A Study of Deflagration To Detonation Transition In a Pulsed Detonation Engine

A Pulse Detonation Engine (PDE) is a propulsion device that takes advantage of the pressure rise inherent to the efficient burning of fuel-air mixtures via detonations. Detonation initiation is a critical process that occurs in the cycle of a PDE. A practical method of detonation initiation is Deflagration-to-Detonation Transition (DDT), which describes the transition of a subsonic deflagration, created using low initiation energies, to a supersonic detonation. This thesis presents the effects of obstacle spacing, blockage ratio, DDT section length, and airflow on DDT behavior in hydrogen-air and ethylene-air mixtures for a repeating PDE. These experiments were performed on a 2 diameter, 40 long, continuous-flow PDE located at the General Electric Global Research Center in Niskayuna, New York.

A fundamental study of experiments performed on a modular orifice plate DDT geometry revealed that all three factors tested (obstacle blockage ratio, length of DDT section, and spacing between obstacles) have a statistically significant effect on flame acceleration. All of the interactions between the factors, except for the interaction of the blockage ratio with the spacing between obstacles, were also significant. To better capture the non-linearity of the DDT process, further studies were performed using a clear detonation chamber and a high-speed digital camera to track the flame chemiluminescence as it progressed through the PDE.

Results show that the presence of excess obstacles, past what is minimally required to transition the flame to detonation, hinders the length and time to transition to detonation. Other key findings show that increasing the mass flow-rate of air through the PDE significantly reduces the run-up time of DDT, while having minimal effect on run-up distance. These experimental results provided validation runs for computational studies. In some cases as little as 20% difference was seen.

The minimum DDT length for 0.15 lb/s hydrogen-air studies was 8 L/D from the spark location, while for ethylene it was 16 L/D. It was also observed that increasing the airflow rate through the tube from 0.1 to 0.3 lbs/sec decreased the time required for DDT by 26%, from 3.9 ms to 2.9 ms.

Identiferoai:union.ndltd.org:GATECH/oai:smartech.gatech.edu:1853/7526
Date22 November 2005
CreatorsChapin, David Michael
PublisherGeorgia Institute of Technology
Source SetsGeorgia Tech Electronic Thesis and Dissertation Archive
Languageen_US
Detected LanguageEnglish
TypeThesis
Format2233903 bytes, application/pdf

Page generated in 0.0218 seconds