Planejamento da geração distribuida com foco na confiabilidade

Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-10-16T12:46:06Z
No. of bitstreams: 1
danielfioresibotelho.pdf: 2805489 bytes, checksum: 3d0b4a60f2a2f2cb7d26ea836254595a (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-10-16T14:35:42Z (GMT) No. of bitstreams: 1
danielfioresibotelho.pdf: 2805489 bytes, checksum: 3d0b4a60f2a2f2cb7d26ea836254595a (MD5) / Made available in DSpace on 2018-10-16T14:35:42Z (GMT). No. of bitstreams: 1
danielfioresibotelho.pdf: 2805489 bytes, checksum: 3d0b4a60f2a2f2cb7d26ea836254595a (MD5)
Previous issue date: 2018-08-31 / O presente trabalho apresenta uma metodologia para a alocação de unidades de Geração Distribuída no Sistema de Distribuição de Energia Elétrica visando a melhoria dos indicadores de confiabilidade da rede. O objetivo é avaliar qual o melhor ponto do sistema para realizar a inserção da unidade GD. Realiza-se também a análise de como essa alocação afeta os indicadores de qualidade e as perdas elétricas do sistema em estudo. A inclusão de limite para um indicador de qualidade considerado na distribuição de energia elétrica é explorada neste trabalho, verificando que a inserção de geração distribuída na rede pode fazer com que tal restrição seja atendida. A metodologia proposta é baseada nas técnicas meta-heurísticas Sistema Imunológico Artificial e Algoritmo Genético afim de comparar os resultados obtidos por ambas as técnicas. A função objetivo avaliada é composta por um somatório dos custos de confiabilidade, custos de investimento em geração distribuída e os custos das perdas elétricas do sistema; buscando assim sempre minimizar estes custos. Os algoritmos propostos são testados em sistemas conhecidos da literatura. / The present work presents a methodology for the allocation of Distributed Generation units in the Electric Energy Distribution System aiming at the improvement of network reliability indicators. The objective is to evaluate the best point of the system to perform the insertion of the GD unit. An analysis of how this allocation affects the quality indicators and the electrical losses of the system under study is also carried out. The inclusion of a limit for a quality indicator considered in the distribution of electric energy is explored in this work, verifying that the insertion of distributed generation in the network can cause that such restriction is met. The proposed methodology is based on the metaheuristic techniques Artificial Immune System and Genetic Algorithm in order to compare the results obtained by both techniques. The objective function evaluated is composed of a sum of the costs of reliability, costs of investment in distributed generation and the costs of the electrical losses of the system; always seeking to minimize these costs. The proposed algorithms are tested in systems known in the literature.

Identiferoai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/7901
Date31 August 2018
CreatorsBotelho, Daniel Fioresi
ContributorsOliveira, Leonardo Willer de, Dias, Bruno Henriques, Passos Filho, João Alberto, Ramos, Tales Pulinho
PublisherUniversidade Federal de Juiz de Fora (UFJF), Programa de Pós-graduação em Engenharia Elétrica, UFJF, Brasil, Faculdade de Engenharia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.003 seconds