FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Estudou-se aqui a viabilidade, sob ponto de vista tÃcnico, da utilizaÃÃo de um efluente de esgoto predominantemente domÃstico oriundo de sistema de tratamento por lagoas de estabilizaÃÃo da ETE da CAGECE, localizada no municÃpio de Aquiraz-CE, como Ãgua de amassamento e cura de concreto produzido em escala laboratorial. Em anÃlise quÃmica preliminar, o efluente analisado mostrou-se adequado à utilizaÃÃo para a produÃÃo de concreto. Os resultados obtidos nos ensaios de determinaÃÃo de pH a 25ÂC, sÃlidos totais, ferro total, cloretos e sulfatos solÃveis mostraram-se dentro dos limites exigidos. NÃo foi constatada diferenÃa significativa entre os resultados obtidos nos ensaios de tempo de pega realizados com pasta de cimento produzida com o efluente analisado e os obtidos com a Ãgua potÃvel, obedecendo ao limite de diferenÃa exigido de 30min. TambÃm nÃo foi constatada diferenÃa significativa entre os resultados obtidos nos ensaios de resistÃncia à compressÃo aos 07 e 28 dias realizados com corpos-de-prova cilÃndricos moldados e curados com o efluente analisado e os obtidos com a Ãgua potÃvel, obedecendo ao limite de diferenÃa exigido de 10%. Embora o efluente tratado tivesse um odor caracterÃstico nÃo muito agradÃvel, a pasta de cimento, o concreto produzido e os corpos-de-prova moldados nÃo sofreram alteraÃÃes perceptÃveis em relaÃÃo ao seu odor. Comprovou-se que, baseado nos requisitos exigidos pela norma NM 137, o efluente de esgoto analisado à adequado para a utilizaÃÃo proposta. / It was studied the feasibility here on a technical point of view, the use of a predominantly domestic sewage effluent comes from the treatment system for stabilising the lagoons of the CAGECEâs Station Treatment of Sewage, located in the city of Aquiraz-CE as moulding and curing water of concrete produced in the laboratory scale. In preliminary chemical analysis, the effluent analysis proved to be suitable for use in the production of concrete. The results for tests to determine the pH to 25ÂC, total solids, total iron, chlorides and sulfates soluble showed itself within the limits required. No significant difference was found between the results in the tests of time to handle with paste made of cement produced with the effluent analysis and those obtained with drinking water, according to the required limit of difference of 30min. Nor was detected significant difference between the results obtained in testing for resistance to compression of 07 and 28 days achieved with corpses-of-proof cylindrical shaped and cured with the effluent analysis and those obtained with drinking water, according to the required limit of difference of 10%. While the treated effluent had a distinctive smell not very pleasant, the portfolio of cement, concrete and produced the bodies proof-of-shaped unchanged against its perceived odor. It has been proved that, based on the standard requirements demanded by NM 137, the sewage effluent is considered appropriate for the proposed use.
Identifer | oai:union.ndltd.org:IBICT/oai:www.teses.ufc.br:1644 |
Date | 07 August 2008 |
Creators | Jorge LuÃs Melo da Silva |
Contributors | Francisco SuetÃnio Bastos Mota, Josà de Paula Barros Neto, Roberto SÃrgio Farias de Souza |
Publisher | Universidade Federal do CearÃ, Programa de PÃs-GraduaÃÃo em Engenharia Civil, UFC, BR |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | application/pdf |
Source | reponame:Biblioteca Digital de Teses e Dissertações da UFC, instname:Universidade Federal do Ceará, instacron:UFC |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0088 seconds