Return to search

High power targets for cyclotron production of 99mTc‡

Introduction
Technetium-99m, supplied in the form of 99Mo/99mTc generators, is the most widely used radioisotope for nuclear medical imaging. The parent isotope 99Mo is currently produced in nuclear reactors. Recent disruptions in the 99Mo supply chain [1] prompted the development of methods for the direct accelerator-based production of 99mTc.
Our approach involves the 100Mo(p,2n)99mTc reaction on isotopically enriched molybdenum using small medical cyclotrons (Ep ≤ 20 MeV), which is a viable method for the production of clinically useful quantities of 99mTc [2].
Multi-Curie production of 99mTc requires a 100Mo target capable of dissipating high beam intensities [3]. We have reported the fabrication of 100Mo targets of both small and large area tar-gets by electrophoretic deposition and subsequent sintering [4]. As part of our efforts to further enhance the performance of molybdenum targets at high beam currents, we have developed a novel target system (initially de-signed for the GE PETtrace cyclotron) based on a pressed and sintered 100Mo plate brazed onto a dispersion-strengthened copper backing.

Materials and Methods
In the first step, a molybdenum plate is produced similarly to the method described in [5] by compacting approximately 1.5 g of commercially available 100Mo powder using a cylindrical tool of 20 mm diameter. A pressure between 25 kN/cm2 and 250 kN/cm2 is applied by means of a hydraulic press.
The pressed molybdenum plate is then sintered in a reducing atmosphere (Ar/2% H2) at 1,700 oC for five hours. The resulting 100Mo plates have about 90–95 % of the molybdenum bulk density.
The 100Mo plate is furnace brazed at ~750 oC onto a backing manufactured from a disperse on strengthened copper composite (e.g. Glidcop AL-15) using a high temperature silver-copper brazing filler.
This process yields a unique, mechanically and thermally robust target system for high beam power irradiation.
Irradiations were performed on the GE PETtrace cyclotrons at LHRI and CPDC with 16.5 MeV protons and beam currents ≥ 100 µA. Targets were visually inspected after a 6 hour, 130 µA bombardment (2.73 kW/cm2, average) and were found fully intact. Up to 4.7 Ci of 99mTc have been produced to date. The saturated production yield remained constant between 2 hour and 6 hour irradiations.

Results and Conclusion
These results demonstrate that our brazed tar-get assembly can withstand high beam intensities for long irradiations without deterioration. Efforts are currently underway to determine maximum performance parameters.

Identiferoai:union.ndltd.org:DRESDEN/oai:qucosa:de:qucosa:22270
Date January 2015
CreatorsZeisler, S. K., Hanemaayer, V., Buckley, K. R., Hook, B. K., MeDiarmid, S., Klug, J., Corsaut, J., Kovacs, M., Cockburn, N., Exonomou, C., Harper, R., Valliant, J. F., Ruth, T. J., Schaffer, P.
ContributorsTRIUMF, Vancouver BC, Canada
PublisherHelmholtz-Zentrum Dresden - Rossendorf
Source SetsHochschulschriftenserver (HSSS) der SLUB Dresden
LanguageEnglish
Detected LanguageEnglish
Typedoc-type:conferenceObject, info:eu-repo/semantics/conferenceObject, doc-type:Text
SourceWTTC15
Rightsinfo:eu-repo/semantics/openAccess
Relationurn:nbn:de:bsz:d120-qucosa-162048, qucosa:22221

Page generated in 0.0745 seconds