Orientador: Sonia Maria Alves Bueno / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-06T20:08:56Z (GMT). No. of bitstreams: 1
Bresolin_IgorTadeuLazzarotto_M.pdf: 4686617 bytes, checksum: ed7a688421b5d854024279523878c12a (MD5)
Previous issue date: 2006 / Resumo: Anticorpos monoclonais são imunoglobulinas secretadas por clones de linfócitos B, normais, tumorais ou obtidos pela tecnologia de hibridomas. Os anticorpos monoclonais têm sido utilizados nas áreas analítica e terapêutica, o que implica na necessidade de sua obtenção com pureza superior a 95%. Muitos estudos têm sido realizados visando à purificação de anticorpos monoclonais, destacando-se as técnicas de adsorção seletiva, como as cromatografias de troca iônica, hidrofóbica e de afinidade. Neste trabalho aplicou-se a cromatografia de afinidade em membranas de álcool polietileno-vinílico (PEVA), comparando o desempenho dos agentes quelantes (AQ) ácido iminodiacético (IDA), ácido aspártico carboximetilado (CM-Asp) e tris-2(aminoetil)amina (TREN) com íons metálicos imobilizados na purificação de anticorpos monoclonais anti-TNP, isotipo IgG1 a partir de sobrenadante de cultura celular precipitado e dialisado. Para determinar as melhores condições de adsorção e eluição na presença de diferentes sistemas tamponantes, foram testados os quelatos AQ-Ni2+, AQ-Zn2+ e AQ-Co2+, bem como os agentes quelantes sem metal imobilizado como grupos ionogênicos. De acordo com eletroforeses SDS-PAGE e análises ELlSA das frações dos picos de proteína obtidos, as melhores condições utilizadas para a purificação foi o uso de membranas PEVA-IDA-sem metal e PEVA-CM-Asp-Zn2+, em presença de tampão Tris-HCI 50 mM a pH 7,0 e eluição por aumento de concentração de Tris, atingindo fatores de purificação de 138,9 e 103,8 e pureza de 92,3% e 68,1%, respectivamente. A partir das isotermas de adsorção, determinou-se a capacidade máxima de adsorção e a constante de dissociação dos complexos IDA-lgG1 e CM-Asp-Zn2+ -lgG1 que, de acordo com o ajuste dos parâmetros pelo modelo de Langmuir, mostraram alta capacidade de adsorção e constantes de dissociação características de sistemas de afinidade média. Com o módulo de fibras ocas, construído em nosso laboratório, determinaram-se as curvas de ruptura por meio de experimentos de filtração para os processos propostos, e os resultados obtidos demonstraram que os sistemas de fibras ocas PEVA-IDA e PEVA-GM-Asp-Zn2+ são factíveis para a purificação de anticorpos monoclonais do isotipo IgG1 / Abstract: Monoclonal antibodies are immunoglobulins produced by normal, tumoral or hybrids Iymphocytes 8 obtained by hibridoma technology. Hybridomas are resulted from the fusion of Iymphocytes B with malignant myeloma cells which express both the Iymphocyte's property of specific-antibody production and the immortal characteristic of the myeloma cells. Monoclonal antibodies have been used in analytic and therapeutic areas. This application needs highly pure antibodies. Many techniques have been studied focusing monoclonal antibodies purification. These techniques include ion exchange, hydrophobic and affinity chromatography. In this study, we applied polyethylenevinyl alcohol (PEVA) membranes in the purification of monoclonal antibody from cel! culture supematant comparing the chelating agents Iminodiacetic Acid (IDA), Carboxy-methyl Aspartic Acid (CM-Asp) and Tris-2(aminoethyl)amine) (TREN) with different immobilized metal ios, Ni2+, Zn2+ and C02+, and with different buffers. We also evaluated the adsorption and purification of monoclonal antibodies using the chelating agents as ionogenic groups. According to SDS-PAGE electrophoresis and ELlSA analysis, the higher selectivity was obtained in the presence of 50 mM Tris-HCI buffer, pH 7,0 and with elution by increasing Tris concentration, with CM-Asp-Zn2+ and IDA as ionogenic group, which provided the purification of IgG with traces of albumin, reaching purification factors of 138.9 and 103.8 and purities of 92.3% and 68.1, respectively. The adsorbent capacity and the dissociation constant of the complexes IDA-lgG1 e CM-Asp-Zn2+ -lgG1 were determinate from adsorption isotherms. According to Langmuir model, the results indicated that the matrix presents high adsorption capacity and a dissociation constant characteristic for intermediate affinity systems. We also evaluated the breaktrough curves for the proposed processes. These breaktrough curves are important to scale up procedure / Mestrado / Desenvolvimento de Processos Biotecnologicos / Mestre em Engenharia Química
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/266218 |
Date | 07 November 2006 |
Creators | Bresolin, Igor Tadeu Lazzarotto |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Bueno, Sônia Maria Alves, 1961-, Bueno, Sonia Maria Alves, Zanin, Gisella Maria, Rosa, Paulo de Tarso Vieira e |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 106f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0028 seconds