During surgery, we performed serial samples of the rPTH, three of these were before excision of the parathyroid glands (peripheral basal, central basal and pre-withdrawal), and two after resection (10 min and 15 min). The criterion of percentage drop equal to or greater than 80% of the highest value of the basal samples, in 10 minutes, was arbitrated predictor of intraoperative success. Patients were followed at regular intervals (15 days, 3, 6 and 12 months). They were divided into two groups (success and failure of the operation) according to the control of the levels of PTH, calcium and phosphorus according to international consensus, at the end of the 1 year follow-up. RESULTS: Two hundred and twenty-eight patients were eligible, being 186 (81.6%) dialytic and 42 (18.4%) transplanted. Parathyroidectomy achieved success in 92.1% (210/228) and failure in 7.9% (18/228) of the patients, with no differences in results between groups of different diagnoses and/or different types of operations. The main reason for failure was the presence of supernumerary glands, 61.1% of the cases (11/18). The central basal (CB) sample represented the actual higher baseline PTHr for both diagnoses, but with a higher chance of rPTH peaks in the pre-withdrawal sample (PRE) in the transplanted patients. After removal of the diseased parathyroid tissue mass, rPTH levels were lower in 10 minutes compared to baseline (statistically significant) for all diagnoses, types of operations and therapeutic outcomes. In the success group, there was a statistically significant difference between the 10 and 15 minutes measurements, with smaller values in 15 minutes, while in the failure group, there was no distinction of 10 and 15 minutes between them and with mean values greater in 15 min. The rPTH values were higher in the dialytic patient when compared to transplanted in all samples (p < 0.001). In the success group, dialytic and transplanted patients, and dialytic patients submitted to total and subtotal excision, presented similar percent drop in rPTH at 10 and 15 minutes for CB and PRE samples; the transplanted patient had lower percentage decreases when subtotal resection. The failure group had a significantly lower percentage drop and with statistical significance (p < 0.001), for all baseline and at any time, when compared to the success group. The preoperative renal function of the transplanted patients did not influence the kinetics of rPTH decay (had no correlation, p=0.09). The rPTH monitoring influenced the surgical management in 7% (16/228) of the series; the main reason was the occurrence of ectopic localization of one of the four parathyroid glands, responsible for 75% (12/16) of the cases. In transplanted patients, successful parathyroidectomy had a negative impact on renal graft function in the postoperative period, but with a subsequent recovery at the end of 1 year. The rPTH dosage method with the 80% drop criterion showed an accuracy of 87%, a sensitivity of 88% and specificity of 67% for the CB sample in 15 minutes and a better specificity (74%) in the PRE sample in 10 min. CONCLUSION: In patients with renal hyperparathyroidism, the use of intraoperative measurements of rPTH has a high sensitivity to indicate the success of the operation when there is a reduction of 80% of the initial values. In spite of different absolute values, the rates of reduction of this hormone after successful parathyroidectomy are not significantly different in dialytic and transplant patients, in total autograft or subtotal operation, with an effective drop in 10 minutes of sampling. The use of an additional measurement 15 minutes after removal of the glands increases the accuracy of the method. The intraoperative measurement of rPTH may aid in decision making during the operation of these patients
8

Avaliação hemodinâmica durante a revascularização do miocárdio sem utilização de circulação extracorpórea / Hemodynamic evaluation during off-pump coronary artery bypass surgery

Silvia Minhye Kim 23 April 2008 (has links)
INTRODUÇÃO: A cirurgia de revascularização miocárdica sem utilização de circulação extracorpórea (CEC) tem sido cada vez mais utilizada, especialmente após a introdução de dispositivos estabilizadores da parede cardíaca. Entretanto, a técnica pode causar alterações hemodinâmicas durante a realização das anastomoses coronárias. OBJETIVOS: Analisar as alterações hemodinâmicas decorrentes das mudanças de posição do coração para abordar as artérias coronárias sem CEC e comparar os monitores de débito cardíaco semi-contínuo e de ecodoppler transesofágico quanto à precisão das medidas hemodinâmicas. MATERIAL E MÉTODOS: Foram selecionados aleatoriamente 20 pacientes adultos com idade inferior a 80 anos, candidatos a cirurgia eletiva de revascularização miocárdica sem utilização de circulação extracorpórea. A avaliação hemodinâmica incluiu a utilização de ecodopppler com transdutor esofágico e de cateter de artéria pulmonar com filamento térmico. A coleta de dados foi realizada: 1 - após a indução da anestesia, antes do início da revascularização propriamente dita, 2 - durante a realização das anastomoses distais, logo após o posicionamento e estabilização do coração e 3 - após cinco minutos do início da anastomose. Os dados hemodinâmicos foram analisados por análise de variância de duplo fator com repetição, complementada por teste de Newman-Keuls. O nível de significância considerado foi de 5%. Os valores de débito cardíaco foram comparados segundo método proposto por Bland e Altman, analisando a correlação intraclasses, diferenças médias e intervalos de confiança de 95%. RESULTADOS: Alterações hemodinâmicas significativas foram detectadas para o aumento de pressão de oclusão de artéria pulmonar (de 17,7 ± 6,1 para 19,2 ± 6,5 mmHg - p<0,001 e para 19,4 ± 5,8 mmHg - p<0,001) e pressão venosa central (de 13,9 ± 5,4 para 14,9 ± 5,9 mmHg - p=0,007 e para 15,1 ± 6,0 mmHg - p=0,006), além de diminuição do débito cardíaco obtido por termodiluição intermitente (de 4,70 ± 1,43 para 4,23 ± 1,22 L/min - p<0,001 e para 4,26 ± 1,27 L/min - p<0,001). Houve interação grupo-tempo estatisticamente significativa no débito cardíaco por Doppler esofágico, que apresentou redução no grupo lateral de 4,08 ± 1,99 para 2,84 ± 1,81 L/min (p=0,02) e para 2,86 ± 1,73 L/min (p=0,02), e no fluxo sanguíneo aórtico, que diminuiu de 2,85 ± 1,39 para 1,99 ± 1,26 L/min (p=0,02) e para 2,00 ± 1,21 L/min (p=0,02). As medidas de débito cardíaco intermitente, semicontínuo e por Doppler esofágico apresentaram diferenças médias e intervalos de confiança de 95% acima de limites aceitáveis clinicamente. CONCLUSÕES: Houve deterioração hemodinâmica significativa durante a revascularização miocárdica sem CEC. Pelo Doppler esofágico, o débito cardíaco apresentou redução detectada apenas na parede lateral. As diferenças nos valores de débito cardíaco foram muito amplas para considerar os métodos concordantes, em quaisquer das condições hemodinâmicas estudadas. / INTRODUCTION: Coronary artery bypass graft (CABG) surgeries have been performed increasingly without cardiopulmonary bypass (off-pump CABG), specially with introduction of cardiac wall stabilizing devices. However, hemodynamic changes can occur during coronary anastomosis. OBJECTIVES: To study hemodynamic alterations caused when cardiac position is changed to operate coronary arteries and to compare continuous cardiac output and esophageal Doppler monitor regardig accuracy of hemodynamic measurements. MATERIALS AND METHODS: Twenty adult patients under age of 80 undergoing elective off-pump CABG were enrolled. Hemodynamic evaluation was performed with esophageal echodoppler and continuous thermodilution pulmonary artery catheter. Data were collected 1 - after induction of anesthesia, before revascularization, 2 - during distal anastomosis, right after heart positioning and stabilization, and 3 - five minutes following the beginning of anastomosis. Repeated measures two-way ANOVA with post hoc Newman-Keuls tests were used to analyse hemodynamic data and level of significance was set at 0.05. Cardiac output values were compared using the method proposed by Bland and Altman, and included analysis of correlation, mean differences and 95% confidence intervals. RESULTS: Significant hemodynamic alterations were detected during revascularization of coronary arteries as elevation of pulmonary artery occlusion pressure (from 17.7 ± 6.1 to 19.2 ± 6.5 mmHg - P <0.001, and to 19.4 ± 5.8 mmHg - P <0.001) and of central venous pressures (from 13.9 ± 5.4 to 14.9 ± 5.9 mmHg - P =0.007, and to 15.1 ± 6.0 mmHg - P =0.006), and as reduction of intermittent cardiac output (from 4.70 ± 1.43 to 4.23 ± 1.22 l/min - P <0.001, and to 4.26 ± 1.27 l/min - P <0.001). Statistically significant group-time interaction was observed in esophageal Doppler cardiac output, that decreased in the lateral wall from 4.08 ± 1.99 to 2.84 ± 1.81 l/min (P =0.02) and to 2.86 ± 1.73 l/min (P =0.02), and in aortic blood flow, that decreased from 2.85 ± 1.39 to 1.99 ± 1.26 l/min (P =0,02) and to 2.00 ± 1.21 l/min (P =0.02). Intermittent, STAT-mode or esophageal Doppler cardiac output mean differences and 95% confidence intervals were beyond clinically acceptable limits. CONCLUSIONS: There was significant hemodynamic deterioration during off-pump CABG. On the esophageal Doppler monitor, cardiac output decrease was detected only in the lateral wall. Differences in cardiac output measurements were too wide to say methods agreed, in all hemodynamic conditions studied.
9

Ultrassonografia durante cirurgia para metástase cerebral: influência no índice de Karnofsky e volume do tumor residual / Ultrasonography during surgery to treat cerebral metastases: influence on Karnofsky index score and residual tumor volume

Oliveira, Marcelo de Lima 30 May 2016 (has links)
Introdução: Os principais objetivos do tratamento das metástases cerebrais (MC) são no auxílio do controle da doença no encéfalo e a melhora da qualidade de vida dos pacientes. A cirurgia convencional tem um importante papel no tratamento das MCs e os métodos de monitoração intraoperatória podem auxiliar na obtenção de resultados cirúrgicos melhores. Objetivos: Avaliar a influência da ultrassonografia encefálica durante cirurgia para ressecção de MC no índice de Karnofsky e no grau de ressecção do tumor. Métodos: Neste estudo prospectivo controlado e não randomizado, doentes com indicação de tratamento cirúrgico de MCs foram incluídos. A ultrassonografia intraoperatória (USIO) foi realizada por um neurossonologista. O índice de Karnofsky foi avaliado por equipe multidisciplinar de oncologia; o grau de dificuldade para ressecção cirúrgica do tumor foi avaliado pelo cirurgião e o volume tumoral foi avaliado pelo neurorradiologista por meio da RM realizada no pré e pós-operatório. Resultados: Dos 78 doentes, 40 homens e 38 mulheres com idade média de 53 anos, 35 foram submetidos a tratamento cirúrgico com auxílio da USIO. Não houve diferença estatística no KPS e volume tumoral pré-operatório entre os grupos. O KPS pós-operatório no grupo da USIO foi de 80 e no grupo-controle de 70 (p=0,045). Considerando-se a melhora do KPS no pós-operatório, a quantidade de doentes tiveram melhora do KPS foi superior no grupo da USIO (p=0,036) destacando-se os seguintes subgrupos: tumores com grau de dificuldade de ressecção < 4 (p=0,037), tumores nas áreas eloquentes (p=0,043), tumores não relacionados aos grandes vasos e nervos (p=0,007), e lesões únicas no leito cirúrgico (p=0,038). O tumor residual na RM pós-operatória foi menor no grupo da USIO: 9,5% no grupo da USIO e 30,8% no grupo-controle; 1,6 mm3 no grupo da USIO e 9 mm3 do grupo-controle; p=0,05. Considerando-se doentes com KPS >= 70, o número de doentes com volume de tumor residual inferior a 10% em relação ao volume pré-operatório foi superior no grupo da USIO (p=0,032 e OR de 3,8). Conclusão: Os achados deste estudo sugerem que a USIO encefálica pode influenciar na melhora do índice de Karnofsky e na redução do volume de tumor residual / Object: The goals of treating a cerebral metastasis (CM) are to achieve local control of the disease and to improve patient quality of life. The aim of this study was to analyse the effect of using conventional surgery supported by intra-operative ultrasound (IOUS) to approach a CM. To perform this analysis, we determined Karnofsky post-operative scores (KPS) and tumour resection grades. Methods: Patients with CM who were eligible to undergo a surgical approach were included in this study. Surgical treatment was either supported or not supported by IOUS. A neural oncology team determined the pre- and post-operative KPS. A radiologist examined the tumour volume using pre- and post-operative magnetic resonance imaging. Before the surgery, the surgeon determined whether it was possible to perform a total CM resection. Results: A total of 78 patients with CM diagnosis were treated using a surgical approach (35 with and 43 without IOUS). The post-operative median KPS was higher in the IOUS group (80 versus 70, p=0.045). Within the IOUS group, KPS evolution was superior (p=0.036), especially in the following CM subgroups: a difficulty of tumour resection ranking score<4 (p=0.037), the tumour was in an eloquent area (p=0.043), the tumour was not associated with vessels or nerves (p=0.007), and solitary lesions (p=0.038). The volume of residual tumours was lower in the IOUS group (9.5% and 1.6 mm3 versus 30.8% and 9 mm3, p=0.05). In patients with a KPS >= 70, the residual tumour volume was categorized as < 10% or >= 10%, and 62% of patients had < 10% residual tumours (76% in the IOUS group and 45% in the non-IOUS group; p=0.032 and OR=3.8). Conclusion: This study suggests that IOUS can play a role in improving post-operative KPS and in decreasing residual tumours in CM surgeries
10

The performance of neurophysiologic monitoring to predict postoperative deficits in a porcine model of spinal cord injury. / CUHK electronic theses & dissertations collection

January 2010 (has links)
By observing these warning criteria, surgery can be safely carried out if changes of signal amplitudes are within the threshold boundary. Future studies should aim to validate and refine the "warning criteria" for intraoperative neurophysiologic monitoring in different surgery. / During stable anesthesia, experiments were completed in 31 pigs. A decrease in SEP amplitude > 25% and / or TceMEP amplitude > 65% was associated with substantial risk of postoperative motor deficit. In addition, rapid deterioration of signal within 5 min of an event, and / or a lack of signal recovery within 30 min after the initial deterioration were also predictors of postoperative paraplegia or weakness. These findings also correlated well with radiological changes in the spinal cord. The sensitivity and specificity for TceMEP to predict adverse neurologic outcome were 100% and 90.5%, respectively. / In a porcine model of direct compression and distraction of the exposed spinal cord, we measured the perioperative changes in SEP and TceMEP. This was correlated with postoperative motor function using the modified Tarlov scale. Magnetic resonance diffusion tensor imaging of the spinal cord was also performed to assess the anatomical extent of injury three days after surgery. / The spinal cord is at risk of injury during complex operations of the spine or aorta, and may result in catastrophic long term disability. Intraoperative monitoring with somatosensory evoked potential (SEP) and transcranial electric motor evoked potential (TceMEP) are commonly performed to assess the integrity of the sensory and motor pathways, respectively. The purpose of this study was to identify the minimum changes in signal amplitudes, beyond which postoperative neurologic deficit may occur. / Liu, Quanmeng. / Adviser: Matthew Tu Chan. / Source: Dissertation Abstracts International, Volume: 73-02, Section: B, page: . / Thesis (Ph.D.)--Chinese University of Hong Kong, 2010. / Includes bibliographical references (leaves 87-103). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Electronic reproduction. [Ann Arbor, MI] : ProQuest Information and Learning, [201-] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstract also in Chinese.

Page generated in 0.1874 seconds