Return to search

Modelos equivalentes de parques eólicos usando algoritmos genéticos

Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2014-01-13T19:22:30Z
No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ModelosEquivalentesParques.pdf: 4550764 bytes, checksum: ed39593ae09824f918f5a406f7bdeaa5 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2014-01-16T11:59:36Z (GMT) No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ModelosEquivalentesParques.pdf: 4550764 bytes, checksum: ed39593ae09824f918f5a406f7bdeaa5 (MD5) / Made available in DSpace on 2014-01-16T11:59:36Z (GMT). No. of bitstreams: 2
license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5)
Dissertacao_ModelosEquivalentesParques.pdf: 4550764 bytes, checksum: ed39593ae09824f918f5a406f7bdeaa5 (MD5)
Previous issue date: 2013 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Esta dissertação apresenta uma metodologia baseada em algoritmo genético (AG) para determinar modelos dinâmicos equivalentes de parques eólicos com geradores de indução em gaiola de esquilo ( GIGE) e geradores de indução duplamente alimentados ( GIDA), apresentando parâmetros elétricos e mecânicos distintos. A técnica se baseia em uma formulação multiobjetiva solucionada por um AG para minimizar os erros quadráticos das potências ativa e reativa entre modelo de um único gerador equivalente e o modelo do parque eólico investigado. A influência do modelo equivalente do parque eólico no comportamento dinâmico dos geradores síncronos é também investigada por meio do método proposto. A abordagem é testada em um parque eólico de 10MW composto por quatro turbinas eólicas ( 2x2MW e 2x3MW), consistindo alternadamente de geradores GIGE e GIDA interligados a uma barra infinita e posteriormente a rede elétrica do IEEE 14 barras. Os resultados obtidos pelo uso do modelo dinâmico detalhado para a representação do parque eólico são comparados aos do modelo equivalente proposto para avaliar a precisão e o custo computacional do modelo proposto. / This work presents a genetic algorithm-based methodology that determines aggregated dynamic models of both squirrel cage induction generator (SCIG) and double fed induction generator (DFIG), presenting different electrical and mechanical parameters. The technique is based on a multi-objective optimal formulation solved by a genetic algorithm to minimize the quadratic error of the active power and reactive power between flue equivalent single-generator model and the investigated wind farm. The influence of flue wind farm equivalent model on flue dynamic behavior of synchronous generators in flue power system, are also investigated by using the proposed method. The approach is tested on a 10MW wind farm consisting of 4 wind turbines (2 x 2MW and 2 x 3MW) when both SCIG and DFIG are alternately integrated on the infinite bus and IEEE 14-bus power system. The results obtained using the detailed dynamic model for the wind farm representation are compared against those obtained with flue proposed aggregated model to evaluate the accuracy and the computational cost of the proposed model.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/4606
Date11 September 2013
CreatorsMONTEIRO, Felipe
ContributorsVIEIRA, João Paulo Abreu, BEZERRA, Ubiratan Holanda
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds